KTM-MN31181P Contrast Sensors – SICK Sensor
$ 176.88
SKU: SICK 1071947
SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.
Part Number: 1071947
Contrast Sensor Model: KTM-MN31181P
OEM Spec Ref
Features
Dimensions (W x H x D) | 12 mm x 31.5 mm x 21 mm |
Sensing distance | 12.5 mm |
Sensing distance tolerance | ± 3 mm |
Housing design (light emission) | Small |
Light source | LED, white 1) |
Light emission | Long side of housing |
Light spot size | Ø 2 mm (12.5 mm) |
Light spot direction | Round |
Receiving filters | None |
Adjustment | Teach-in button |
Teach-in mode | 2-point teach-in static/dynamic + proximity to mark ET: Teach-in dynamic |
- 1) Average service life: 100,000 h at TU = +25 °C.
Mechanics/electronics
Supply voltage | 12 V DC … 24 V DC 1) |
Ripple | ≤ 5 Vpp 2) |
Current consumption | < 50 mA 3) |
Switching frequency | 15 kHz 4) |
Response time | 32 µs 5) |
Jitter | 15 µs |
Switching output | NPN |
Switching output (voltage) | NPN: HIGH = approx. UV / LOW ≤ 2 V |
Switching mode | Light/dark switching |
Output current Imax. | 50 mA 6) |
Input, dynamic teach-in (ET) | NPN: Teach: U < 2 V NPN: Run: UV – 2 V or open |
Retention time (ET) | 28 ms, non-volatile memory |
Time delay | None |
Connection type | Male connector M8, 4-pin |
Protection class | III |
Circuit protection | UV connections, reverse polarity protected Output Q short-circuit protected Interference pulse suppression |
Enclosure rating | IP67 |
Weight | 20 g |
Housing material | Plastic, ABS |
Optics material | Plastic, PMMA |
Indication | LED indicator green: power on LED indicator, yellow: Status switching output Q |
- 1) Limit values: DC 12 V (–10 %) … DC 24 V (+20 %). Operation in short-circuit protected network max. 8 A.
- 2) May not exceed or fall below Uv tolerances.
- 3) Without load.
- 4) With light/dark ratio 1:1.