Limit Switches OsiSense XC Standard – XCKS – Schneider Limit Switches
$ 40.94 – $ 49.45
SKU: N/A
Specifications
Main | ||||
Part Number | XCKS149 | XCKS102 | XCKS101 | XCKS131 |
Range of product | Telemecanique Limit switches XC Standard | Telemecanique Limit switches XC Standard | Telemecanique Limit switches XC Standard | Telemecanique Limit switches XC Standard |
Series name | Standard format | Standard format | Standard type | Standard type |
Product or component type | Limit switch | Limit switch | Limit switch | Limit switch |
device short name | XCKS | XCKS | XCKS | XCKS |
Sensor design | Form C conforming to CENELEC EN 50041 | Type B conforms to CENELEC EN 50041 | Type A conforms to CENELEC EN 50041 | |
body type | Fixed | Fixed | Fixed | Fixed |
Head type | Rotary head | Plunger head | Direct acting head | Swivel head |
Material | Plastic | Plastic | Plastic | Plastic |
Body material | Plastic | Plastic | Plastic | Plastic |
Head material | Plastic | Plastic | Plastic | Plastic |
Fixing mode | By the body | By the body | By ontology | By ontology |
Movement of operating head | Rotary | Linear | Linear | To rotate |
Type of operator | Spring return roller lever elastomer variable length, roller diameter 50 mm | Spring return roller plunger metal | Spring return direct acting metal | Spring Return Roller Rocker Thermoplastic |
Type of approach | Lateral approach, 1 or 2 programmable direction | Lateral approach, 2 directions | Vertical movement, one-way | Side movement, 1 or 2 directions programmable |
Cable entry | 1 entry tapped for Pg 13.5 cable gland, cable outer diameter: 9…12 mm | 1 entry tapped for Pg 13.5 cable gland, cable outer diameter: 9…12 mm | 1 cable gland suitable for Pg13.5, cable outer diameter: 9…12 mm | 1 cable gland suitable for Pg13.5, cable outer diameter: 9…12 mm |
Number of poles | 2 | 2 | 2 | 2 |
Contacts type and composition | 1 NC + 1 NO | 1 NC + 1 NO | 1 NC + 1 NO | 1 NC + 1 NO |
Contact operation | Snap action | Snap action | Momentary | Momentary |
Complementary | ||||
Switch actuation | By 30° cam | By 30° cam | The end | 30° lip |
Electrical connection | Screw-clamp terminals, clamping capacity: 1 x 0.34…2 x 1.5 mm² | Screw-clamp terminals, clamping capacity: 1 x 0.34…2 x 1.5 mm² | Screw clamp terminal, clamping capacity: 1 x 0.34…2 x 1.5 mm² | Screw clamp terminal, clamping capacity: 1 x 0.34…2 x 1.5 mm² |
Contacts insulation form | Zb | Zb | Zb | Zb |
Number of steps | 1 | 1 | 1 | 1 |
Positive opening | With | With | Have | Have |
Force open minimum torque | 0.15 Nm | |||
Minimum torque for tripping | 0.1 N.m | 0.1 Nm | ||
Minimum actuation speed | 0.01 m/min | 0.01 m/min | 0.01 m/min | 0.01 m/min |
Positive opening minimum force | 20 N | 30N | ||
Minimum force for tripping | 12 N | 15N | ||
Maximum actuation speed | 1.5 m/s | 0.5 m/s | 0.5 m/s | 1.5 m/s |
Repeatability | Trigger point is 0.05mm 1 million operating cycles | |||
Contact code designation | A300, AC-15 (Ue = 240 V), Ie = 3 A conforming to EN/IEC 60947-5-1 appendix A | A300, AC-15 (Ue = 240 V), Ie = 3 A conforming to EN/IEC 60947-5-1 appendix A | A300, AC-15 (Ue = 240 V), Ie = 3 A conforming to EN/IEC 60947-5-1 Appendix A | A300, AC-15 (Ue = 240 V), Ie = 3 A conforming to EN/IEC 60947-5-1 Appendix A |
Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN/IEC 60947-5-1 appendix A | Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN/IEC 60947-5-1 appendix A | Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN/IEC 60947-5 -1 Appendix A | Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN/IEC 60947-5 -1 Appendix A | |
