$ 40.94 – $ 49.45Price range: $ 40.94 through $ 49.45
| Main | ||||
| Part Number | XCKS149 | XCKS102 | XCKS101 | XCKS131 |
| Range of product | Telemecanique Limit switches XC Standard | Telemecanique Limit switches XC Standard | Telemecanique Limit switches XC Standard | Telemecanique Limit switches XC Standard |
| Series name | Standard format | Standard format | Standard type | Standard type |
| Product or component type | Limit switch | Limit switch | Limit switch | Limit switch |
| device short name | XCKS | XCKS | XCKS | XCKS |
| Sensor design | Form C conforming to CENELEC EN 50041 | Type B conforms to CENELEC EN 50041 | Type A conforms to CENELEC EN 50041 | |
| body type | Fixed | Fixed | Fixed | Fixed |
| Head type | Rotary head | Plunger head | Direct acting head | Swivel head |
| Material | Plastic | Plastic | Plastic | Plastic |
| Body material | Plastic | Plastic | Plastic | Plastic |
| Head material | Plastic | Plastic | Plastic | Plastic |
| Fixing mode | By the body | By the body | By ontology | By ontology |
| Movement of operating head | Rotary | Linear | Linear | To rotate |
| Type of operator | Spring return roller lever elastomer variable length, roller diameter 50 mm | Spring return roller plunger metal | Spring return direct acting metal | Spring Return Roller Rocker Thermoplastic |
| Type of approach | Lateral approach, 1 or 2 programmable direction | Lateral approach, 2 directions | Vertical movement, one-way | Side movement, 1 or 2 directions programmable |
| Cable entry | 1 entry tapped for Pg 13.5 cable gland, cable outer diameter: 9…12 mm | 1 entry tapped for Pg 13.5 cable gland, cable outer diameter: 9…12 mm | 1 cable gland suitable for Pg13.5, cable outer diameter: 9…12 mm | 1 cable gland suitable for Pg13.5, cable outer diameter: 9…12 mm |
| Number of poles | 2 | 2 | 2 | 2 |
| Contacts type and composition | 1 NC + 1 NO | 1 NC + 1 NO | 1 NC + 1 NO | 1 NC + 1 NO |
| Contact operation | Snap action | Snap action | Momentary | Momentary |
| Complementary | ||||
| Switch actuation | By 30° cam | By 30° cam | The end | 30° lip |
| Electrical connection | Screw-clamp terminals, clamping capacity: 1 x 0.34…2 x 1.5 mm² | Screw-clamp terminals, clamping capacity: 1 x 0.34…2 x 1.5 mm² | Screw clamp terminal, clamping capacity: 1 x 0.34…2 x 1.5 mm² | Screw clamp terminal, clamping capacity: 1 x 0.34…2 x 1.5 mm² |
| Contacts insulation form | Zb | Zb | Zb | Zb |
| Number of steps | 1 | 1 | 1 | 1 |
| Positive opening | With | With | Have | Have |
| Force open minimum torque | 0.15 Nm | |||
| Minimum torque for tripping | 0.1 N.m | 0.1 Nm | ||
| Minimum actuation speed | 0.01 m/min | 0.01 m/min | 0.01 m/min | 0.01 m/min |
| Positive opening minimum force | 20 N | 30N | ||
| Minimum force for tripping | 12 N | 15N | ||
| Maximum actuation speed | 1.5 m/s | 0.5 m/s | 0.5 m/s | 1.5 m/s |
| Repeatability | Trigger point is 0.05mm 1 million operating cycles | |||
| Contact code designation | A300, AC-15 (Ue = 240 V), Ie = 3 A conforming to EN/IEC 60947-5-1 appendix A | A300, AC-15 (Ue = 240 V), Ie = 3 A conforming to EN/IEC 60947-5-1 appendix A | A300, AC-15 (Ue = 240 V), Ie = 3 A conforming to EN/IEC 60947-5-1 Appendix A | A300, AC-15 (Ue = 240 V), Ie = 3 A conforming to EN/IEC 60947-5-1 Appendix A |
| Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN/IEC 60947-5-1 appendix A | Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN/IEC 60947-5-1 appendix A | Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN/IEC 60947-5 -1 Appendix A | Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN/IEC 60947-5 -1 Appendix A | |
