Specifications

Main
Part Number RXM3AB1BD RXM3AB1P7 RXM3AB2BD
Product Series Harmony Electromechanical Relays Harmony Electromechanical Relays Harmony Electromechanical Relays
Serial Number Small Small Small
product type Plug-in relay Plug-in relay Plug-in relay
product short name RXM RXM RXM
contact type 3 C/O 3 C/O 3 C/O
Control circuit voltage 24 V DC 230 V AC 50/60 Hz 24 V DC
LED status None None Have
control type Lock test button Lock test button Lock test button
Utilization factor 20% 20% 20%
Additional information
pin type Flat Flat Flat
Rated insulation voltage [Ui] 250 V conforming to IEC
300 V conforming to CSA
300 V conforming to UL
250 V conforming to IEC
300 V conforming to CSA
300 V conforming to UL
250 V conforming to IEC
300 V conforming to CSA
300 V conforming to UL
Rated impulse withstand voltage [Uimp] 4 kV at 1.2/50 µs 4 kV at 1.2/50 µs 4 kV at 1.2/50 µs
contact material AgNi AgNi AgNi
Rated operating current [Ie] 10 A at 28 V (DC) NO conforming to IEC
10 A at 250 V (AC) NO conforming to IEC
5 A at 28 V (DC) NC conforming to IEC 5
A at 250 V (AC) NC conforming to IEC
10 A at 30 V (DC) conforming to UL
10 A at 277 V (AC) conforming to UL
10 A at 28 V (DC) NO conforming to IEC
10 A at 250 V (AC) NO conforming to IEC
5 A at 28 V (DC) NC conforming to IEC 5
A at 250 V (AC) NC conforming to IEC
10 A at 30 V (DC) conforming to UL
10 A at 277 V (AC) conforming to UL
10 A at 28 V (DC) NO conforming to IEC
10 A at 250 V (AC) NO conforming to IEC
5 A at 28 V (DC) NC conforming to IEC 5
A at 250 V (AC) NC conforming to IEC
10 A at 30 V (DC) conforming to UL
10 A at 277 V (AC) conforming to UL
Continuous output current 6.7A 6.7A 6.7A
Maximum Switching Voltage 250 V according to IEC 250 V according to IEC 250 V according to IEC
resistive rated load 10 A at 250 V AC
10 A at 28 V DC
10 A at 250 V AC
10 A at 28 V DC
10 A at 250 V AC
10 A at 28 V DC
Maximum switching capacity 2500VA/280W 2500VA/280W 2500VA/280W
Minimum switching capacity 170 mW at 10 mA, 17 V 170 mW at 10 mA, 17 V 170 mW at 10 mA, 17 V
work rating <=1200 times/hour under load
<=18000 times/hour no load
<=1200 times/hour under load
<=18000 times/hour no load
<=1200 times/hour under load
<=18000 times/hour no load
Mechanical life 10000000 times 10000000 times 10000000 times
Electrical life 100000 times for resistive (load) load 100000 times for resistive (load) load 100000 times for resistive (load) load
average coil consumption 0.9W N/A 0.9W
Pressure drop threshold >= 0.1 Uc >= 0.15 Uc >= 0.1 Uc
operate time 20ms 20ms 20ms
release time 20ms 20ms 20ms
average coil resistance 650 Ω at 20 °C +/- 10 % 15000 Ω at 20 °C +/- 15 % 650 Ω at 20 °C +/- 10 %
