			$ 8.28 – $ 14.03Price range: $ 8.28 through $ 14.03
| Main | ||||
| Part Number | RXM2AB1BD | RXM2AB1P7 | RXM2AB2BD | RXM2AB2FD | 
| Product Series | Harmony Electromechanical Relays | Harmony Electromechanical Relays | Harmony Electromechanical Relays | Harmony Electromechanical Relays | 
| Serial Number | Small | Small | Small | Small | 
| product type | Plug-in relay | Plug-in relay | Plug-in relay | Plug-in relay | 
| product short name | RXM | RXM | RXM | RXM | 
| contact type | 2 OC | 2 OC | 2 OC | 2 OC | 
| Control circuit voltage | 24 V DC | 230 V AC 50/60 Hz | 24 V DC | 110V DC | 
| LED status | None | None | Have | Have | 
| control type | Lock test button | Lock test button | Lock test button | Lock test button | 
| Utilization factor | 20% | 20% | 20% | 20% | 
| Additional information | ||||
| pin type | Flat | Flat | Flat | Flat | 
| Rated insulation voltage [Ui] | 250 V conforming to IEC 300 V conforming to CSA 300 V conforming to UL | 250 V conforming to IEC 300 V conforming to CSA 300 V conforming to UL | 250 V conforming to IEC 300 V conforming to CSA 300 V conforming to UL | 250 V conforming to IEC 300 V conforming to CSA 300 V conforming to UL | 
| Rated impulse withstand voltage [Uimp] | 4 kV at 1.2/50 µs | 4 kV at 1.2/50 µs | 4 kV at 1.2/50 µs | 4 kV at 1.2/50 µs | 
| contact material | AgNi | AgNi | AgNi | AgNi | 
| Rated operating current [Ie] | 12 A at 28 V (DC) NO conforming to IEC 12 A at 250 V (AC) NO conforming to IEC 6 A at 28 V (DC) NC conforming to IEC 6 A at 250 V (AC) NC conforming to IEC 12 A at 28 V (DC) conforming to UL 12 A at 277 V (AC) conforming to UL | 12 A at 28 V (DC) NO conforming to IEC 12 A at 250 V (AC) NO conforming to IEC 6 A at 28 V (DC) NC conforming to IEC 6 A at 250 V (AC) NC conforming to IEC 12 A at 28 V (DC) conforming to UL 12 A at 277 V (AC) conforming to UL | 12 A at 28 V (DC) NO conforming to IEC 12 A at 250 V (AC) NO conforming to IEC 6 A at 28 V (DC) NC conforming to IEC 6 A at 250 V (AC) NC conforming to IEC 12 A at 28 V (DC) conforming to UL 12 A at 277 V (AC) conforming to UL | 12 A at 28 V (DC) NO conforming to IEC 12 A at 250 V (AC) NO conforming to IEC 6 A at 28 V (DC) NC conforming to IEC 6 A at 250 V (AC) NC conforming to IEC 12 A at 28 V (DC) conforming to UL 12 A at 277 V (AC) conforming to UL | 
| Continuous output current | 10A | 10A | 10A | 10A | 
| Maximum Switching Voltage | 250 V according to IEC | 250 V according to IEC | 250 V according to IEC | 250 V according to IEC | 
| resistive rated load | 12 A at 250 V AC 12 A at 28 V DC | 12 A at 250 V AC 12 A at 28 V DC | 12 A at 250 V AC 12 A at 28 V DC | 12 A at 250 V AC 12 A at 28 V DC | 
| Maximum switching capacity | 3000VA/336W | 3000VA/336W | 3000VA/336W | 3000VA/336W | 
| Minimum switching capacity | 170 mW at 10 mA, 17 V | 170 mW at 10 mA, 17 V | 170 mW at 10 mA, 17 V | 170 mW at 10 mA, 17 V | 
| work rating | <=1200 times/hour under load <=18000 times/hour no load | <=1200 times/hour under load <=18000 times/hour no load | <=1200 times/hour under load <=18000 times/hour no load | <=1200 times/hour under load <=18000 times/hour no load | 
| Mechanical life | 10000000 times | 10000000 times | 10000000 times | 10000000 times | 
| Electrical life | 100000 times for resistive (load) load | 100000 times for resistive (load) load | 100000 times for resistive (load) load | 100000 times for resistive (load) load | 
