IMF12-04BPSNC0S Inductive Proximity Sensors – SICK Sensor

$ 85.79

SKU: SICK 1076673

SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.

Part Number: 1076673
Inductive proximity Sensor Model: IMF12-04BPSNC0S
OEM Spec Ref 

Features

Housing Cylindrical thread design
Housing Standard
Thread size M12 x 1
Diameter Ø 12 mm
Sensing range Sn 4 mm
Safe sensing range Sa 3.24 mm
Installation type Flush
Switching frequency 2,000 Hz
Connection type Male connector M12, 4-pin 1)
Switching output PNP
Output function NO
Electrical wiring DC 3-wire
Enclosure rating IP68 2)

IP69K 3)

Special features Resistant to cleaning agents, Visual adjustment indicator, IO-Link, Temperature resistance
Special applications Hygienic and washdown zones, Difficult application conditions
  • 1) With gold plated contact pins.
  • 2) According to EN 60529.
  • 3) According to ISO 20653:2013-03.

Mechanics/electronics

Supply voltage 10 V DC … 30 V DC
Ripple ≤ 10 %
Voltage drop ≤ 2 V 1)
Current consumption 10 mA 2)
Hysteresis 3 % … 20 %
Reproducibility ≤ 2 % 3) 4)
Temperature drift (of Sr) ± 10 %
EMC According to EN 60947-5-2
Continuous current Ia ≤ 200 mA
Short-circuit protection
Reverse polarity protection
Power-up pulse protection
Shock and vibration resistance 100 g / 2 ms / 500 cycles; 150 g / 1 Mio cycles; 10 Hz … 55 Hz / 1 mm; 55 Hz … 500 Hz / 60 g
Ambient operating temperature –40 °C … +100 °C
Housing material Stainless steel V4A, DIN 1.4404 / AISI 316L
Sensing face material Plastic, LCP
Housing length 65 mm
Thread length 48 mm
Tightening torque, max. Typ. 32 Nm
Items supplied Mounting nut, V4A stainless steel (2x)
Protection class III
UL File No. E181493
  • 1) At Ia max.
  • 2) Without load.
  • 3) Ub and Ta constant.
  • 4) Of Sr.

Safety-related parameters

MTTFD 1,971 years
DCavg 0 %