IM12-04N-N-ZW0 Inductive Proximity Sensors – SICK Sensor
$ 65.78
SKU: SICK 6021125
SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.
Part Number: 6021125
Inductive proximity Sensor Model: IM12-04N-N-ZW0
OEM Spec Ref
Features
Housing | Cylindrical thread design |
Thread size | M12 x 1 |
Diameter | Ø 12 mm |
Sensing range Sn | 4 mm |
Safe sensing range Sa | 3.24 mm |
Installation type | Non-flush |
Switching frequency | 1,500 Hz |
Connection type | Cable, 2-wire, 2 m |
Switching output | NAMUR |
Output function | NC |
Enclosure rating | IP67 1) |
Special applications | Explosive areas |
- 1) According to EN 60529.
Mechanics/electronics
Supply voltage | 7.5 V DC … 25 V DC 1) |
Current consumption | 30 mA 1) |
Hysteresis | 1 % … 15 % |
Temperature drift (of Sr) | ± 10 % |
EMC | According to EN 60947-5-6 |
Current consumption, sensor is activated | ≤ 1 mA |
Current consumption, sensor is not activated | ≥ 2.2 mA |
Cable material | PVC |
Conductor size | 0.34 mm² |
Cable diameter | Ø 4.9 mm |
Cable resistance | 50 Ω |
Shock and vibration resistance | 30 g, 11 ms / 10 … 55 Hz, 1 mm |
Ambient operating temperature | –20 °C … +70 °C |
Housing material | Brass, nickel-plated |
Sensing face material | Plastic, PTB |
Housing length | 30 mm |
Thread length | 25 mm |
Tightening torque, max. | 7 Nm |
Weight | + 127 g |
Items supplied | Mounting nut, brass, nickel-plated (2x) |
Type approval certificate | PTB 03 ATEX 2037 |
Ex area category | 1G |
Input voltage Ui max. | 15 V 2) |
Input power Pi max. | 120 mW 2) |
Input current Ii max. | 50 mA 2) |
Internal capacitance Ci max. | 140 nF 2) |
Internal inductance Li max. | 130 µH 2) |
Nominal voltage | 8.2 V DC 3) |
Device labeling | II 1G Ex ia IIC T6 Ga Ta –20 °C … +70 °C |
- 1) When used outside the hazardous area.
- 2) For connection to a separately certified intrinsically safe circuit only.
- 3) 1 kΩ.
Safety-related parameters
MTTFD | 5,130 years |
DCavg | 0 % |