| average coil consumption | 0.9W | N/A | 0.9W | 0.9W | 
| Pressure drop threshold | >= 0.1 Uc | >= 0.15 Uc | >= 0.1 Uc | >= 0.1 Uc | 
| operate time | 20ms | 20ms | 20ms | 20ms | 
| release time | 20ms | 20ms | 20ms | 20ms | 
| average coil resistance | 650 Ω at 20 °C +/- 10 % | 15000 Ω at 20 °C +/- 15 % | 650 Ω at 20 °C +/- 10 % | 13440 Ω at 20 °C +/- 10 % | 
| Rated operating voltage limit | 19.2…26.4V DC | 184…253V AC | 19.2…26.4V DC | 88…121V DC | 
| Safe and reliable data | B10d = 100000 | B10d = 100000 | B10d = 100000 | B10d = 100000 | 
| Type of protection | RT I | RT I | RT I | RT I | 
| test level | Grade A | Grade A | Grade A | Grade A | 
| operating position | Any position | Any position | Any position | Any position | 
| Product Weight | 0.037 kg | 0.037 kg | 0.037 kg | 0.037 kg | 
| Equipment introduction | Product (not parts) | Product (not parts) | Product (not parts) | Product (not parts) | 
| environment | ||||
| Insulation properties | 1300 V AC Insulation between contacts and microbreak 2000 V AC Insulation between coil and contacts and basic insulation 2000 V AC Insulation between poles and basic insulation | 1300 V AC Insulation between contacts and microbreak 2000 V AC Insulation between coil and contacts and basic insulation 2000 V AC Insulation between poles and basic insulation | 1300 V AC Insulation between contacts and microbreak 2000 V AC Insulation between coil and contacts and basic insulation 2000 V AC Insulation between poles and basic insulation | 1300 V AC Insulation between contacts and microbreak 2000 V AC Insulation between coil and contacts and basic insulation 2000 V AC Insulation between poles and basic insulation | 
| certified product | GOST CSA UL Lloyd’s CE | CSA UL GOST Lloyd’s CE | GOST UL Lloyd’s CSA CE | GOST Lloyd’s UL CSA CE | 
| Standards compliant | CSA C22.2 No 14 UL 508 EN/IEC 61810-1 | EN/IEC 61810-1 UL 508 CSA C22.2 No 14 | CSA C22.2 No 14 EN/IEC 61810-1 UL 508 | CSA C22.2 No 14 EN/IEC 61810-1 UL 508 | 
| storage environment temperature | -40…85°C | -40…85°C | -40…85°C | -40…85°C | 
| ambient temperature | -40…55 °C | -40…55 °C | -40…55 °C | -40…55 °C | 
| Anti-vibration | 3 gn, amplitude = +/- 1 mm (f = 10…150 Hz) for 5 cycles, operating 5 gn, amplitude = +/- 1 mm (f = 10…150 Hz) for 5 cycles, non-operating | 3 gn, amplitude = +/- 1 mm (f = 10…150 Hz) for 5 cycles, operating 5 gn, amplitude = +/- 1 mm (f = 10…150 Hz) for 5 cycles, non-operating | 3 gn, amplitude = +/- 1 mm (f = 10…150 Hz) for 5 cycles, operating 5 gn, amplitude = +/- 1 mm (f = 10…150 Hz) for 5 cycles, non-operating | 3 gn, amplitude = +/- 1 mm (f = 10…150 Hz) for 5 cycles, operating 5 gn, amplitude = +/- 1 mm (f = 10…150 Hz) for 5 cycles, non-operating | 
| IP protection class | IP40 conforming to EN/IEC 60529 | IP40 conforming to EN/IEC 60529 | IP40 conforming to EN/IEC 60529 | IP40 conforming to EN/IEC 60529 | 
| impact resistance | 10 gn for operating period 30 gn for non-operating | 10 gn for operating period 30 gn for non-operating | 10 gn for operating period 30 gn for non-operating | 10 gn for operating period 30 gn for non-operating | 
| pollution level | 3 | 3 | 3 | 3 | 
| packaging unit | ||||
| Unit Type of Package 1 | PCE | PCE | PCE | PCE | 