[Ithe] conventional enclosed thermal current | 10 A AC | 10 A AC | 10A AC | 10A AC |
[Ui] rated insulation voltage | 300 V conforming to UL 508 | 300 V conforming to UL 508 | 300 V according to UL 508 | 300 V according to UL 508 |
500 V (pollution degree 3) conforming to IEC 60947-1 | 500 V (pollution degree 3) conforming to IEC 60947-1 | 500 V (pollution degree 3) according to IEC 60947-1 | 500 V (pollution degree 3) according to IEC 60947-1 | |
300 V conforming to CSA C22.2 No 14 | 300 V conforming to CSA C22.2 No 14 | 300 V according to CSA C22.2 No 14 | 300 V according to CSA C22.2 No 14 | |
Maximum resistance across terminals | 25 MOhm conforming to IEC 60255-7 category 3 | 25 MOhm conforming to IEC 60255-7 category 3 | 25 MΩ conforming to IEC 60255-7 Safety Class 3 | 25 MΩ conforming to IEC 60255-7 Safety Class 3 |
[Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60664 | 6 kV conforming to IEC 60664 | 6 kV according to IEC 60664 | 6 kV according to IEC 60664 |
6 kV conforming to IEC 60947-1 | 6 kV conforming to IEC 60947-1 | 6 kV according to IEC 60947-1 | 6 kV according to IEC 60947-1 | |
Short-circuit protection | 10 A cartridge fuse, type gG | 10 A cartridge fuse, type gG | 10 A fuse fuse, type gG | 10 A fuse fuse, type gG |
Electrical durability | 5000000 cycles, DC-13, inductive load type, 120 V, 4 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C | 5000000 cycles, DC-13, inductive load type, 120 V, 4 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C | 5000000 cycles, DC-13, inductive load Load type, 120 V, 4 W, operating rating <60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13, inductive | 5000000 cycles, DC-13, inductive load Load type, 120 V, 4 W, operating rating <60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13, inductive |
5000000 cycles, DC-13, inductive load type, 24 V, 10 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C | 5000000 cycles, DC-13, inductive load type, 24 V, 10 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C | load Type, 24 V, 10 W, operating rating<60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13, inductive | load Type, 24 V, 10 W, operating rating<60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13, inductive | |
5000000 cycles, DC-13, inductive load type, 48 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C | 5000000 cycles, DC-13, inductive load type, 48 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C | loadLoad type, 48 V, 7 W, operating rating Value <60 cycles/min, load factor: 0.5 conforming to IEC 60947-5-1 Annex C | loadLoad type, 48 V, 7 W, operating rating Value <60 cycles/min, load factor: 0.5 conforming to IEC 60947-5-1 Annex C | |
Mechanical durability | 20000000 cycles | 15000000 cycles | 25000000 times | 20000000 times |
Width | 50 mm | 40 mm | 40 mm | 40 mm |
Height | 133…188 mm | 117 mm | 104 mm | 130mm |
Depth | 65 mm | 37 mm | 37 mm | 60 mm |
Product weight | 0.18 kg | 0.133 kg | 0.125 kg | 0.16kg |
Terminals description ISO n°1 | (21-22)NC | (13-14)NO | (21-22)NC | (13-14)NO |
(13-14)NO | (21-22)NC | (13-14)NO | (21-22)NC | |
Environment | ||||
Shock resistance | 40 gn for 11 ms conforming to IEC 60068-2-27 | 40 gn for 11 ms conforming to IEC 60068-2-27 | 40 gn for 11 ms conforming to IEC 60068-2-27 | 40 gn for 11 ms conforming to IEC 60068-2-27 |
