$ 7.92 – $ 13.42
Main | ||||
Part Number | RXM2AB1BD | RXM2AB1P7 | RXM2AB2BD | RXM2AB2FD |
Product Series | Harmony Electromechanical Relays | Harmony Electromechanical Relays | Harmony Electromechanical Relays | Harmony Electromechanical Relays |
Serial Number | Small | Small | Small | Small |
product type | Plug-in relay | Plug-in relay | Plug-in relay | Plug-in relay |
product short name | RXM | RXM | RXM | RXM |
contact type | 2 OC | 2 OC | 2 OC | 2 OC |
Control circuit voltage | 24 V DC | 230 V AC 50/60 Hz | 24 V DC | 110V DC |
LED status | None | None | Have | Have |
control type | Lock test button | Lock test button | Lock test button | Lock test button |
Utilization factor | 20% | 20% | 20% | 20% |
Additional information | ||||
pin type | Flat | Flat | Flat | Flat |
Rated insulation voltage [Ui] | 250 V conforming to IEC 300 V conforming to CSA 300 V conforming to UL |
250 V conforming to IEC 300 V conforming to CSA 300 V conforming to UL |
250 V conforming to IEC 300 V conforming to CSA 300 V conforming to UL |
250 V conforming to IEC 300 V conforming to CSA 300 V conforming to UL |
Rated impulse withstand voltage [Uimp] | 4 kV at 1.2/50 µs | 4 kV at 1.2/50 µs | 4 kV at 1.2/50 µs | 4 kV at 1.2/50 µs |
contact material | AgNi | AgNi | AgNi | AgNi |
Rated operating current [Ie] | 12 A at 28 V (DC) NO conforming to IEC 12 A at 250 V (AC) NO conforming to IEC 6 A at 28 V (DC) NC conforming to IEC 6 A at 250 V (AC) NC conforming to IEC 12 A at 28 V (DC) conforming to UL 12 A at 277 V (AC) conforming to UL |
12 A at 28 V (DC) NO conforming to IEC 12 A at 250 V (AC) NO conforming to IEC 6 A at 28 V (DC) NC conforming to IEC 6 A at 250 V (AC) NC conforming to IEC 12 A at 28 V (DC) conforming to UL 12 A at 277 V (AC) conforming to UL |
12 A at 28 V (DC) NO conforming to IEC 12 A at 250 V (AC) NO conforming to IEC 6 A at 28 V (DC) NC conforming to IEC 6 A at 250 V (AC) NC conforming to IEC 12 A at 28 V (DC) conforming to UL 12 A at 277 V (AC) conforming to UL |
12 A at 28 V (DC) NO conforming to IEC 12 A at 250 V (AC) NO conforming to IEC 6 A at 28 V (DC) NC conforming to IEC 6 A at 250 V (AC) NC conforming to IEC 12 A at 28 V (DC) conforming to UL 12 A at 277 V (AC) conforming to UL |
Continuous output current | 10A | 10A | 10A | 10A |
Maximum Switching Voltage | 250 V according to IEC | 250 V according to IEC | 250 V according to IEC | 250 V according to IEC |
resistive rated load | 12 A at 250 V AC 12 A at 28 V DC |
12 A at 250 V AC 12 A at 28 V DC |
12 A at 250 V AC 12 A at 28 V DC |
12 A at 250 V AC 12 A at 28 V DC |
Maximum switching capacity | 3000VA/336W | 3000VA/336W | 3000VA/336W | 3000VA/336W |
Minimum switching capacity | 170 mW at 10 mA, 17 V | 170 mW at 10 mA, 17 V | 170 mW at 10 mA, 17 V | 170 mW at 10 mA, 17 V |
work rating | <=1200 times/hour under load <=18000 times/hour no load |
<=1200 times/hour under load <=18000 times/hour no load |
<=1200 times/hour under load <=18000 times/hour no load |
<=1200 times/hour under load <=18000 times/hour no load |
Mechanical life | 10000000 times | 10000000 times | 10000000 times | 10000000 times |
Electrical life | 100000 times for resistive (load) load | 100000 times for resistive (load) load | 100000 times for resistive (load) load | 100000 times for resistive (load) load |