| Number of Units in Package 1 | 1 | 1 | 1 | 1 | 
| Package 1 Height | 4.8cm | 2.1cm | 2.0cm | 2.2cm | 
| Package 1 Width | 2.1cm | 2.2cm | 2.8cm | 2.8cm | 
| Package 1 Length | 2.7cm | 4.7cm | 4.8cm | 4.8cm | 
| Package 1 Weight | 36 grams | 35g | 37.0g | 36 grams | 
| Unit Type of Package 2 | BB1 | BB1 | BB1 | BB1 | 
| Number of Units in Package 2 | 10 | 10 | 10 | 10 | 
| Package 2 Height | 3cm | 3cm | 3.0cm | 3.4cm | 
| Package 2 Width | 10.2 cm | 10.2 cm | 10.0cm | 10.4 cm | 
| Package 2 Length | 12.5cm | 12.5cm | 12.5cm | 12.7cm | 
| Package 2 Weight | 393g | 382g | 396.0g | 395g | 
| Unit Type of Package 3 | S02 | S02 | S02 | S02 | 
| Number of Units in Package 3 | 240 | 240 | 240 | 240 | 
| Package 3 Height | 15cm | 15cm | 15.0cm | 15cm | 
| Package 3 Width | 30cm | 30cm | 30.0cm | 30cm | 
| Package 3 Length | 40cm | 40cm | 40.0cm | 40cm | 
| Package 3 Weight | 9.928 kg | 9.695 kg | 9.994kg | 9.99kg | 
| contract warranty | ||||
| Warranty | 18 months | 18 months | 18 months | 18 months | 
| Main | ||||
| Part Number | RXM2AB2P7 | RXM2CB1P7 | RXM2LB1P7 | RXM2LB2BD | 
| Product Series | Harmony Electromechanical Relays | Harmony Electromechanical Relays | Harmony Electromechanical Relays | Harmony Electromechanical Relays | 
| Serial Number | Small | Small | Small | Small | 
| product type | Plug-in relay | Plug-in relay | Plug-in relay | Plug-in relay | 
| product short name | RXM | RXM | RXM | RXM | 
| contact type | 2 OC | 2 OC | 2 OC | 2 OC | 
| Control circuit voltage | 230 V AC 50/60 Hz | 230 V AC 50/60 Hz | 230 V AC 50/60 Hz | 24 V DC | 
| LED status | Have | None | None | Have | 
| control type | Lock test button | N/A | No button | No button | 
| Utilization factor | 20% | 20% | 20% | 20% | 
| Additional information | ||||
| pin type | Flat | N/A | ||
| Rated insulation voltage [Ui] | 250 V conforming to IEC 300 V conforming to CSA 300 V conforming to UL | 250 V conforming to IEC 300 V conforming to UL | 250 V according to IEC | 250 V according to IEC | 
| Rated impulse withstand voltage [Uimp] | 4 kV at 1.2/50 µs | 3.6 kV at 1.2/50 µs conforming to IEC 61810-7 | 4 kV at 1.2/50 µs conforming to IEC 61810-7 | 4 kV at 1.2/50 µs conforming to IEC 61810-7 | 
| contact material | AgNi | Silver Alloy (Silver/Nickel) | Silver Alloy (Silver/Nickel) | Silver Alloy (Silver/Nickel) | 
| Rated operating current [Ie] | 12 A at 28 V (DC) NO conforming to IEC 12 A at 250 V (AC) NO conforming to IEC 6 A at 28 V (DC) NC conforming to IEC 6 A at 250 V (AC) NC conforming to IEC 12 A at 28 V (DC) conforming to UL 12 A at 277 V (AC) conforming to UL | 10 A (AC-1/DC-1) conforming to UL 10 A (AC-1/DC-1) NO conforming to IEC 5 A (AC-1/DC-1) NC conforming to IEC | 5 A (AC-1/DC-1) NO conforming to IEC 2.5 A (AC-1/DC-1) NC conforming to IEC 1 A at 28 V (DC-13) NO | 5 A (AC-1/DC-1) NO conforming to IEC 2.5 A (AC-1/DC-1) NC conforming to IEC 1 A at 28 V (DC-13) NO | 
| Continuous output current | 10A | N/A | ||
| Maximum Switching Voltage | 250 V according to IEC | 250 V AC 125 V DC | 250 V AC 28 V DC | 250 V AC 28 V DC | 
| resistive rated load | 12 A at 250 V AC 12 A at 28 V DC | N/A | ||
| Maximum switching capacity | 3000VA/336W | 2500VA AC 300W DC | 1250VA AC 140W DC | 1250VA AC 140W DC | 
| Minimum switching capacity | 170 mW at 10 mA, 17 V | 170 mW | 170 mW | 170 mW | 