| [Ithe] conventional enclosed thermal current | 10 A AC | 10 A AC | 10A AC | 10A AC |
| [Ui] rated insulation voltage | 300 V conforming to UL 508 | 300 V conforming to UL 508 | 300 V according to UL 508 | 300 V according to UL 508 |
| 500 V (pollution degree 3) conforming to IEC 60947-1 | 500 V (pollution degree 3) conforming to IEC 60947-1 | 500 V (pollution degree 3) according to IEC 60947-1 | 500 V (pollution degree 3) according to IEC 60947-1 | |
| 300 V conforming to CSA C22.2 No 14 | 300 V conforming to CSA C22.2 No 14 | 300 V according to CSA C22.2 No 14 | 300 V according to CSA C22.2 No 14 | |
| Maximum resistance across terminals | 25 MOhm conforming to IEC 60255-7 category 3 | 25 MOhm conforming to IEC 60255-7 category 3 | 25 MΩ conforming to IEC 60255-7 Safety Class 3 | 25 MΩ conforming to IEC 60255-7 Safety Class 3 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60664 | 6 kV conforming to IEC 60664 | 6 kV according to IEC 60664 | 6 kV according to IEC 60664 |
| 6 kV conforming to IEC 60947-1 | 6 kV conforming to IEC 60947-1 | 6 kV according to IEC 60947-1 | 6 kV according to IEC 60947-1 | |
| Short-circuit protection | 10 A cartridge fuse, type gG | 10 A cartridge fuse, type gG | 10 A fuse fuse, type gG | 10 A fuse fuse, type gG |
| Electrical durability | 5000000 cycles, DC-13, inductive load type, 120 V, 4 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C | 5000000 cycles, DC-13, inductive load type, 120 V, 4 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C | 5000000 cycles, DC-13, inductive load Load type, 120 V, 4 W, operating rating <60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13, inductive | 5000000 cycles, DC-13, inductive load Load type, 120 V, 4 W, operating rating <60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13, inductive |
| 5000000 cycles, DC-13, inductive load type, 24 V, 10 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C | 5000000 cycles, DC-13, inductive load type, 24 V, 10 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C | load Type, 24 V, 10 W, operating rating<60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13, inductive | load Type, 24 V, 10 W, operating rating<60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13, inductive | |
| 5000000 cycles, DC-13, inductive load type, 48 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C | 5000000 cycles, DC-13, inductive load type, 48 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C | loadLoad type, 48 V, 7 W, operating rating Value <60 cycles/min, load factor: 0.5 conforming to IEC 60947-5-1 Annex C | loadLoad type, 48 V, 7 W, operating rating Value <60 cycles/min, load factor: 0.5 conforming to IEC 60947-5-1 Annex C | |
| Mechanical durability | 20000000 cycles | 15000000 cycles | 25000000 times | 20000000 times |
| Width | 50 mm | 40 mm | 40 mm | 40 mm |
| Height | 133…188 mm | 117 mm | 104 mm | 130mm |
| Depth | 65 mm | 37 mm | 37 mm | 60 mm |
| Product weight | 0.18 kg | 0.133 kg | 0.125 kg | 0.16kg |
| Terminals description ISO n°1 | (21-22)NC | (13-14)NO | (21-22)NC | (13-14)NO |
| (13-14)NO | (21-22)NC | (13-14)NO | (21-22)NC | |
| Environment | ||||
| Shock resistance | 40 gn for 11 ms conforming to IEC 60068-2-27 | 40 gn for 11 ms conforming to IEC 60068-2-27 | 40 gn for 11 ms conforming to IEC 60068-2-27 | 40 gn for 11 ms conforming to IEC 60068-2-27 |
