Limit Switches OsiSense XC Standard – XCKT – Schneider Limit Switches
$ 42.24 – $ 43.56
SKU: N/A
Specifications
Main | |||
Part Number | XCKT2102P16 | XCKT2111P16 | XCKT2110P16 |
Range of product | Telemecanique Limit switches XC Standard | Telemecanique Limit switches XC Standard | Telemecanique Limit switches XC Standard |
Series name | Standard format | Standard format | Standard format |
Product or component type | Limit switch | Limit switch | Limit switch |
device short name | XCKT | XCKT | XCKT |
Sensor design | Compact form C conforming to CENELEC EN 50047 | Compact | Compact form B conforming to CENELEC EN 50047 |
body type | Fixed | Fixed | Fixed |
Head type | Plunger head | Plunger head | Plunger head |
Material | Plastic | Plastic | Plastic |
Body material | Plastic | Plastic | Plastic |
Head material | Zamak | Zamak | Zamak |
Fixing mode | By the body | By the body | By the body |
Movement of operating head | Linear | Linear | Linear |
Type of operator | Spring return roller plunger metal | Spring return roller plunger metal with nitrile boot | Spring return plunger metal |
Type of approach | Lateral approach, 2 directions | Vertical approach, 1 direction | Vertical approach, 1 direction |
Number of poles | 2 | 2 | 2 |
Contacts type and composition | 1 NC + 1 NO | 1 NC + 1 NO | 1 NC + 1 NO |
Contact operation | Snap action | Snap action | Snap action |
Complementary | |||
Switch actuation | By 30° cam | On end | On end |
Electrical connection | Screw-clamp terminals, clamping capacity: 1 x 0.34…2 x 1.5 mm² | Screw-clamp terminals, clamping capacity: 1 x 0.34…2 x 1.5 mm² | Screw-clamp terminals, clamping capacity: 1 x 0.34…2 x 1.5 mm² |
Cable entry | 2 entries tapped for M16 x 1.5 cable gland, cable outer diameter: 4…8 mm | 2 entries tapped for M16 x 1.5 cable gland, cable outer diameter: 4…8 mm | 2 entries tapped for M16 x 1.5 cable gland, cable outer diameter: 4…8 mm |
Contacts insulation form | Zb | Zb | Zb |
Positive opening | With | With | With |
Positive opening minimum force | 36 N | 45 N | 45 N |
Minimum force for tripping | 12 N | 15 N | 15 N |
Maximum actuation speed | 0.5 m/s | 0.01 m/min | 0.01 m/min |
Repeat accuracy | 0.1 mm on the tripping points with 1 million operating cycles | 0.5 m/s | 0.5 m/s |
Contact code designation | A300, AC-15 (Ue = 240 V), Ie = 3 A, Ithe = 10 A conforming to EN/IEC 60947-5-1 appendix A | 0.1 mm on the tripping points with 1 million operating cycles | 0.1 mm on the tripping points with 1 million operating cycles |
Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN/IEC 60947-5-1 appendix A | A300, AC-15 (Ue = 240 V), Ie = 3 A, Ithe = 10 A conforming to EN/IEC 60947-5-1 appendix A | A300, AC-15 (Ue = 240 V), Ie = 3 A, Ithe = 10 A conforming to EN/IEC 60947-5-1 appendix A | |
[Ui] rated insulation voltage | 300 V conforming to UL 508 | Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN/IEC 60947-5-1 appendix A | Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN/IEC 60947-5-1 appendix A |
500 V (pollution degree 3) conforming to IEC 60947-1 | 300 V conforming to UL 508 | 300 V conforming to UL 508 | |
300 V conforming to CSA C22.2 No 14 | 500 V (pollution degree 3) conforming to IEC 60947-1 | 500 V (pollution degree 3) conforming to IEC 60947-1 | |
Maximum resistance across terminals | 25 MOhm conforming to IEC 60255-7 category 3 | 300 V conforming to CSA C22.2 No 14 | 300 V conforming to CSA C22.2 No 14 |
[Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60664 | 25 MOhm conforming to IEC 60255-7 category 3 | 25 MOhm conforming to IEC 60255-7 category 3 |