Vibration resistance | 20 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 | 25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 | 25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 | 25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 |
IP degree of protection | IP67 conforming to IEC 60529 | IP67 conforming to IEC 60529 | IP67 conforms to screwed | IP67 conforms to screwed |
IP66 conforming to IEC 60529 | IP66 conforming to IEC 60529 | IP66 conforms to screwed | IP66 conforms to screwed | |
IK degree of protection | IK05 conforming to EN 50102 | IK05 conforming to EN 50102 | IK05 conforms to EN 50102 | IK05 conforms to EN 50102 |
Electrical shock protection class | Class II conforming to IEC 61140 | Class II conforming to IEC 61140 | Class II conforms to IEC 61140 | Class II conforms to IEC 61140 |
Class II conforming to NF C 20-030 | Class II conforming to NF C 20-030 | Class II conforms to NF C 20-030 | Class II conforms to NF C 20-030 | |
Overvoltage category | Class II conforming to IEC 61140 | Class II conforming to IEC 61140 | Class II conforms to IEC 61140 | Class II conforms to IEC 61140 |
Class II conforming to NF C 20-030 | Class II conforming to NF C 20-030 | Class II conforms to NF C 20-030 | Class II conforms to NF C 20-030 | |
Ambient air temperature for operation | -25…70 °C | -25…70 °C | -25…70°C | -25…70°C |
Ambient air temperature for storage | -40…70 °C | -40…70 °C | -40…70°C | -40…70°C |
Protective treatment | TC | TC | TC | TC |
Product certifications | CSA | UL | CCC | UL |
UL | CCC | UL | CSA | |
CCC | CSA | CSA | CCC | |
Standards | EN 60204-1 | UL 508 | EN 60947-5-1 | IEC 60947-5-1 |
IEC 60947-5-1 | IEC 60947-5-1 | UL 508 | EN 60947-5-1 | |
UL 508 | CSA C22.2 No 14 | IEC 60204-1 | UL 508 | |
IEC 60204-1 | CENELEC EN 50041 | CSA C22.2 No 14 | CSA C22.2 No 14 | |
CENELEC EN 50041 | EN 60947-5-1 | CENELEC EN 50041 | CENELEC EN 50041 | |
CSA C22.2 No 14 | EN 60204-1 | EN 60204-1 | IEC 60204-1 | |
EN 60947-5-1 | IEC 60204-1 | IEC 60947-5-1 | EN 60204-1 | |
Packing Units | ||||
Unit Type of Package 1 | PCE | PCE | PCE | PCE |
Number of Units in Package 1 | 1 | 1 | 1 | 1 |
Package 1 Height | 5.000 cm | 4.0 cm | 4cm | 4.2 cm |
Package 1 Width | 9.000 cm | 6.0 cm | 6cm | 9.6cm |
Package 1 Length | 15.300 cm | 13.5 cm | 13.2 cm | 13.2 cm |
Package 1 Weight | 214.000 g | 150.0 g | 144g | 176.0g |
Unit Type of Package 2 | S02 | S02 | S02 | S02 |
Number of Units in Package 2 | 12 | 36 | 36 | Twenty two |
Package 2 Height | 15.000 cm | 15.0 cm | 15cm | 15.0cm |
Package 2 Width | 30.000 cm | 30.0 cm | 30cm | 30.0cm |
Package 2 Length | 40.000 cm | 40.0 cm | 40cm | 40.0cm |
Package 2 Weight | 3.010 kg | 5.923 kg | 5.603 kg | 4.364 kg |
Contractual warranty | ||||
Warranty | 18 months | 18 months | 18 months | 18 months |
Main information | |||
Part Number | XCKS131H29 | XCKS141 | XCKS159 |
Product Series | Telemecanique Limit switches XC Standard | Telemecanique Limit switches XC Standard | Telemecanique Limit switches XC Standard |
Serial Number | Standard type | Standard type | Standard type |
product type | Limit switch | Limit switch | Limit switch |
product short name | XCKS | XCKS | XCKS |
sensor design | Type A conforms to CENELEC EN 50041 | – | Form D conforms to CENELEC EN 50041 |
ontology type | Fixed | Fixed | Fixed |
Control head type | Swivel head | Swivel head | Swivel head |
Material | Plastic | Plastic | Plastic |
body material | Plastic | Plastic | Plastic |
head material | Plastic | Plastic | Plastic |
fixed mode | By ontology | By ontology | By ontology |