| Vibration resistance | 20 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 | 25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 | 25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 | 25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 |
| IP degree of protection | IP67 conforming to IEC 60529 | IP67 conforming to IEC 60529 | IP67 conforms to screwed | IP67 conforms to screwed |
| IP66 conforming to IEC 60529 | IP66 conforming to IEC 60529 | IP66 conforms to screwed | IP66 conforms to screwed | |
| IK degree of protection | IK05 conforming to EN 50102 | IK05 conforming to EN 50102 | IK05 conforms to EN 50102 | IK05 conforms to EN 50102 |
| Electrical shock protection class | Class II conforming to IEC 61140 | Class II conforming to IEC 61140 | Class II conforms to IEC 61140 | Class II conforms to IEC 61140 |
| Class II conforming to NF C 20-030 | Class II conforming to NF C 20-030 | Class II conforms to NF C 20-030 | Class II conforms to NF C 20-030 | |
| Overvoltage category | Class II conforming to IEC 61140 | Class II conforming to IEC 61140 | Class II conforms to IEC 61140 | Class II conforms to IEC 61140 |
| Class II conforming to NF C 20-030 | Class II conforming to NF C 20-030 | Class II conforms to NF C 20-030 | Class II conforms to NF C 20-030 | |
| Ambient air temperature for operation | -25…70 °C | -25…70 °C | -25…70°C | -25…70°C |
| Ambient air temperature for storage | -40…70 °C | -40…70 °C | -40…70°C | -40…70°C |
| Protective treatment | TC | TC | TC | TC |
| Product certifications | CSA | UL | CCC | UL |
| UL | CCC | UL | CSA | |
| CCC | CSA | CSA | CCC | |
| Standards | EN 60204-1 | UL 508 | EN 60947-5-1 | IEC 60947-5-1 |
| IEC 60947-5-1 | IEC 60947-5-1 | UL 508 | EN 60947-5-1 | |
| UL 508 | CSA C22.2 No 14 | IEC 60204-1 | UL 508 | |
| IEC 60204-1 | CENELEC EN 50041 | CSA C22.2 No 14 | CSA C22.2 No 14 | |
| CENELEC EN 50041 | EN 60947-5-1 | CENELEC EN 50041 | CENELEC EN 50041 | |
| CSA C22.2 No 14 | EN 60204-1 | EN 60204-1 | IEC 60204-1 | |
| EN 60947-5-1 | IEC 60204-1 | IEC 60947-5-1 | EN 60204-1 | |
| Packing Units | ||||
| Unit Type of Package 1 | PCE | PCE | PCE | PCE |
| Number of Units in Package 1 | 1 | 1 | 1 | 1 |
| Package 1 Height | 5.000 cm | 4.0 cm | 4cm | 4.2 cm |
| Package 1 Width | 9.000 cm | 6.0 cm | 6cm | 9.6cm |
| Package 1 Length | 15.300 cm | 13.5 cm | 13.2 cm | 13.2 cm |
| Package 1 Weight | 214.000 g | 150.0 g | 144g | 176.0g |
| Unit Type of Package 2 | S02 | S02 | S02 | S02 |
| Number of Units in Package 2 | 12 | 36 | 36 | Twenty two |
| Package 2 Height | 15.000 cm | 15.0 cm | 15cm | 15.0cm |
| Package 2 Width | 30.000 cm | 30.0 cm | 30cm | 30.0cm |
| Package 2 Length | 40.000 cm | 40.0 cm | 40cm | 40.0cm |
| Package 2 Weight | 3.010 kg | 5.923 kg | 5.603 kg | 4.364 kg |
| Contractual warranty | ||||
| Warranty | 18 months | 18 months | 18 months | 18 months |
| Main information | |||
| Part Number | XCKS131H29 | XCKS141 | XCKS159 |
| Product Series | Telemecanique Limit switches XC Standard | Telemecanique Limit switches XC Standard | Telemecanique Limit switches XC Standard |
| Serial Number | Standard type | Standard type | Standard type |
| product type | Limit switch | Limit switch | Limit switch |
| product short name | XCKS | XCKS | XCKS |
| sensor design | Type A conforms to CENELEC EN 50041 | – | Form D conforms to CENELEC EN 50041 |
| ontology type | Fixed | Fixed | Fixed |
| Control head type | Swivel head | Swivel head | Swivel head |
| Material | Plastic | Plastic | Plastic |
| body material | Plastic | Plastic | Plastic |