average coil consumption | 0.9W | N/A | 0.9W | 0.9W |
Pressure drop threshold | >= 0.1 Uc | >= 0.15 Uc | >= 0.1 Uc | >= 0.1 Uc |
operate time | 20ms | 20ms | 20ms | 20ms |
release time | 20ms | 20ms | 20ms | 20ms |
average coil resistance | 650 Ω at 20 °C +/- 10 % | 15000 Ω at 20 °C +/- 15 % | 650 Ω at 20 °C +/- 10 % | 13440 Ω at 20 °C +/- 10 % |
Rated operating voltage limit | 19.2…26.4V DC | 184…253V AC | 19.2…26.4V DC | 88…121V DC |
Safe and reliable data | B10d = 100000 | B10d = 100000 | B10d = 100000 | B10d = 100000 |
Type of protection | RT I | RT I | RT I | RT I |
test level | Grade A | Grade A | Grade A | Grade A |
operating position | Any position | Any position | Any position | Any position |
Product Weight | 0.037 kg | 0.037 kg | 0.037 kg | 0.037 kg |
Equipment introduction | Product (not parts) | Product (not parts) | Product (not parts) | Product (not parts) |
environment | ||||
Insulation properties | 1300 V AC Insulation between contacts and microbreak 2000 V AC Insulation between coil and contacts and basic insulation 2000 V AC Insulation between poles and basic insulation |
1300 V AC Insulation between contacts and microbreak 2000 V AC Insulation between coil and contacts and basic insulation 2000 V AC Insulation between poles and basic insulation |
1300 V AC Insulation between contacts and microbreak 2000 V AC Insulation between coil and contacts and basic insulation 2000 V AC Insulation between poles and basic insulation |
1300 V AC Insulation between contacts and microbreak 2000 V AC Insulation between coil and contacts and basic insulation 2000 V AC Insulation between poles and basic insulation |
certified product | GOST CSA UL Lloyd’s CE |
CSA UL GOST Lloyd’s CE |
GOST UL Lloyd’s CSA CE |
GOST Lloyd’s UL CSA CE |
Standards compliant | CSA C22.2 No 14 UL 508 EN/IEC 61810-1 |
EN/IEC 61810-1 UL 508 CSA C22.2 No 14 |
CSA C22.2 No 14 EN/IEC 61810-1 UL 508 |
CSA C22.2 No 14 EN/IEC 61810-1 UL 508 |
storage environment temperature | -40…85°C | -40…85°C | -40…85°C | -40…85°C |
ambient temperature | -40…55 °C | -40…55 °C | -40…55 °C | -40…55 °C |
Anti-vibration | 3 gn, amplitude = +/- 1 mm (f = 10…150 Hz) for 5 cycles, operating 5 gn, amplitude = +/- 1 mm (f = 10…150 Hz) for 5 cycles, non-operating |
3 gn, amplitude = +/- 1 mm (f = 10…150 Hz) for 5 cycles, operating 5 gn, amplitude = +/- 1 mm (f = 10…150 Hz) for 5 cycles, non-operating |
3 gn, amplitude = +/- 1 mm (f = 10…150 Hz) for 5 cycles, operating 5 gn, amplitude = +/- 1 mm (f = 10…150 Hz) for 5 cycles, non-operating |
3 gn, amplitude = +/- 1 mm (f = 10…150 Hz) for 5 cycles, operating 5 gn, amplitude = +/- 1 mm (f = 10…150 Hz) for 5 cycles, non-operating |
IP protection class | IP40 conforming to EN/IEC 60529 | IP40 conforming to EN/IEC 60529 | IP40 conforming to EN/IEC 60529 | IP40 conforming to EN/IEC 60529 |
impact resistance | 10 gn for operating period 30 gn for non-operating |
10 gn for operating period 30 gn for non-operating |
10 gn for operating period 30 gn for non-operating |
10 gn for operating period 30 gn for non-operating |
pollution level | 3 | 3 | 3 | 3 |
packaging unit | ||||
Unit Type of Package 1 | PCE | PCE | PCE | PCE |
Number of Units in Package 1 | 1 | 1 | 1 | 1 |