Rated operating voltage limit 19.2…26.4V DC 184…253V AC 19.2…26.4V DC
Safe and reliable data B10d = 100000 B10d = 100000 B10d = 100000
Type of protection RT I RT I RT I
test level Grade A Grade A Grade A
operating position Any position Any position Any position
CAD overall height 82.8 mm 82.8 mm 82.8 mm
CAD overall depth 80.35mm 80.35mm 80.35mm
Product Weight 0.037 kg 0.037 kg 0.037 kg
Equipment introduction Product (not parts) Product (not parts) Product (not parts)
environment
Insulation properties 1300 V AC between contacts and micro-break insulation
2000 V AC between coil and contacts
2000 V AC between poles
1300 V AC between contacts and micro-break insulation
2000 V AC between coil and contacts
2000 V AC between poles
1300 V AC between contacts and micro-break insulation
2000 V AC between coil and contacts
2000 V AC between poles
certified product CSA
CE
UL
Lloyd’s
GOST
Lloyd’s
CE
GOST
CSA
UL
UL
CE
CSA
GOST
Lloyd’s
Standards compliant EN/IEC 61810-1
CSA C22.2 No 14
UL 508
EN/IEC 61810-1
CSA C22.2 No 14
UL 508
EN/IEC 61810-1
CSA C22.2 No 14
UL 508
storage environment temperature -40…85°C -40…85°C -40…85°C
ambient temperature -40…55 °C -40…55 °C -40…55 °C
Anti-vibration 3 gn, amplitude = +/- 1 mm (f = 10…150 Hz) for 5 cycles, operating
5 gn, amplitude = +/- 1 mm (f = 10…150 Hz) for 5 cycles, non-operating
3 gn, amplitude = +/- 1 mm (f = 10…150 Hz) for 5 cycles, operating
5 gn, amplitude = +/- 1 mm (f = 10…150 Hz) for 5 cycles, non-operating
3 gn, amplitude = +/- 1 mm (f = 10…150 Hz) for 5 cycles, operating
5 gn, amplitude = +/- 1 mm (f = 10…150 Hz) for 5 cycles, non-operating
IP protection class IP40 conforming to EN/IEC 60529 IP40 conforming to EN/IEC 60529 IP40 conforming to EN/IEC 60529
impact resistance 10 gn for operating period
30 gn for non-operating
10 gn for operating period
30 gn for non-operating
10 gn for operating period
30 gn for non-operating
pollution level 2 2 2
packaging unit
Unit Type of Package 1 PCE PCE PCE
Number of Units in Package 1 1 1 1
Package 1 Height 2cm 2.29cm 3.1cm
Package 1 Width 2.5cm 3.05cm 10.3cm
Package 1 Length 5cm 5.08cm 12.5cm
Package 1 Weight 37g 40g 37g
Unit Type of Package 2 BB1 BB1 BB1
Number of Units in Package 2 10 10 10
Package 2 Height 3cm 3.1cm 3.1cm
Package 2 Width 10cm 10.3 cm 10.3 cm
Package 2 Length 12.5cm 12.6cm 12.5cm
Package 2 Weight 398g 388g 406g
Unit Type of Package 3 S02 S02 S02
Number of Units in Package 3 220 240 240
Package 3 Height 15cm 15cm 15cm
Package 3 Width 30cm 30cm 30cm
Package 3 Length 40cm 40cm 40cm
Package 3 Weight 9.005kg 9.801kg 10.235kg
contract warranty
Warranty 18 months 18 months 18 months

