Limit Switches OsiSense XC Standard – XCKM – Schneider Limit Switches

$ 25.30$ 43.56

SKU: N/A

Specifications

Main
Part Number XCKM102H29 XCKM115 XCKM102H29C XCKM2023LC
Range of product Telemecanique Limit switches XC Standard Telemecanique Limit switches XC Standard Telemecanique Limit switches XC Standard Telemecanique Limit switches XC Standard
Series name Standard format Standard format Standard format Standard format
Product or component type Limit switch Limit switch Limit switch
device short name XCKM XCKM XCKM XCKM
body type Fixed Fixed Fixed
Head type Plunger head Rotary head Plunger head
Material Metal Metal Metal Metal
Body material Zamak Zamak Zamak Zamak
Fixing mode By the body By the body By the body By the body
Movement of operating head Linear Rotary Linear Linear
Type of operator Spring return roller plunger metal Spring return roller lever thermoplastic Spring return roller plunger metal
Type of approach Lateral approach, 2 directions Lateral approach, 2 directions Lateral approach, 2 directions
Cable entry 3 entries tapped for M20 x 1.5 cable gland, cable outer diameter: 7…13 mm 3 entries tapped for Pg 11 cable gland 3 entries tapped for M20 x 1.5 cable gland, cable outer diameter: 7…13 mm
Number of poles 2 2 2
Contacts type and composition 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO
Contact operation Snap action Snap action Snap action
Complementary
Switch actuation By 30° cam By 30° cam By 30° cam
Electrical connection Screw-clamp terminals, clamping capacity: 1 x 0.34…2 x 1.5 mm² Screw-clamp terminals, clamping capacity: 1 x 0.34…2 x 1.5 mm² Screw-clamp terminals, clamping capacity: 1 x 0.34…2 x 1.5 mm²
Contacts insulation form Zb Zb Zb
Number of steps 1 1 1 1
Positive opening With With With
Positive opening minimum force 36 N 0.25 N.m 36 N
Minimum force for tripping 12 N 0.1 N.m 12 N 12 N
Minimum actuation speed 0.01 m/min 0.01 m/min 0.01 m/min
Maximum actuation speed 0.5 m/s 1.5 m/s 0.5 m/s 0.5 m/s
Contact code designation A300, AC-15 (Ue = 240 V), Ie = 3 A conforming to EN/IEC 60947-5-1 appendix A A300, AC-15 (Ue = 240 V), Ie = 3 A conforming to EN/IEC 60947-5-1 appendix A A300, AC-15 (Ue = 240 V), Ie = 3 A conforming to EN/IEC 60947-5-1 appendix A
Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN/IEC 60947-5-1 appendix A Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN/IEC 60947-5-1 appendix A Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN/IEC 60947-5-1 appendix A
[Ithe] conventional enclosed thermal current 10 A AC 10 A AC 10 A AC
[Ui] rated insulation voltage 300 V conforming to UL 508 300 V conforming to UL 508 300 V conforming to UL 508
500 V (pollution degree 3) conforming to IEC 60947-1 500 V (pollution degree 3) conforming to IEC 60947-1 500 V (pollution degree 3) conforming to IEC 60947-1
300 V conforming to CSA C22.2 No 14 300 V conforming to CSA C22.2 No 14 300 V conforming to CSA C22.2 No 14
Maximum resistance across terminals 25 MOhm conforming to IEC 60255-7 category 3 25 MOhm conforming to IEC 60255-7 category 3 25 MOhm conforming to IEC 60255-7 category 3
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60664 6 kV conforming to IEC 60664 6 kV conforming to IEC 60664
6 kV conforming to IEC 60947-1 6 kV conforming to IEC 60947-1 6 kV conforming to IEC 60947-1
Short-circuit protection 10 A cartridge fuse, type gG 10 A cartridge fuse, type gG 10 A cartridge fuse, type gG
