Specifications

Main
Part Number XCKT2102P16 XCKT2111P16 XCKT2110P16
Range of product Telemecanique Limit switches XC Standard Telemecanique Limit switches XC Standard Telemecanique Limit switches XC Standard
Series name Standard format Standard format Standard format
Product or component type Limit switch Limit switch Limit switch
device short name XCKT XCKT XCKT
Sensor design Compact form C conforming to CENELEC EN 50047 Compact Compact form B conforming to CENELEC EN 50047
body type Fixed Fixed Fixed
Head type Plunger head Plunger head Plunger head
Material Plastic Plastic Plastic
Body material Plastic Plastic Plastic
Head material Zamak Zamak Zamak
Fixing mode By the body By the body By the body
Movement of operating head Linear Linear Linear
Type of operator Spring return roller plunger metal Spring return roller plunger metal with nitrile boot Spring return plunger metal
Type of approach Lateral approach, 2 directions Vertical approach, 1 direction Vertical approach, 1 direction
Number of poles 2 2 2
Contacts type and composition 1 NC + 1 NO 1 NC + 1 NO 1 NC + 1 NO
Contact operation Snap action Snap action Snap action
Complementary
Switch actuation By 30° cam On end On end
Electrical connection Screw-clamp terminals, clamping capacity: 1 x 0.34…2 x 1.5 mm² Screw-clamp terminals, clamping capacity: 1 x 0.34…2 x 1.5 mm² Screw-clamp terminals, clamping capacity: 1 x 0.34…2 x 1.5 mm²
Cable entry 2 entries tapped for M16 x 1.5 cable gland, cable outer diameter: 4…8 mm 2 entries tapped for M16 x 1.5 cable gland, cable outer diameter: 4…8 mm 2 entries tapped for M16 x 1.5 cable gland, cable outer diameter: 4…8 mm
Contacts insulation form Zb Zb Zb
Positive opening With With With
Positive opening minimum force 36 N 45 N 45 N
Minimum force for tripping 12 N 15 N 15 N
Maximum actuation speed 0.5 m/s 0.01 m/min 0.01 m/min
Repeat accuracy 0.1 mm on the tripping points with 1 million operating cycles 0.5 m/s 0.5 m/s
Contact code designation A300, AC-15 (Ue = 240 V), Ie = 3 A, Ithe = 10 A conforming to EN/IEC 60947-5-1 appendix A 0.1 mm on the tripping points with 1 million operating cycles 0.1 mm on the tripping points with 1 million operating cycles
Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN/IEC 60947-5-1 appendix A A300, AC-15 (Ue = 240 V), Ie = 3 A, Ithe = 10 A conforming to EN/IEC 60947-5-1 appendix A A300, AC-15 (Ue = 240 V), Ie = 3 A, Ithe = 10 A conforming to EN/IEC 60947-5-1 appendix A
[Ui] rated insulation voltage 300 V conforming to UL 508 Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN/IEC 60947-5-1 appendix A Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN/IEC 60947-5-1 appendix A
500 V (pollution degree 3) conforming to IEC 60947-1 300 V conforming to UL 508 300 V conforming to UL 508
300 V conforming to CSA C22.2 No 14 500 V (pollution degree 3) conforming to IEC 60947-1 500 V (pollution degree 3) conforming to IEC 60947-1
Maximum resistance across terminals 25 MOhm conforming to IEC 60255-7 category 3 300 V conforming to CSA C22.2 No 14 300 V conforming to CSA C22.2 No 14
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60664 25 MOhm conforming to IEC 60255-7 category 3 25 MOhm conforming to IEC 60255-7 category 3
6 kV conforming to IEC 60947-1 6 kV conforming to IEC 60664 6 kV conforming to IEC 60664
Short-circuit protection 10 A cartridge fuse, type gG 6 kV conforming to IEC 60947-1 6 kV conforming to IEC 60947-1
Electrical durability 5000000 cycles, DC-13, 120 V, 4 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 10 A cartridge fuse, type gG 10 A cartridge fuse, type gG
5000000 cycles, DC-13, 24 V, 10 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles, DC-13, 120 V, 4 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles, DC-13, 120 V, 4 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13, 48 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles, DC-13, 24 V, 10 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles, DC-13, 24 V, 10 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13, 48 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles, DC-13, 48 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
Mechanical durability 10000000 cycles 15000000 cycles 15000000 cycles
Width 58 mm 58 mm 58 mm
Height 51 mm 51 mm 51 mm
Depth 30 mm 30 mm 30 mm
Product weight 0.105 kg 0.1 kg 0.1 kg
Terminals description ISO n°1 (21-22)NC (13-14)NO (21-22)NC
(13-14)NO (21-22)NC (13-14)NO
Environment
Shock resistance 50 gn for 11 ms conforming to IEC 60068-2-27 50 gn for 11 ms conforming to IEC 60068-2-27 50 gn for 11 ms conforming to IEC 60068-2-27
Vibration resistance 25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
IP degree of protection IP66 conforming to IEC 60529 IP66 conforming to IEC 60529 IP66 conforming to IEC 60529
IP67 conforming to IEC 60529 IP67 conforming to IEC 60529 IP67 conforming to IEC 60529
IK degree of protection IK04 conforming to EN 50102 IK04 conforming to EN 50102 IK04 conforming to EN 50102
Electrical shock protection class Class II conforming to IEC 61140 Class II conforming to IEC 61140 Class II conforming to IEC 61140
Class II conforming to NF C 20-030 Class II conforming to NF C 20-030 Class II conforming to NF C 20-030
Ambient air temperature for operation -25…70 °C -25…70 °C -25…70 °C
Ambient air temperature for storage -40…70 °C -40…70 °C -40…70 °C
Protective treatment TC TC TC
Product certifications CSA UL CCC
UL CSA CSA
CCC CCC UL
Standards UL 508 UL 508 EN/IEC 60947-5-1
EN/IEC 60204-1 EN/IEC 60204-1 UL 508
EN/IEC 60947-5-1 CSA C22.2 No 14 EN/IEC 60204-1
CSA C22.2 No 14 EN/IEC 60947-5-1 CSA C22.2 No 14
Packing Units
Unit Type of Package 1 PCE PCE PCE
Number of Units in Package 1 1 1 1
Package 1 Height 3.3 cm 3.4 cm 3.3 cm
Package 1 Width 6.4 cm 6.5 cm 6.4 cm
Package 1 Length 9.8 cm 10.0 cm 9.8 cm
Package 1 Weight 95.0 g 92.0 g 88 g
Unit Type of Package 2 S02 S02 S02
Number of Units in Package 2 58 50 58
Package 2 Height 15.0 cm 15.0 cm 15 cm
Package 2 Width 30.0 cm 30.0 cm 30 cm
Package 2 Length 40.0 cm 40.0 cm 40 cm
Package 2 Weight 6.005 kg 5.001 kg 5.6 kg
Contractual warranty
Warranty 18 months 18 months 18 months

Weight N/A
Dimensions N/A
Model

XCKT2102P16, XCKT2110P16, XCKT2111P16