 

Main
Part Number RXM3AB2E7 RXM3AB2P7
Product Series Harmony Electromechanical Relays Harmony Electromechanical Relays
Serial Number Small Small
product type Plug-in relay Plug-in relay
product short name RXM RXM
contact type 3 C/O 3 C/O
Control circuit voltage 48 V AC 50/60 Hz 230 V AC 50/60 Hz
LED status Have Have
control type Lock test button Lock test button
Utilization factor 20% 20%
Additional information
pin type Flat Flat
Rated insulation voltage [Ui] 250 V conforming to IEC
300 V conforming to CSA
300 V conforming to UL
250 V conforming to IEC
300 V conforming to CSA
300 V conforming to UL
Rated impulse withstand voltage [Uimp] 4 kV at 1.2/50 µs 4 kV at 1.2/50 µs
contact material AgNi AgNi
Rated operating current [Ie] 10 A at 28 V (DC) NO conforming to IEC
10 A at 250 V (AC) NO conforming to IEC
5 A at 28 V (DC) NC conforming to IEC 5
A at 250 V (AC) NC conforming to IEC
10 A at 30 V (DC) conforming to UL
10 A at 277 V (AC) conforming to UL
10 A at 28 V (DC) NO conforming to IEC
10 A at 250 V (AC) NO conforming to IEC
5 A at 28 V (DC) NC conforming to IEC 5
A at 250 V (AC) NC conforming to IEC
10 A at 30 V (DC) conforming to UL
10 A at 277 V (AC) conforming to UL
Continuous output current 6.7A 6.7A
Maximum Switching Voltage 250 V according to IEC 250 V according to IEC
resistive rated load 10 A at 250 V AC
10 A at 28 V DC
10 A at 250 V AC
10 A at 28 V DC
Maximum switching capacity 2500VA/280W 2500VA/280W
Minimum switching capacity 170 mW at 10 mA, 17 V 170 mW at 10 mA, 17 V
work rating <=1200 times/hour under load
<=18000 times/hour no load
<=1200 times/hour under load
<=18000 times/hour no load
Mechanical life 10000000 times 10000000 times
Electrical life 100000 times for resistive (load) load 100000 times for resistive (load) load
average coil consumption in VA 1.2 at 60 Hz 1.2 at 60 Hz
Average consumption in VA 1.2 VA at 60 Hz 1.2 VA at 60 Hz
Pressure drop threshold >= 0.15 Uc >= 0.15 Uc
operate time 20ms 20ms
release time 20ms 20ms
average coil resistance 710 Ω at 20 °C +/- 15 % 15000 Ω at 20 °C +/- 15 %
Rated operating voltage limit 38.4…52.8V AC 184…253V AC
Safe and reliable data B10d = 100000 B10d = 100000
Type of protection RT I RT I
test level Grade A Grade A
operating position Any position Any position
CAD overall height 79 mm 82.8mm
CAD overall depth 78.45 mm 80.35mm
Product Weight 0.037 kg 0.037 kg
Equipment introduction Product (not parts) Product (not parts)
environment
Insulation properties 1300 V AC between contacts and micro-break insulation
2000 V AC between coil and contacts
2000 V AC between poles
1300 V AC between contacts and micro-break insulation
2000 V AC between coil and contacts
2000 V AC between poles
certified product CSA
GOST
UL
Lloyd’s
CE
GOST
Lloyd’s
CSA
CE
UL
Standards compliant EN/IEC 61810-1
UL 508
CSA C22.2 No 14
CSA C22.2 No 14
EN/IEC 61810-1
UL 508
storage environment temperature -40…85°C -40…85°C
ambient temperature -40…55 °C -40…55 °C
Anti-vibration 3 gn, amplitude = +/- 1 mm (f = 10…150 Hz) for 5 cycles, operating
5 gn, amplitude = +/- 1 mm (f = 10…150 Hz) for 5 cycles, non-operating
3 gn, amplitude = +/- 1 mm (f = 10…150 Hz) for 5 cycles, operating
5 gn, amplitude = +/- 1 mm (f = 10…150 Hz) for 5 cycles, non-operating
IP protection class IP40 conforming to EN/IEC 60529 IP40 conforming to EN/IEC 60529
impact resistance 10 gn for operating period
30 gn for non-operating
10 gn for operating period
30 gn for non-operating
pollution level 2 2
packaging unit
Unit Type of Package 1 PCE PCE
Number of Units in Package 1 1 1
Package 1 Height 4.1 cm 3.2cm
Package 1 Width 2.1cm 10.3cm
Package 1 Length 2.8cm 12.5cm
Package 1 Weight 38g 38g
Unit Type of Package 2 CAR BB1
Number of Units in Package 2 10 10
Package 2 Height 3cm 3.2cm
Package 2 Width 10.5cm 10.3cm
Package 2 Length 12.1 cm 12.5cm
Package 2 Weight 385g 395g
Unit Type of Package 3 S01 S02
Number of Units in Package 3 120 240
Package 3 Height 15cm 15cm
Package 3 Width 15cm 30cm
Package 3 Length 40cm 40cm
Package 3 Weight 4.845kg 9.92kg
contract warranty
Warranty 18 months 18 months

 

Weight N/A