| head material | Plastic | Plastic | Plastic |
| fixed mode | By ontology | By ontology | By ontology |
| Operation head movement | To rotate | To rotate | To rotate |
| Operating head type | Spring Return Roller Rocker Thermoplastic | Spring Return Roller Rocker Thermoplastic Variable Length | Spring Return, Round Rod Rocker Thermoplastic Round Rod 6 mm, L = 200 mm |
| method type | Side movement, 1 or 2 directions programmable | Side movement, 1 or 2 directions programmable | Side movement, 1 or 2 directions programmable |
| cable entry hole | 1 cable gland for M20x1.6, outer cable diameter: 7…13 mm | 1 cable gland suitable for Pg13.5, cable outer diameter: 9…12 mm | 1 cable gland suitable for Pg13.5, cable outer diameter: 9…12 mm |
| number of poles | 2 | 2 | 2 |
| contact type | 1 NC + 1 NO | 1 NC + 1 NO | 1 NC + 1 NO |
| contact action | Momentary | Momentary | Momentary |
| Additional information | |||
| switch trigger | 30° lip | 30° lip | Any moving parts |
| Electrical connections | Screw clamp terminal, clamping capacity: 1 x 0.34…2 x 1.5 mm² | Screw clamp terminal, clamping capacity: 1 x 0.34…2 x 1.5 mm² | Screw clamp terminal, clamping capacity: 1 x 0.34…2 x 1.5 mm² |
| Type of contact wire insulation | Zb | Zb | Zb |
| Step count | 1 | 1 | 1 |
| force open | Have | Have | None |
| Force open minimum torque | 0.15 Nm | ||
| Minimum trigger torque | 0.1 Nm | 0.1 Nm | 0.1 Nm |
| minimum braking speed | 0.01 m/min | 0.01 m/min | 0.01 m/min |
| operating speed | 1.5 m/s | 1.5 m/s | 1 m/s |
| Contact wire regulation grade | A300, AC-15 (Ue = 240 V), Ie = 3 A conforming to EN/IEC 60947-5-1 Appendix A | A300, AC-15 (Ue = 240 V), Ie = 3 A conforming to EN/IEC 60947-5-1 Appendix A | A300, AC-15 (Ue = 240 V), Ie = 3 A conforming to EN/IEC 60947-5-1 Appendix A |
| Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN/IEC 60947-5 -1 Appendix A | Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN/IEC 60947-5 -1 Appendix A | Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN/IEC 60947-5 -1 Appendix A | |
| Rated load current in case [Ithe] | 10A AC | 10A AC | 10A AC |
| Rated insulation voltage [Ui] | 300 V according to UL 508 | 300 V according to UL 508 | 300 V according to UL 508 |
| 500 V (pollution degree 3) according to IEC 60947-1 | 500 V (pollution degree 3) according to IEC 60947-1 | 500 V (pollution degree 3) according to IEC 60947-1 | |
| 300 V according to CSA C22.2 No 14 | 300 V according to CSA C22.2 No 14 | 300 V according to CSA C22.2 No 14 | |
| Maximum resistance across terminals | 25 MΩ conforming to IEC 60255-7 Safety Class 3 | 25 MΩ conforming to IEC 60255-7 Safety Class 3 | 25 MΩ conforming to IEC 60255-7 Safety Class 3 |
| Rated impulse withstand voltage [Uimp] | 6 kV according to IEC 60664 | 6 kV according to IEC 60664 | 6 kV according to IEC 60664 |
| 6 kV according to IEC 60947-1 | 6 kV according to IEC 60947-1 | 6 kV according to IEC 60947-1 | |
| Short circuit protection | 10 A fuse fuse, type gG | 10 A fuse fuse, type gG | 10 A fuse fuse, type gG |
| Electrical life | 5000000 cycles, DC-13, inductive load Load type, 120 V, 4 W, operating rating <60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13, inductive | 5000000 cycles, DC-13, inductive load Load type, 120 V, 4 W, operating rating <60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13, inductive | 5000000 cycles, DC-13, inductive load Load type, 120 V, 4 W, operating rating <60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13, inductive |