Package 1 Height | 4.8cm | 2.1cm | 2.0cm | 2.2cm |
Package 1 Width | 2.1cm | 2.2cm | 2.8cm | 2.8cm |
Package 1 Length | 2.7cm | 4.7cm | 4.8cm | 4.8cm |
Package 1 Weight | 36 grams | 35g | 37.0g | 36 grams |
Unit Type of Package 2 | BB1 | BB1 | BB1 | BB1 |
Number of Units in Package 2 | 10 | 10 | 10 | 10 |
Package 2 Height | 3cm | 3cm | 3.0cm | 3.4cm |
Package 2 Width | 10.2 cm | 10.2 cm | 10.0cm | 10.4 cm |
Package 2 Length | 12.5cm | 12.5cm | 12.5cm | 12.7cm |
Package 2 Weight | 393g | 382g | 396.0g | 395g |
Unit Type of Package 3 | S02 | S02 | S02 | S02 |
Number of Units in Package 3 | 240 | 240 | 240 | 240 |
Package 3 Height | 15cm | 15cm | 15.0cm | 15cm |
Package 3 Width | 30cm | 30cm | 30.0cm | 30cm |
Package 3 Length | 40cm | 40cm | 40.0cm | 40cm |
Package 3 Weight | 9.928 kg | 9.695 kg | 9.994kg | 9.99kg |
contract warranty | ||||
Warranty | 18 months | 18 months | 18 months | 18 months |
Main | ||||
Part Number | RXM2AB2P7 | RXM2CB1P7 | RXM2LB1P7 | RXM2LB2BD |
Product Series | Harmony Electromechanical Relays | Harmony Electromechanical Relays | Harmony Electromechanical Relays | Harmony Electromechanical Relays |
Serial Number | Small | Small | Small | Small |
product type | Plug-in relay | Plug-in relay | Plug-in relay | Plug-in relay |
product short name | RXM | RXM | RXM | RXM |
contact type | 2 OC | 2 OC | 2 OC | 2 OC |
Control circuit voltage | 230 V AC 50/60 Hz | 230 V AC 50/60 Hz | 230 V AC 50/60 Hz | 24 V DC |
LED status | Have | None | None | Have |
control type | Lock test button | N/A | No button | No button |
Utilization factor | 20% | 20% | 20% | 20% |
Additional information | ||||
pin type | Flat | N/A | ||
Rated insulation voltage [Ui] | 250 V conforming to IEC 300 V conforming to CSA 300 V conforming to UL |
250 V conforming to IEC 300 V conforming to UL |
250 V according to IEC | 250 V according to IEC |
Rated impulse withstand voltage [Uimp] | 4 kV at 1.2/50 µs | 3.6 kV at 1.2/50 µs conforming to IEC 61810-7 | 4 kV at 1.2/50 µs conforming to IEC 61810-7 | 4 kV at 1.2/50 µs conforming to IEC 61810-7 |
contact material | AgNi | Silver Alloy (Silver/Nickel) | Silver Alloy (Silver/Nickel) | Silver Alloy (Silver/Nickel) |
Rated operating current [Ie] | 12 A at 28 V (DC) NO conforming to IEC 12 A at 250 V (AC) NO conforming to IEC 6 A at 28 V (DC) NC conforming to IEC 6 A at 250 V (AC) NC conforming to IEC 12 A at 28 V (DC) conforming to UL 12 A at 277 V (AC) conforming to UL |
10 A (AC-1/DC-1) conforming to UL 10 A (AC-1/DC-1) NO conforming to IEC 5 A (AC-1/DC-1) NC conforming to IEC |
5 A (AC-1/DC-1) NO conforming to IEC 2.5 A (AC-1/DC-1) NC conforming to IEC 1 A at 28 V (DC-13) NO |
5 A (AC-1/DC-1) NO conforming to IEC 2.5 A (AC-1/DC-1) NC conforming to IEC 1 A at 28 V (DC-13) NO |
Continuous output current | 10A | N/A | ||
Maximum Switching Voltage | 250 V according to IEC | 250 V AC 125 V DC |
250 V AC 28 V DC |
250 V AC 28 V DC |
resistive rated load | 12 A at 250 V AC 12 A at 28 V DC |
N/A | ||
Maximum switching capacity | 3000VA/336W | 2500VA AC 300W DC |
1250VA AC 140W DC |
1250VA AC 140W DC |
Minimum switching capacity | 170 mW at 10 mA, 17 V | 170 mW | 170 mW | 170 mW |
work rating | <=1200 times/hour under load <=18000 times/hour no load |
<=1200 times/hour under load <=18000 times/hour no load |