| work rating | <=1200 times/hour under load <=18000 times/hour no load | <=1200 times/hour under load <=18000 times/hour no load | <=1200 times/hour under load <=18000 times/hour no load | <=1200 times/hour under load <=18000 times/hour no load | 
| Mechanical life | 10000000 times | 10000000 times | 10000000 times | 10000000 times | 
| Electrical life | 100000 times for resistive (load) load | 100000 times applicable resistive (load) quantity | 100000 cycles for resistive (load) capacity 50000 cycles, 1 A at 28 V, DC-13 NO | 100000 cycles for resistive (load) capacity 50000 cycles, 1 A at 28 V, DC-13 NO | 
| average coil consumption in VA | 1.2 at 60 Hz | N/A | ||
| Average consumption in VA | 1.2 VA at 60 Hz | 1.55 AC | 1.2 AC | |
| Pressure drop threshold | >= 0.15 Uc | >= 0.15 Uc AC | >= 0.15 Uc AC | >= 0.1 Uc DC | 
| operate time | 20ms | N/A | ||
| release time | 20ms | |||
| average coil resistance | 15000 Ω at 20 °C +/- 15 % | |||
| Rated operating voltage limit | 184…253V AC | 184…253V AC | 184…253V AC | 19.2…26.4V DC | 
| Safe and reliable data | B10d = 100000 | B10d = 100000 | B10d = 100000 | B10d = 100000 | 
| Type of protection | RT I | RT I | RT I | RT I | 
| test level | Grade A | Grade A | Grade A | Grade A | 
| operating position | Any position | Any position | Any position | Any position | 
| CAD overall height | 82.8 mm | 27 mm | 27 mm | 27 mm | 
| CAD overall depth | 80.35 mm | 55 mm | 46 mm | 46 mm | 
| Product Weight | 0.037 kg | 0.035 kg | N/A | 0.032kg | 
| Equipment introduction | Product (not parts) | N/A | ||
| environment | ||||
| Insulation properties | 1300 V AC Insulation between contacts and microbreak 2000 V AC Insulation between coil and contacts and basic insulation 2000 V AC Insulation between poles and basic insulation | 1800 V AC between coil and contacts 1550 V AC between poles 1000 V AC between contacts | 2000 V AC insulation between coil and contacts and basic insulation 2000 V AC insulation between poles and basic insulation 1000 V AC insulation between contacts and microbreak | 2000 V AC insulation between coil and contacts and basic insulation 2000 V AC insulation between poles and basic insulation 1000 V AC insulation between contacts and microbreak | 
| certified product | CSA GOST UL CE Lloyd’s | UL GOST | N/A | |
| Standards compliant | EN/IEC 61810-1 UL 508 CSA C22.2 No 14 | UL 508 EN/IEC 61810-1 | CE EN/IEC 61810-1 (Phase 2) | EN/IEC 61810-1 (Phase 2) CE | 
| storage environment temperature | -40…85°C | -40…70°C | -40…85°C | -40…85°C | 
| ambient temperature | -40…55 °C | -40…55 °C | -40…55 °C | -40…55 °C | 
| Anti-vibration | 3 gn, amplitude = +/- 1 mm (f = 10…150 Hz) for 5 cycles, operating 5 gn, amplitude = +/- 1 mm (f = 10…150 Hz) for 5 cycles, non-operating | 3 gn, amplitude = +/- 1 mm (f = 10…55 Hz) without protective clip conforming to EN/IEC 60068-2-6 5 gn, amplitude = +/- 1 mm (f = 10…55 Hz) with Protective clip conforming to EN/IEC 60068-2-6 | 3 gn, amplitude = +/- 1 mm (f = 10…50 Hz) operating according to EN/IEC 60068-2-6 6 gn, amplitude = +/- 1 mm (f = 10…50 Hz) non-operating according to EN /IEC 60068-2-6 | 3 gn, amplitude = +/- 1 mm (f = 10…50 Hz) operating according to EN/IEC 60068-2-6 6 gn, amplitude = +/- 1 mm (f = 10…50 Hz) non-operating according to EN /IEC 60068-2-6 | 
