IM18-05BUO-ZU0 Inductive Proximity Sensors – SICK Sensor
$ 118.22
SKU: SICK 7902123
SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.
Part Number: 7902123
Inductive proximity Sensor Model: IM18-05BUO-ZU0
OEM Spec Ref
Features
Housing | Cylindrical thread design |
Housing | Standard |
Thread size | M18 x 1 |
Diameter | Ø 18 mm |
Sensing range Sn | 5 mm |
Safe sensing range Sa | 4.05 mm |
Installation type | Flush |
Switching frequency | 25 Hz 1)
100 Hz 2) |
Connection type | Cable, 2-wire, 2 m |
Output function | NC |
Electrical wiring | AC/DC 2-wire |
Enclosure rating | IP67 3) |
- 1) AC.
- 2) DC.
- 3) According to EN 60529.
Mechanics/electronics
Supply voltage | 20 V AC/DC … 250 V AC/DC |
Voltage drop | ≤ 6.5 V AC, ≤ 6 V DC |
Time delay before availability | ≤ 8 ms |
Hysteresis | 1 % … 15 % |
Reproducibility | ≤ 10 % 1) 2) 3) |
Temperature drift (of Sr) | ± 10 % |
EMC | According to EN 60947-5-2
As per EN 55011, class B |
Continuous current Ia | ≤ 350 mA 4)
≤ 250 mA 5) ≤ 100 mA 6) |
Off-state current | ≤ 2.5 mA (AC 250 V)
≤ 1.3 mA (AC 110 V) ≤ 0.8 mA (DC 24 V) |
Minimum load current | ≥ 5 mA |
Short-time withstand current | 2.2 A 7) |
Cable material | PUR |
Conductor size | 0.5 mm² |
Short-circuit protection | – 8) |
Power-up pulse protection | ✔ |
Shock and vibration resistance | 30 g, 11 ms / 10 … 55 Hz, 1 mm |
Ambient operating temperature | –25 °C … +80 °C |
Housing material | Brass, nickel-plated |
Sensing face material | Plastic, PBT |
Housing length | 80 mm |
Thread length | 58 mm |
Tightening torque, max. | ≤ 35 Nm |
Items supplied | Mounting nut, brass, nickel-plated (2x) |
Protection class | II |
Rated insulation voltage Ui | 250 V AC |
Usage category | AC-140 9)
DC-13 10) |
Contamination rating | 3 |
Rated impulse withstand voltage | 4 kV |
- 1) Ub and Ta constant.
- 2) Of Sr.
- 3) Repeatability (Ta not constant).
- 4) AC (+50 °C).
- 5) AC (+80 °C).
- 6) DC.
- 7) 20 ms / 0.5 Hz.
- 8) Miniature fuse to IEC 60217-2 Sheet 1, ≤ 2 A (quick-blow).
- 9) Control of small electromagnetic loads with holding currents < 200 mA.
- 10) Control of solenoids.