<=1200 times/hour under load <=18000 times/hour no load |
<=1200 times/hour under load <=18000 times/hour no load |
Mechanical life | 10000000 times | 10000000 times | 10000000 times | 10000000 times |
Electrical life | 100000 times for resistive (load) load | 100000 times applicable resistive (load) quantity | 100000 cycles for resistive (load) capacity 50000 cycles, 1 A at 28 V, DC-13 NO |
100000 cycles for resistive (load) capacity 50000 cycles, 1 A at 28 V, DC-13 NO |
average coil consumption in VA | 1.2 at 60 Hz | N/A | ||
Average consumption in VA | 1.2 VA at 60 Hz | 1.55 AC | 1.2 AC | |
Pressure drop threshold | >= 0.15 Uc | >= 0.15 Uc AC | >= 0.15 Uc AC | >= 0.1 Uc DC |
operate time | 20ms | N/A | ||
release time | 20ms | |||
average coil resistance | 15000 Ω at 20 °C +/- 15 % | |||
Rated operating voltage limit | 184…253V AC | 184…253V AC | 184…253V AC | 19.2…26.4V DC |
Safe and reliable data | B10d = 100000 | B10d = 100000 | B10d = 100000 | B10d = 100000 |
Type of protection | RT I | RT I | RT I | RT I |
test level | Grade A | Grade A | Grade A | Grade A |
operating position | Any position | Any position | Any position | Any position |
CAD overall height | 82.8 mm | 27 mm | 27 mm | 27 mm |
CAD overall depth | 80.35 mm | 55 mm | 46 mm | 46 mm |
Product Weight | 0.037 kg | 0.035 kg | N/A | 0.032kg |
Equipment introduction | Product (not parts) | N/A | ||
environment | ||||
Insulation properties | 1300 V AC Insulation between contacts and microbreak 2000 V AC Insulation between coil and contacts and basic insulation 2000 V AC Insulation between poles and basic insulation |
1800 V AC between coil and contacts 1550 V AC between poles 1000 V AC between contacts |
2000 V AC insulation between coil and contacts and basic insulation 2000 V AC insulation between poles and basic insulation 1000 V AC insulation between contacts and microbreak |
2000 V AC insulation between coil and contacts and basic insulation 2000 V AC insulation between poles and basic insulation 1000 V AC insulation between contacts and microbreak |
certified product | CSA GOST UL CE Lloyd’s |
UL GOST |
N/A | |
Standards compliant | EN/IEC 61810-1 UL 508 CSA C22.2 No 14 |
UL 508 EN/IEC 61810-1 |
CE EN/IEC 61810-1 (Phase 2) |
EN/IEC 61810-1 (Phase 2) CE |
storage environment temperature | -40…85°C | -40…70°C | -40…85°C | -40…85°C |
ambient temperature | -40…55 °C | -40…55 °C | -40…55 °C | -40…55 °C |
Anti-vibration | 3 gn, amplitude = +/- 1 mm (f = 10…150 Hz) for 5 cycles, operating 5 gn, amplitude = +/- 1 mm (f = 10…150 Hz) for 5 cycles, non-operating |
3 gn, amplitude = +/- 1 mm (f = 10…55 Hz) without protective clip conforming to EN/IEC 60068-2-6 5 gn, amplitude = +/- 1 mm (f = 10…55 Hz) with Protective clip conforming to EN/IEC 60068-2-6 |
3 gn, amplitude = +/- 1 mm (f = 10…50 Hz) operating according to EN/IEC 60068-2-6 6 gn, amplitude = +/- 1 mm (f = 10…50 Hz) non-operating according to EN /IEC 60068-2-6 |
3 gn, amplitude = +/- 1 mm (f = 10…50 Hz) operating according to EN/IEC 60068-2-6 6 gn, amplitude = +/- 1 mm (f = 10…50 Hz) non-operating according to EN /IEC 60068-2-6 |
IP protection class | IP40 conforming to EN/IEC 60529 | IP40 conforming to EN/IEC 60529 | IP40 conforming to EN/IEC 60529 | IP40 conforming to EN/IEC 60529 |