| load Type, 24 V, 10 W, operating rating<60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13, inductive | load Type, 24 V, 10 W, operating rating<60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13, inductive | load Type, 24 V, 10 W, Operating rating <60 cycles/min, Duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5,000,000 cycles, DC-13, | |
| loadLoad type, 48 V, 7 W, operating rating Value <60 cycles/min, load factor: 0.5 conforming to IEC 60947-5-1 Annex C | loadLoad type, 48 V, 7 W, operating rating Value <60 cycles/min, load factor: 0.5 conforming to IEC 60947-5-1 Annex C | Inductive load Load type, 48 V, 7 W, Operating rating Value <60 cycles/min, load factor: 0.5 conforming to IEC 60947-5-1 Annex C | |
| Mechanical life | 20000000 times | 20000000 times | 20000000 times |
| width | 40 mm | 40 mm | 40 mm |
| high | 130mm | 117…172mm | 98…280mm |
| depth | 60 mm | 57 mm | 55 mm |
| product weight | 0.16kg | 0.165 kg | 0.17 kg |
| ISO n°1 terminals | (13-14)NO | (13-14)NO | (13-14)NO |
| (21-22)NC | (21-22)NC | (21-22)NC | |
| Environment | |||
| impact resistance | 40 gn for 11 ms conforming to IEC 60068-2-27 | 40 gn for 11 ms conforming to IEC 60068-2-27 | 40 gn for 11 ms conforming to IEC 60068-2-27 |
| Anti-vibration | 25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 | 25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 | 25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 |
| IP protection class | IP67 conforms to screwed | IP67 conforms to screwed | IP67 conforms to screwed |
| IP66 conforms to screwed | IP66 conforms to screwed | IP66 conforms to screwed | |
| IK protection class | IK05 conforms to EN 50102 | IK05 conforms to EN 50102 | IK05 conforms to EN 50102 |
| Electric Shock Protection Level | Class II conforms to IEC 61140 | Class II conforms to IEC 61140 | Class II conforms to IEC 61140 |
| Class II conforms to NF C 20-030 | Class II conforms to NF C 20-030 | Class II conforms to NF C 20-030 | |
| Type of overvoltage | Class II conforms to IEC 61140 | Class II conforms to IEC 61140 | Class II conforms to IEC 61140 |
| Class II conforms to NF C 20-030 | Class II conforms to NF C 20-030 | Class II conforms to NF C 20-030 | |
| operating temperature | -25…70°C | -25…70°C | -25…70°C |
| storage environment temperature | -40…70°C | -40…70°C | -40…70°C |
| Protective treatment | TC | TC | TC |
| certified product | CCC | UL | CCC |
| UL | CSA | CSA | |
| CSA | CCC | UL | |
| Standards compliant | EN 60204-1 | UL 508 | UL 508 |
| CSA C22.2 No 14 | IEC 60204-1 | EN 60947-5-1 | |
| IEC 60947-5-1 | EN 60947-5-1 | CSA C22.2 No 14 | |
| EN 60947-5-1 | IEC 60947-5-1 | EN 60204-1 | |
| UL 508 | CENELEC EN 50041 | CENELEC EN 50041 | |
| IEC 60204-1 | EN 60204-1 | IEC 60947-5-1 | |
| CENELEC EN 50041 | CSA C22.2 No 14 | IEC 60204-1 | |
| Packaging unit | |||
| Unit Type of Package 1 | PCE | PCE | PCE |
| Number of Units in Package 1 | 1 | 1 | 1 |
| Package 1 Height | 4.2 cm | 4.100 cm | 4.2 cm |
| Package 1 Width | 9.4 cm | 9.600 cm | 5.8cm |
| Package 1 Length | 12.8 cm | 13.200 cm | 20.8 cm |
| Package 1 Weight | 176.0g | 186.000g | 184.0g |
| Unit Type of Package 2 | S02 | S02 | S02 |
| Number of Units in Package 2 | Twenty two | Twenty two | 18 |
| Package 2 Height | 15.0cm | 15.000 cm | 15.0cm |
| Package 2 Width | 30.0cm | 30.000 cm | 30.0cm |
| Package 2 Length | 40.0cm | 40.000 cm | 40.0cm |
| Package 2 Weight | 4.39kg | 4.626 kg | 3.825 kg |
| Contract warranty | |||
| Warranty | 18 months | 18 months | 18 months |