Operation head movement | To rotate | To rotate | To rotate |
Operating head type | Spring Return Roller Rocker Thermoplastic | Spring Return Roller Rocker Thermoplastic Variable Length | Spring Return, Round Rod Rocker Thermoplastic Round Rod 6 mm, L = 200 mm |
method type | Side movement, 1 or 2 directions programmable | Side movement, 1 or 2 directions programmable | Side movement, 1 or 2 directions programmable |
cable entry hole | 1 cable gland for M20x1.6, outer cable diameter: 7…13 mm | 1 cable gland suitable for Pg13.5, cable outer diameter: 9…12 mm | 1 cable gland suitable for Pg13.5, cable outer diameter: 9…12 mm |
number of poles | 2 | 2 | 2 |
contact type | 1 NC + 1 NO | 1 NC + 1 NO | 1 NC + 1 NO |
contact action | Momentary | Momentary | Momentary |
Additional information | |||
switch trigger | 30° lip | 30° lip | Any moving parts |
Electrical connections | Screw clamp terminal, clamping capacity: 1 x 0.34…2 x 1.5 mm² | Screw clamp terminal, clamping capacity: 1 x 0.34…2 x 1.5 mm² | Screw clamp terminal, clamping capacity: 1 x 0.34…2 x 1.5 mm² |
Type of contact wire insulation | Zb | Zb | Zb |
Step count | 1 | 1 | 1 |
force open | Have | Have | None |
Force open minimum torque | 0.15 Nm | ||
Minimum trigger torque | 0.1 Nm | 0.1 Nm | 0.1 Nm |
minimum braking speed | 0.01 m/min | 0.01 m/min | 0.01 m/min |
operating speed | 1.5 m/s | 1.5 m/s | 1 m/s |
Contact wire regulation grade | A300, AC-15 (Ue = 240 V), Ie = 3 A conforming to EN/IEC 60947-5-1 Appendix A | A300, AC-15 (Ue = 240 V), Ie = 3 A conforming to EN/IEC 60947-5-1 Appendix A | A300, AC-15 (Ue = 240 V), Ie = 3 A conforming to EN/IEC 60947-5-1 Appendix A |
Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN/IEC 60947-5 -1 Appendix A | Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN/IEC 60947-5 -1 Appendix A | Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN/IEC 60947-5 -1 Appendix A | |
Rated load current in case [Ithe] | 10A AC | 10A AC | 10A AC |
Rated insulation voltage [Ui] | 300 V according to UL 508 | 300 V according to UL 508 | 300 V according to UL 508 |
500 V (pollution degree 3) according to IEC 60947-1 | 500 V (pollution degree 3) according to IEC 60947-1 | 500 V (pollution degree 3) according to IEC 60947-1 | |
300 V according to CSA C22.2 No 14 | 300 V according to CSA C22.2 No 14 | 300 V according to CSA C22.2 No 14 | |
Maximum resistance across terminals | 25 MΩ conforming to IEC 60255-7 Safety Class 3 | 25 MΩ conforming to IEC 60255-7 Safety Class 3 | 25 MΩ conforming to IEC 60255-7 Safety Class 3 |
Rated impulse withstand voltage [Uimp] | 6 kV according to IEC 60664 | 6 kV according to IEC 60664 | 6 kV according to IEC 60664 |
6 kV according to IEC 60947-1 | 6 kV according to IEC 60947-1 | 6 kV according to IEC 60947-1 | |
Short circuit protection | 10 A fuse fuse, type gG | 10 A fuse fuse, type gG | 10 A fuse fuse, type gG |
Electrical life | 5000000 cycles, DC-13, inductive load Load type, 120 V, 4 W, operating rating <60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13, inductive | 5000000 cycles, DC-13, inductive load Load type, 120 V, 4 W, operating rating <60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13, inductive | 5000000 cycles, DC-13, inductive load Load type, 120 V, 4 W, operating rating <60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13, inductive |