| IP protection class | IP40 conforming to EN/IEC 60529 | IP40 conforming to EN/IEC 60529 | IP40 conforming to EN/IEC 60529 | IP40 conforming to EN/IEC 60529 | 
| impact resistance | 10 gn for operating period 30 gn for non-operating | 10 gn (duration = 11 ms) for opening according to EN/IEC 60068-2-27 10 gn (duration = 11 ms) for closing according to EN/IEC 60068-2-27 | 30 gn for non-operation according to EN/IEC 60068-2-27 10 gn for operation according to EN/IEC 60068-2-27 | 30 gn for non-operation according to EN/IEC 60068-2-27 10 gn for operation according to EN/IEC 60068-2-27 | 
| pollution level | 3 | N/A | 3 | 3 | 
| packaging unit | ||||
| Unit Type of Package 1 | PCE | PCE | PCE | PCE | 
| Number of Units in Package 1 | 1 | 1 | 1 | 1 | 
| Package 1 Height | 2.6cm | 3.2cm | 2.1cm | 2.0cm | 
| Package 1 Width | 2.0cm | 1.03cm | 2.7cm | 2.5cm | 
| Package 1 Length | 5.0cm | 1.26cm | 4.6cm | 4.5cm | 
| Package 1 Weight | 35.0g | 4.0g | 31.0g | 33.0g | 
| Unit Type of Package 2 | BB1 | BB1 | BB1 | BB1 | 
| Number of Units in Package 2 | 10 | 10 | 10 | 10 | 
| Package 2 Height | 3.0cm | 2.9cm | 3.0cm | 3.0cm | 
| Package 2 Width | 10.2cm | 10.0cm | 11.5cm | 10.5cm | 
| Package 2 Length | 12.5cm | 11.6cm | 10.0cm | 12.5cm | 
| Package 2 Weight | 386.0g | 350.0g | 390.0g | 363.0g | 
| Unit Type of Package 3 | S02 | CAR | S02 | S02 | 
| Number of Units in Package 3 | 240 | 270 | 270 | 270 | 
| Package 3 Height | 15.0cm | 15.0cm | 15.0cm | 15.0cm | 
| Package 3 Width | 30.0cm | 29.9cm | 30.0cm | 30.0cm | 
| Package 3 Length | 40.0cm | 39.8cm | 40.0cm | 40.0cm | 
| Package 3 Weight | 9.734kg | 9.0kg | 10.985kg | 10.065kg | 
| contract warranty | ||||
| Warranty | 18 months | 18 months | 18 months | 18 months | 
| Main | ||
| Part Number | RXM2LB2JD | RXM2LB2P7 | 
| Product Series | Harmony Electromechanical Relays | Harmony Electromechanical Relays | 
| Serial Number | Small | Small | 
| product type | Plug-in relay | Plug-in relay | 
| product short name | RXM | RXM | 
| Interference free coil | None | None | 
| Utilization factor | 20% | 20% | 
| Quantity sold separately | 10 | 10 | 
| Additional information | ||
| contact type | 2 OC | 2 OC | 
| contact action | Standard | Standard | 
| Control circuit voltage | 12 V DC | 230 V AC 50/60 Hz | 
| Rated load current in case [Ithe] | 5 A at -40…55 °C | 5 A at -40…55 °C | 
| LED status | Have | Have | 
| control type | No button | No button | 
| Rated insulation voltage [Ui] | 250 V according to IEC | 250 V according to IEC | 
| Rated impulse withstand voltage [Uimp] | 4 kV at 1.2/50 µs conforming to IEC 61810-7 | 4 kV at 1.2/50 µs conforming to IEC 61810-7 | 
| contact material | Silver Alloy (Silver/Nickel) | Silver Alloy (Silver/Nickel) | 
| Rated operating current [Ie] | 5 A (AC-1/DC-1) NO conforming to IEC 2.5 A (AC-1/DC-1) NC conforming to IEC 1 A at 28 V (DC-13) NO | 5 A (AC-1/DC-1) NO conforming to IEC 2.5 A (AC-1/DC-1) NC conforming to IEC 1 A at 28 V (DC-13) NO | 
| Minimum switching current | 10 mA | 10 mA | 
| Maximum Switching Voltage | 250 V AC 28 V DC | 250 V AC 28 V DC | 
| Minimum switching voltage | 17V | 17V | 
| load current | 5 A at 250 V AC 5 A at 28 V DC | 5 A at 250 V AC 5 A at 28 V DC | 
| Maximum switching capacity | 1250VA AC 140W DC | 1250VA AC 140W DC | 
