$ 13.34 – $ 67.62Price range: $ 13.34 through $ 67.62
| Designation | Model No. | Description | |
|---|---|---|---|
| Expansion lens (Note 1)  | 
FX-LE1 | ![]()  | 
Increases the sensing range by 5 times or more. ・ Ambient temperature: -60 to +350 ℃ -76 to +662 ℉ (Note 2) ・ Beam dia: ø3.6 mm ø0.142 in Sensing range (mm in) [Lens on both sides]  | 
| Super-expansion lens (Note 1)  | 
FX-LE2 | ![]()  | 
Tremendously increases the sensing range with large diameter lenses. ・ Ambient temperature: -60 to +350 ℃ -76 to +662 ℉ (Note 2) ・ Beam dia: ø9.8 mm ø0.386 in Sensing range (mm in) [Lens on both sides]  | 
| Side-view lens | FX-SV1 | ![]()  | 
Beam axis is bent by 90°. ・ Ambient temperature: -60 to +300 ℃ -76 to +572 ℉ (Note 4) ・ Beam dia: ø2.8 mm ø0.110 in Sensing range (mm in) [Lens on both sides]  | 
| (Note 1): | Be careful sure to use it only after you have adjusted it sufficiently when installing the thru-beam type fiber equipped with the expansion lens, as the beam envelope becomes narrow and alignment is difficult. | 
|---|---|
| (Note 2): | Refer to “Fiber page” for the ambient temperature of fibers to be used in combination. | 
| Amplifiers | FX-500 series (Upper value) FX-550 / FX-550L series (Lower value)  | 
FX-100 series | ||||||
|---|---|---|---|---|---|---|---|---|
| Mode | HYPR | U-LG | LONG | STD | FAST | H-SP | FX-101 | FX-102 | 
| FT-43 | 3,600 (Note 1) 3,600 (Note 1)  | 
3,600 (Note 1) 3,600 (Note 1)  | 
3,600 (Note 1) 3,600 (Note 1)  | 
3,600 (Note 1) 3,600 (Note 1)  | 
3,600 (Note 1) 3,600 (Note 1)  | 
1,600 –  | 
2,400 | 3,600 (Note 1)  | 
| FT-42 FT-42W  | 
3,600 (Note 1) 3,600 (Note 1)  | 
3,600 (Note 1) 3,600 (Note 1)  | 
3,600 (Note 1) 3,600 (Note 1)  | 
3,600 (Note 1) 3,600 (Note 1)  | 
3,600 (Note 1) 3,600 (Note 1)  | 
2,200 –  | 
3,400 | 3,600 (Note 1)  | 
| FT-45X | 1,600 (Note 1) 1,600 (Note 1)  | 
1,600 (Note 1) 1,600 (Note 1)  | 
1,600 (Note 1) 1,600 (Note 1)  | 
1,600 (Note 1) 1,600 (Note 1)  | 
1,600 (Note 1) 1,600 (Note 1)  | 
1,500 –  | 
1,600 (Note 1)  | 
1,600 (Note 1)  | 
| FT-R40 | 3,600 (Note 1) 3,600 (Note 1)  | 
3,600 (Note 1) 3,600 (Note 1)  | 
3,600 (Note 1) 3,600 (Note 1)  | 
3,600 (Note 1) 3,600 (Note 1)  | 
3,600 (Note 1) 3,600 (Note 1)  | 
1,900 –  | 
3,100 | 3,600 (Note 1)  | 
| FT-R43 FT-R44Y  | 
3,600 (Note 1) 3,600 (Note 1)  | 
3,600 (Note 1) 3,600 (Note 1)  | 
3,600 (Note 1) 3,600 (Note 1)  | 
3,600 (Note 1) 3,600 (Note 1)  | 
1,900 1,600 (Note 1)  | 
670 –  | 
1,300 | 3,600 (Note 1)  | 
| FT-H35-M2 | 3,600 (Note 1) 3,600 (Note 1)  | 
3,600 (Note 1) 3,600 (Note 1)  | 
3,600 (Note 1) 3,600 (Note 1)  | 
3,600 (Note 1) 3,600 (Note 1)  | 
3,300 3,600 (Note 1)  | 
1,400 –  | 
2,000 | 3,500 (Note 1)  | 
| FT-H20W-M1 | 1,600 (Note 1) 1,600 (Note 1)  | 
1,600 (Note 1) 1,600 (Note 1)  | 
1,600 (Note 1) 1,600 (Note 1)  | 
1,600 (Note 1) 1,600 (Note 1)  | 
1,600 (Note 1) 1,600 (Note 1)  | 
850 –  | 
1,300 | 1,600 (Note 1)  | 
| FT-H20-M1 | 1,600 (Note 1) 1,600 (Note 1)  | 
1,600 (Note 1) 1,600 (Note 1)  | 
1,600 (Note 1) 1,600 (Note 1)  | 
1,600 (Note 1) 1,600 (Note 1)  | 
1,600 (Note 1) 1,600 (Note 1)  | 
1,200 –  | 
1,600 (Note 1)  | 
1,600 (Note 1)  | 
| FT-H20-J50-S FT-H20-J30-S FT-H20-J20-S  | 
3,600 (Note 1) 3,600 (Note 1)  | 
3,600 (Note 1) 3,600 (Note 1)  | 
3,500 3,600 (Note 1)  | 
2,000 3,600 (Note 1)  | 
1,600 3,600 (Note 1)  | 
500 –  | 
1,000 | 3,500 (Note 1)  | 
| (Note 1): | The fiber cable length practically limits the sensing range. | 
|---|