SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.

Part Number: 6021128
Inductive proximity Sensor Model: IM30-10B-N-ZW0
OEM Spec Ref 

Features

Housing Cylindrical thread design
Thread size M30 x 1.5
Diameter Ø 30 mm
Sensing range Sn 10 mm
Safe sensing range Sa 8.1 mm
Installation type Flush
Switching frequency 450 Hz
Connection type Cable, 2-wire, 2 m
Switching output NAMUR
Output function NC
Enclosure rating IP67 1)
Special applications Explosive areas
  • 1) According to EN 60529.

Mechanics/electronics

Supply voltage 7.5 V DC … 25 V DC 1)
Current consumption 30 mA 1)
Hysteresis 1 % … 15 %
Temperature drift (of Sr) ± 10 %
EMC According to EN 60947-5-6
Current consumption, sensor is activated ≤ 1 mA
Current consumption, sensor is not activated ≥ 2.2 mA
Cable material PVC
Conductor size 0.5 mm²
Cable diameter Ø 5.4 mm
Cable resistance 50 Ω
Shock and vibration resistance 30 g, 11 ms / 10 … 55 Hz, 1 mm
Ambient operating temperature –20 °C … +70 °C
Housing material Brass, nickel-plated
Sensing face material Plastic, PTB
Housing length 41 mm
Thread length 40 mm
Tightening torque, max. 50 Nm
Weight + 233 g
Items supplied Mounting nut, brass, nickel-plated (2x)
Type approval certificate PTB 03 ATEX 2037
Ex area category 1G, 2G
Input voltage Umax. 15 V 2)
Input power Pi max. 120 mW 2)
Input current Imax. 50 mA 2)
Internal capacitance Ci max. 145 nF 2)
Internal inductance Li max. 140 µH 2)
Nominal voltage 8.2 V DC 3)
Device labeling II 1G Ex ia IIC T6 Ga Ta –20 °C … +70 °C, II 2 G Ex ia IIC T6 Gb Ta: –20 °C … +70 °C
  • 1) When used outside the hazardous area.
  • 2) For connection to a separately certified intrinsically safe circuit only.
  • 3) 1 kΩ.

Safety-related parameters

MTTFD 9,926 years
DCavg 0 %

Additional information