impact resistance | 10 gn for operating period 30 gn for non-operating |
10 gn (duration = 11 ms) for opening according to EN/IEC 60068-2-27 10 gn (duration = 11 ms) for closing according to EN/IEC 60068-2-27 |
30 gn for non-operation according to EN/IEC 60068-2-27 10 gn for operation according to EN/IEC 60068-2-27 |
30 gn for non-operation according to EN/IEC 60068-2-27 10 gn for operation according to EN/IEC 60068-2-27 |
pollution level | 3 | N/A | 3 | 3 |
packaging unit | ||||
Unit Type of Package 1 | PCE | PCE | PCE | PCE |
Number of Units in Package 1 | 1 | 1 | 1 | 1 |
Package 1 Height | 2.6cm | 3.2cm | 2.1cm | 2.0cm |
Package 1 Width | 2.0cm | 1.03cm | 2.7cm | 2.5cm |
Package 1 Length | 5.0cm | 1.26cm | 4.6cm | 4.5cm |
Package 1 Weight | 35.0g | 4.0g | 31.0g | 33.0g |
Unit Type of Package 2 | BB1 | BB1 | BB1 | BB1 |
Number of Units in Package 2 | 10 | 10 | 10 | 10 |
Package 2 Height | 3.0cm | 2.9cm | 3.0cm | 3.0cm |
Package 2 Width | 10.2cm | 10.0cm | 11.5cm | 10.5cm |
Package 2 Length | 12.5cm | 11.6cm | 10.0cm | 12.5cm |
Package 2 Weight | 386.0g | 350.0g | 390.0g | 363.0g |
Unit Type of Package 3 | S02 | CAR | S02 | S02 |
Number of Units in Package 3 | 240 | 270 | 270 | 270 |
Package 3 Height | 15.0cm | 15.0cm | 15.0cm | 15.0cm |
Package 3 Width | 30.0cm | 29.9cm | 30.0cm | 30.0cm |
Package 3 Length | 40.0cm | 39.8cm | 40.0cm | 40.0cm |
Package 3 Weight | 9.734kg | 9.0kg | 10.985kg | 10.065kg |
contract warranty | ||||
Warranty | 18 months | 18 months | 18 months | 18 months |
Main | ||
Part Number | RXM2LB2JD | RXM2LB2P7 |
Product Series | Harmony Electromechanical Relays | Harmony Electromechanical Relays |
Serial Number | Small | Small |
product type | Plug-in relay | Plug-in relay |
product short name | RXM | RXM |
Interference free coil | None | None |
Utilization factor | 20% | 20% |
Quantity sold separately | 10 | 10 |
Additional information | ||
contact type | 2 OC | 2 OC |
contact action | Standard | Standard |
Control circuit voltage | 12 V DC | 230 V AC 50/60 Hz |
Rated load current in case [Ithe] | 5 A at -40…55 °C | 5 A at -40…55 °C |
LED status | Have | Have |
control type | No button | No button |
Rated insulation voltage [Ui] | 250 V according to IEC | 250 V according to IEC |
Rated impulse withstand voltage [Uimp] | 4 kV at 1.2/50 µs conforming to IEC 61810-7 | 4 kV at 1.2/50 µs conforming to IEC 61810-7 |
contact material | Silver Alloy (Silver/Nickel) | Silver Alloy (Silver/Nickel) |
Rated operating current [Ie] | 5 A (AC-1/DC-1) NO conforming to IEC 2.5 A (AC-1/DC-1) NC conforming to IEC 1 A at 28 V (DC-13) NO |
5 A (AC-1/DC-1) NO conforming to IEC 2.5 A (AC-1/DC-1) NC conforming to IEC 1 A at 28 V (DC-13) NO |
Minimum switching current | 10 mA | 10 mA |
Maximum Switching Voltage | 250 V AC 28 V DC |
250 V AC 28 V DC |
Minimum switching voltage | 17V | 17V |
load current | 5 A at 250 V AC 5 A at 28 V DC |
5 A at 250 V AC 5 A at 28 V DC |
Maximum switching capacity | 1250VA AC 140W DC |
1250VA AC 140W DC |
Minimum switching capacity | 170 mW | 170 mW |
work rating | <=1200 times/hour under load <=18000 times/hour no load |
<=1200 times/hour under load <=18000 times/hour no load |
Mechanical life | 10000000 times | 10000000 times |