load Type, 24 V, 10 W, operating rating<60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13, inductive | load Type, 24 V, 10 W, operating rating<60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13, inductive | load Type, 24 V, 10 W, Operating rating <60 cycles/min, Duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5,000,000 cycles, DC-13, | |
loadLoad type, 48 V, 7 W, operating rating Value <60 cycles/min, load factor: 0.5 conforming to IEC 60947-5-1 Annex C | loadLoad type, 48 V, 7 W, operating rating Value <60 cycles/min, load factor: 0.5 conforming to IEC 60947-5-1 Annex C | Inductive load Load type, 48 V, 7 W, Operating rating Value <60 cycles/min, load factor: 0.5 conforming to IEC 60947-5-1 Annex C | |
Mechanical life | 20000000 times | 20000000 times | 20000000 times |
width | 40 mm | 40 mm | 40 mm |
high | 130mm | 117…172mm | 98…280mm |
depth | 60 mm | 57 mm | 55 mm |
product weight | 0.16kg | 0.165 kg | 0.17 kg |
ISO n°1 terminals | (13-14)NO | (13-14)NO | (13-14)NO |
(21-22)NC | (21-22)NC | (21-22)NC | |
Environment | |||
impact resistance | 40 gn for 11 ms conforming to IEC 60068-2-27 | 40 gn for 11 ms conforming to IEC 60068-2-27 | 40 gn for 11 ms conforming to IEC 60068-2-27 |
Anti-vibration | 25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 | 25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 | 25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 |
IP protection class | IP67 conforms to screwed | IP67 conforms to screwed | IP67 conforms to screwed |
IP66 conforms to screwed | IP66 conforms to screwed | IP66 conforms to screwed | |
IK protection class | IK05 conforms to EN 50102 | IK05 conforms to EN 50102 | IK05 conforms to EN 50102 |
Electric Shock Protection Level | Class II conforms to IEC 61140 | Class II conforms to IEC 61140 | Class II conforms to IEC 61140 |
Class II conforms to NF C 20-030 | Class II conforms to NF C 20-030 | Class II conforms to NF C 20-030 | |
Type of overvoltage | Class II conforms to IEC 61140 | Class II conforms to IEC 61140 | Class II conforms to IEC 61140 |
Class II conforms to NF C 20-030 | Class II conforms to NF C 20-030 | Class II conforms to NF C 20-030 | |
operating temperature | -25…70°C | -25…70°C | -25…70°C |
storage environment temperature | -40…70°C | -40…70°C | -40…70°C |
Protective treatment | TC | TC | TC |
certified product | CCC | UL | CCC |
UL | CSA | CSA | |
CSA | CCC | UL | |
Standards compliant | EN 60204-1 | UL 508 | UL 508 |
CSA C22.2 No 14 | IEC 60204-1 | EN 60947-5-1 | |
IEC 60947-5-1 | EN 60947-5-1 | CSA C22.2 No 14 | |
EN 60947-5-1 | IEC 60947-5-1 | EN 60204-1 | |
UL 508 | CENELEC EN 50041 | CENELEC EN 50041 | |
IEC 60204-1 | EN 60204-1 | IEC 60947-5-1 | |
CENELEC EN 50041 | CSA C22.2 No 14 | IEC 60204-1 | |
Packaging unit | |||
Unit Type of Package 1 | PCE | PCE | PCE |
Number of Units in Package 1 | 1 | 1 | 1 |
Package 1 Height | 4.2 cm | 4.100 cm | 4.2 cm |
Package 1 Width | 9.4 cm | 9.600 cm | 5.8cm |
Package 1 Length | 12.8 cm | 13.200 cm | 20.8 cm |
Package 1 Weight | 176.0g | 186.000g | 184.0g |
Unit Type of Package 2 | S02 | S02 | S02 |
Number of Units in Package 2 | Twenty two | Twenty two | 18 |
Package 2 Height | 15.0cm | 15.000 cm | 15.0cm |
Package 2 Width | 30.0cm | 30.000 cm | 30.0cm |
Package 2 Length | 40.0cm | 40.000 cm | 40.0cm |
Package 2 Weight | 4.39kg | 4.626 kg | 3.825 kg |
Contract warranty | |||
Warranty | 18 months | 18 months | 18 months |
Weight | 0.18 kg |
---|---|
Dimensions | 6.5 × 5.0 × 18.8 cm |
Model | XCKS101, XCKS102, XCKS131, XCKS131H29, XCKS141, XCKS149, XCKS159 |
Related products
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details