6 kV conforming to IEC 60947-1 | 6 kV conforming to IEC 60664 | 6 kV conforming to IEC 60664 | |
Short-circuit protection | 10 A cartridge fuse, type gG | 6 kV conforming to IEC 60947-1 | 6 kV conforming to IEC 60947-1 |
Electrical durability | 5000000 cycles, DC-13, 120 V, 4 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C | 10 A cartridge fuse, type gG | 10 A cartridge fuse, type gG |
5000000 cycles, DC-13, 24 V, 10 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C | 5000000 cycles, DC-13, 120 V, 4 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C | 5000000 cycles, DC-13, 120 V, 4 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C | |
5000000 cycles, DC-13, 48 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C | 5000000 cycles, DC-13, 24 V, 10 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C | 5000000 cycles, DC-13, 24 V, 10 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C | |
5000000 cycles, DC-13, 48 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C | 5000000 cycles, DC-13, 48 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C | ||
Mechanical durability | 10000000 cycles | 15000000 cycles | 15000000 cycles |
Width | 58 mm | 58 mm | 58 mm |
Height | 51 mm | 51 mm | 51 mm |
Depth | 30 mm | 30 mm | 30 mm |
Product weight | 0.105 kg | 0.1 kg | 0.1 kg |
Terminals description ISO n°1 | (21-22)NC | (13-14)NO | (21-22)NC |
(13-14)NO | (21-22)NC | (13-14)NO | |
Environment | |||
Shock resistance | 50 gn for 11 ms conforming to IEC 60068-2-27 | 50 gn for 11 ms conforming to IEC 60068-2-27 | 50 gn for 11 ms conforming to IEC 60068-2-27 |
Vibration resistance | 25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 | 25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 | 25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 |
IP degree of protection | IP66 conforming to IEC 60529 | IP66 conforming to IEC 60529 | IP66 conforming to IEC 60529 |
IP67 conforming to IEC 60529 | IP67 conforming to IEC 60529 | IP67 conforming to IEC 60529 | |
IK degree of protection | IK04 conforming to EN 50102 | IK04 conforming to EN 50102 | IK04 conforming to EN 50102 |
Electrical shock protection class | Class II conforming to IEC 61140 | Class II conforming to IEC 61140 | Class II conforming to IEC 61140 |
Class II conforming to NF C 20-030 | Class II conforming to NF C 20-030 | Class II conforming to NF C 20-030 | |
Ambient air temperature for operation | -25…70 °C | -25…70 °C | -25…70 °C |
Ambient air temperature for storage | -40…70 °C | -40…70 °C | -40…70 °C |
Protective treatment | TC | TC | TC |
Product certifications | CSA | UL | CCC |
UL | CSA | CSA | |
CCC | CCC | UL | |
Standards | UL 508 | UL 508 | EN/IEC 60947-5-1 |
EN/IEC 60204-1 | EN/IEC 60204-1 | UL 508 | |
EN/IEC 60947-5-1 | CSA C22.2 No 14 | EN/IEC 60204-1 | |
CSA C22.2 No 14 | EN/IEC 60947-5-1 | CSA C22.2 No 14 | |
Packing Units | |||
Unit Type of Package 1 | PCE | PCE | PCE |
Number of Units in Package 1 | 1 | 1 | 1 |
Package 1 Height | 3.3 cm | 3.4 cm | 3.3 cm |
Package 1 Width | 6.4 cm | 6.5 cm | 6.4 cm |
Package 1 Length | 9.8 cm | 10.0 cm | 9.8 cm |
Package 1 Weight | 95.0 g | 92.0 g | 88 g |
Unit Type of Package 2 | S02 | S02 | S02 |
Number of Units in Package 2 | 58 | 50 | 58 |
Package 2 Height | 15.0 cm | 15.0 cm | 15 cm |
Package 2 Width | 30.0 cm | 30.0 cm | 30 cm |
Package 2 Length | 40.0 cm | 40.0 cm | 40 cm |
Package 2 Weight | 6.005 kg | 5.001 kg | 5.6 kg |
Contractual warranty | |||
Warranty | 18 months | 18 months | 18 months |
Weight | N/A |
---|---|
Dimensions | N/A |
Model | XCKT2102P16, XCKT2110P16, XCKT2111P16 |
Related products
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details