Electrical life | 100000 cycles for resistive (load) capacity 50000 cycles, 1 A at 28 V, DC-13 NO |
100000 cycles for resistive (load) capacity 50000 cycles, 1 A at 28 V, DC-13 NO |
Average consumption, unit is W | 0.9W, DC | N/A |
Pressure drop threshold | >= 0.1 Uc DC | >= 0.15 Uc AC |
action time | 20 ms coil discharge and closing of off-delay contact 20 ms coil energization and closing of on-delay contact |
20 ms coil discharge and closing of off-delay contact 20 ms coil energization and closing of on-delay contact |
average resistance | 160 Ω at 23 °C +/- 10 % | 16500 Ω at 23 °C +/- 15 % |
Rated operating voltage limit | 9.6…13.2V DC | 184…253V AC |
Type of protection | RT I | RT I |
test level | Grade A | Grade A |
operating position | Any position | Any position |
CAD overall width | 21 mm | 21 mm |
CAD overall height | 27 mm | 27 mm |
CAD overall depth | 46 mm | 46 mm |
Product Weight | 0.033 kg | 0.031 kg |
Insulation properties | 2000 V AC insulation between coil and contacts and basic insulation 2000 V AC insulation between poles and basic insulation 1000 V AC insulation between contacts and microbreak |
2000 V AC insulation between coil and contacts and basic insulation 2000 V AC insulation between poles and basic insulation 1000 V AC insulation between contacts and microbreak |
Safe and reliable data | B10d = 100000 | B10d = 100000 |
environment | ||
Standards compliant | CE EN/IEC 61810-1 (Phase 2) |
CE EN/IEC 61810-1 (Phase 2) |
storage environment temperature | -40…85°C | -40…85°C |
ambient temperature | -40…55 °C | -40…55 °C |
Anti-vibration | 3 gn, amplitude = +/- 1 mm (f = 10…50 Hz) operating according to EN/IEC 60068-2-6 6 gn, amplitude = +/- 1 mm (f = 10…50 Hz) non-operating according to EN /IEC 60068-2-6 |
3 gn, amplitude = +/- 1 mm (f = 10…50 Hz) operating according to EN/IEC 60068-2-6 6 gn, amplitude = +/- 1 mm (f = 10…50 Hz) non-operating according to EN /IEC 60068-2-6 |
IP protection class | IP40 conforming to EN/IEC 60529 | IP40 conforming to EN/IEC 60529 |
pollution level | 3 | 3 |
impact resistance | 30 gn for non-operation according to EN/IEC 60068-2-27 10 gn for operation according to EN/IEC 60068-2-27 |
30 gn for non-operation according to EN/IEC 60068-2-27 10 gn for operation according to EN/IEC 60068-2-27 |
packaging unit | ||
Unit Type of Package 1 | PCE | PCE |
Number of Units in Package 1 | 1 | 1 |
Package 1 Height | 2.095cm | 2.0cm |
Package 1 Width | 2.748 cm | 3.0cm |
Package 1 Length | 4.56cm | 4.5cm |
Package 1 Weight | 39.0g | 32.0g |
Unit Type of Package 2 | BB1 | BB1 |
Number of Units in Package 2 | 10 | 10 |
Package 2 Height | 2.9cm | 3.0cm |
Package 2 Width | 10.8 cm | 10.5cm |
Package 2 Length | 13.3 cm | 12.0cm |
Package 2 Weight | 350.0g | 348.0g |
Unit Type of Package 3 | S02 | |
Number of Units in Package 3 | 270 | |
Package 3 Height | 15.0cm | |
Package 3 Width | 30.0cm | |
Package 3 Length | 40.0cm | |
Package 3 Weight | 10.521kg | |
contract warranty | ||
Warranty | 18 months | 18 months |
Weight | N/A |
---|---|
Dimensions | N/A |
INOSAKI Limited
RM B 5/F Gaylord Comm,
Bldg 114-118 Lockhart Rd.
Hong Kong
INOSAKI Sdn. Bhd.
2-1-9, Ground Floor, One Square, Tingkat Mahsuri 1,
11900 Bayan Lepas, Penan
INOSAKI Pte. Ltd.
101 Upper Cross Street,
No. 06-17, People’s Park Centre,