| Minimum switching capacity | 170 mW | 170 mW | 
| work rating | <=1200 times/hour under load <=18000 times/hour no load | <=1200 times/hour under load <=18000 times/hour no load | 
| Mechanical life | 10000000 times | 10000000 times | 
| Electrical life | 100000 cycles for resistive (load) capacity 50000 cycles, 1 A at 28 V, DC-13 NO | 100000 cycles for resistive (load) capacity 50000 cycles, 1 A at 28 V, DC-13 NO | 
| Average consumption, unit is W | 0.9W, DC | N/A | 
| Pressure drop threshold | >= 0.1 Uc DC | >= 0.15 Uc AC | 
| action time | 20 ms coil discharge and closing of off-delay contact 20 ms coil energization and closing of on-delay contact | 20 ms coil discharge and closing of off-delay contact 20 ms coil energization and closing of on-delay contact | 
| average resistance | 160 Ω at 23 °C +/- 10 % | 16500 Ω at 23 °C +/- 15 % | 
| Rated operating voltage limit | 9.6…13.2V DC | 184…253V AC | 
| Type of protection | RT I | RT I | 
| test level | Grade A | Grade A | 
| operating position | Any position | Any position | 
| CAD overall width | 21 mm | 21 mm | 
| CAD overall height | 27 mm | 27 mm | 
| CAD overall depth | 46 mm | 46 mm | 
| Product Weight | 0.033 kg | 0.031 kg | 
| Insulation properties | 2000 V AC insulation between coil and contacts and basic insulation 2000 V AC insulation between poles and basic insulation 1000 V AC insulation between contacts and microbreak | 2000 V AC insulation between coil and contacts and basic insulation 2000 V AC insulation between poles and basic insulation 1000 V AC insulation between contacts and microbreak | 
| Safe and reliable data | B10d = 100000 | B10d = 100000 | 
| environment | ||
| Standards compliant | CE EN/IEC 61810-1 (Phase 2) | CE EN/IEC 61810-1 (Phase 2) | 
| storage environment temperature | -40…85°C | -40…85°C | 
| ambient temperature | -40…55 °C | -40…55 °C | 
| Anti-vibration | 3 gn, amplitude = +/- 1 mm (f = 10…50 Hz) operating according to EN/IEC 60068-2-6 6 gn, amplitude = +/- 1 mm (f = 10…50 Hz) non-operating according to EN /IEC 60068-2-6 | 3 gn, amplitude = +/- 1 mm (f = 10…50 Hz) operating according to EN/IEC 60068-2-6 6 gn, amplitude = +/- 1 mm (f = 10…50 Hz) non-operating according to EN /IEC 60068-2-6 | 
| IP protection class | IP40 conforming to EN/IEC 60529 | IP40 conforming to EN/IEC 60529 | 
| pollution level | 3 | 3 | 
| impact resistance | 30 gn for non-operation according to EN/IEC 60068-2-27 10 gn for operation according to EN/IEC 60068-2-27 | 30 gn for non-operation according to EN/IEC 60068-2-27 10 gn for operation according to EN/IEC 60068-2-27 | 
| packaging unit | ||
| Unit Type of Package 1 | PCE | PCE | 
| Number of Units in Package 1 | 1 | 1 | 
| Package 1 Height | 2.095cm | 2.0cm | 
| Package 1 Width | 2.748 cm | 3.0cm | 
| Package 1 Length | 4.56cm | 4.5cm | 
| Package 1 Weight | 39.0g | 32.0g | 
| Unit Type of Package 2 | BB1 | BB1 | 
| Number of Units in Package 2 | 10 | 10 | 
| Package 2 Height | 2.9cm | 3.0cm | 
| Package 2 Width | 10.8 cm | 10.5cm | 
| Package 2 Length | 13.3 cm | 12.0cm | 
| Package 2 Weight | 350.0g | 348.0g | 
| Unit Type of Package 3 | S02 | |
| Number of Units in Package 3 | 270 | |
| Package 3 Height | 15.0cm | |
| Package 3 Width | 30.0cm | |
| Package 3 Length | 40.0cm | |
| Package 3 Weight | 10.521kg | |
| contract warranty | ||