Electrical durability 5000000 cycles, DC-13, inductive load type, 120 V, 4 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles, DC-13, inductive load type, 120 V, 4 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles, DC-13, inductive load type, 120 V, 4 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13, inductive load type, 24 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles, DC-13, inductive load type, 24 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles, DC-13, inductive load type, 24 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13, inductive load type, 48 V, 10 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles, DC-13, inductive load type, 48 V, 10 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles, DC-13, inductive load type, 48 V, 10 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
Mechanical durability 20000000 cycles 15000000 cycles 20000000 cycles
Width 64 mm 64 mm 64 mm 64 mm
Height 64 mm 64 mm 64 mm 64 mm
Depth 30 mm 30 mm 30 mm 30 mm
Product weight 0.255 kg 0.28 kg 0.255 kg
Terminals description ISO n°1 (13-14)NO (21-22)NC (13-14)NO
(21-22)NC (13-14)NO (21-22)NC
Environment
Shock resistance 50 gn for 11 ms conforming to EN/IEC 60068-2-27 50 gn for 11 ms conforming to EN/IEC 60068-2-27 50 gn for 11 ms conforming to EN/IEC 60068-2-27
Vibration resistance 25 gn (f= 10…500 Hz) conforming to EN/IEC 60068-2-6 25 gn (f= 10…500 Hz) conforming to EN/IEC 60068-2-6 25 gn (f= 10…500 Hz) conforming to EN/IEC 60068-2-6
IP degree of protection IP66 conforming to EN/IEC 60529 IP66 conforming to EN/IEC 60529 IP66 conforming to EN/IEC 60529
IK degree of protection IK05 conforming to EN 50102 IK05 conforming to EN 50102 IK05 conforming to EN 50102
Electrical shock protection class Class I conforming to IEC 61140 Class I conforming to IEC 61140 Class I conforming to IEC 61140
Class I conforming to NF C 20-030 Class I conforming to NF C 20-030 Class I conforming to NF C 20-030
Ambient air temperature for operation -25…70 °C -25…70 °C -25…70 °C -25…70 °C
Ambient air temperature for storage -40…70 °C -40…70 °C -40…70 °C
Protective treatment TC TC TC
Product certifications CSA UL CCC
UL CSA
CCC CCC
Standards UL 508 EN 60204-1 CSA C22.2 No 14
CSA C22.2 No 14 IEC 60204-1 EN 60947-5-1
EN 60204-1 CSA C22.2 No 14 UL 508
EN 60947-5-1 UL 508 EN 60204-1
IEC 60204-1 EN 60947-5-1 IEC 60204-1
IEC 60947-5-1 IEC 60947-5-1 IEC 60947-5-1
Packing Units
Unit Type of Package 1 PCE PCE PCE PCE
Number of Units in Package 1 1 1 1 1
Package 1 Height 3.3 cm 3.4 cm 14.6 cm 3.283 cm
Package 1 Width 6.6 cm 6.7 cm 3.2 cm 6.466 cm
Package 1 Length 14.99 cm 15.0 cm 6.4 cm 12.604 cm
Package 1 Weight 0.27 kg 315.0 g 261.5 g 0.301 kg
Unit Type of Package 2 S02 S02 P06 S02
Number of Units in Package 2 27 27 128 36
Package 2 Height 15 cm 15.0 cm 75.0 cm 15.0 cm
Package 2 Width 30 cm 30.0 cm 60.0 cm 30.0 cm
Package 2 Length 40 cm 40.0 cm 80.0 cm 40.0 cm
Package 2 Weight 7.83 kg 8.956 kg 49.744 kg 11.521 kg
P06 S02 PAL
432 8 576
77.0 cm 15.0 cm 75.0 cm
80.0 cm 30.0 cm 60.0 cm
60.0 cm 40.0 cm 80.0 cm
154.02 kg 2.484 kg 192848.0 g
Contractual warranty
Warranty 18 months 18 months

 

 

main information
Part Number XCKM2123LC
Product Series Telemecanique Limit switches XC Standard
Serial Number Standard type
product short name XCKM
Material Metal
body material Zamak
fixed mode By ontology
Operation head movement Linear
Additional information
Step count 1
Minimum trip force 15N
operating speed 0.5 m/s
width 64 mm
high 64 mm
depth 30 mm
Environment
operating temperature -25…70°C
Standards compliant
Packaging unit
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 3.289 cm
Package 1 Width 6.457 cm
Package 1 Length 12.663 cm
Package 1 Weight 311.0g
Unit Type of Package 2 S02
Number of Units in Package 2 36
Package 2 Height 15.0cm
Package 2 Width 30.0cm
Package 2 Length 40.0cm
Package 2 Weight 11.511kg
Unit Type of Package 3 P06
Number of Units in Package 3 576
Package 3 Height 75.0cm
Package 3 Width 60.0cm
Package 3 Length 80.0cm
Package 3 Weight 194.176kg
Contract warranty
Warranty 18 months

 

Weight N/A
Dimensions N/A
Model

XCKM102H29, XCKM102H29C, XCKM115, XCKM2023LC, XCKM2123LC

Related products