Operating modes |
Supply voltage | 0.05 s to 300 h models | |
---|---|---|---|
11-pin models | 8-pin models | ||
Flicker OFF start |
100 to 240 VAC/ 100 to 125 VDC |
H3CR-F 100-240AC/100-125DC | H3CR-F8 100-240AC/100-125DC |
24 to 48 VAC/ 12 to 48 VDC |
H3CR-F 24-48AC/12-48DC | H3CR-F8 24-48AC/12-48DC | |
Flicker ON start |
100 to 240 VAC/ 100 to 125 VDC |
H3CR-FN 100-240AC/100-125DC | H3CR-F8N 100-240AC/100-125DC |
24 to 48 VAC/ 12 to 48 VDC |
H3CR-FN 24-48AC/12-48DC | H3CR-F8N 24-48AC/12-48DC |
Item | H3CR-F | H3CR-F8 | H3CR-FN | H3CR-F8N |
---|---|---|---|---|
Operating mode | Flicker OFF start | Flicker ON start | ||
Pin type | 11-pin | 8-pin | 11-pin | 8-pin |
Operating/Reset method | Time-limit operation/Time-limit reset or self-reset | |||
Output type | Relay output (DPDT) | |||
Mounting method | DIN track mounting, surface mounting, and flush mounting | |||
Approved standards | UL508, CSA C22.2 No.14, NK, Lloyds, CCC: GB/T 14048.5 * Conforms to EN61812-1 and IEC60664-1 (VDE0110) 4kV/2. |
Note: For details, refer to your OMRON website.
* CCC certification requirements
Recommended fuse | 0216005 (250VAC, 5A), manufactured by Littelfuse |
---|---|
Rated operating voltage Ue Rated operating current Ie |
AC-15: Ue: 250 VAC, Ie: 3 A AC-13: Ue: 250 VAC, Ie: 5 A DC-13: Ue: 30 VDC, Ie: 1.5 A |
Rated insulation voltage | 250 V |
Rated impulse withstand voltage (altitude: 2,000 m max.) |
4 kV (at 240 VAC) |
Conditional short-circuit current | 1000 A |
Time unit | s (sec) | ×10 s (10 sec) | min (min) | ×10 min (10 min) | h (hrs) | ×10 h (10 hrs) | |
---|---|---|---|---|---|---|---|
Fullscale setting |
1.2 | 0.05 to 1.2 | 1.2 to 12 | 0.12 to 1.2 | 1.2 to 12 | 0.12 to 1.2 | 1.2 to 12 |
3 | 0.3 to 3 | 3 to 30 | 0.3 to 3 | 3 to 30 | 0.3 to 3 | 3 to 30 | |
12 | 1.2 to 12 | 12 to 120 | 1.2 to 12 | 12 to 120 | 1.2 to 12 | 12 to 120 | |
30 | 3 to 30 | 30 to 300 | 3 to 30 | 30 to 300 | 3 to 30 | 30 to 300 |
Note: The times that can be set are given. When the time setting knob is turned below “0” until the point where the time
setting knob stops, the output will operate instantaneously at all time range settings.
For details, refer to your OMRON website.
Rated supply voltage *1 *2 *3 | • 100 to 240 VAC 50/60 Hz/100 to 125 VDC • 24 to 48 VAC 50/60 Hz/12 to 48 VDC |
---|---|
Operating voltage range | 85% to 110% of rated supply voltage; 90% to 110% with 12-VDC models |
Power reset | Minimum power-opening time: 0.1 s |
Power consumption | 100 to 240 VAC: approx. 10 VA (2.1 W) at 240 VAC 24 VAC/VDC: approx. 2 VA (1.7 W) at 24 VAC, approx. 1 W at 24 VDC |
Control outputs | Contact output: 5 A at 250 VAC/30 VDC, resistive load (cosφ = 1) The minimum applicable load is 10mA at 5VDC (P reference value). Contact materials: Ag-alloy |
*1. A power supply with a ripple of 20% max. (single-phase power supply with full-wave rectification) can be used with
each DC Model.
*2. Do not use an inverter output as the power supply. Refer to your OMRON website for details.
*3. Refer to your OMRON website when using the Timer together with a 2-wire AC proximity sensor.
Accuracy of operating time |
±0.2% FS max. (±0.2% FS ±10 ms max. in ranges of 1.2 and 3 s) |
---|---|
Setting error | ±5% FS ±50 ms max. |
Reset time | 0.1 s max. |
Reset voltage | 10% max. of rated voltage |
Influence of voltage | ±0.2% FS max. (±0.2% FS ±10 ms max. in ranges of 1.2 and 3 s) |
Influence of temperature |
±1% FS max. (±1% FS ±10 ms max. in ranges of 1.2 and 3s) |
Insulation resistance | 100 MΩ min. (at 500 VDC) |
Dielectric strength | 2,000 VAC, 50/60 Hz for 1 min (between current-carrying metal parts and exposed non- current-carrying metal parts) 2,000 VAC, 50/60 Hz for 1 min (between control output terminals and operating circuit) 2,000 VAC, 50/60 Hz for 1 min (between contacts of different polarities) 1,000 VAC, 50/60 Hz for 1 min (between contacts not located next to each other) |
Impulse withstand voltage |
5kV (between power terminals), however, 1kV for 24 to 48VAC, 12 to 48 VDC 5kV (between current-carrying terminal and exposed non-current-carrying metal parts), however 1.5 kV for 24 to 48 VAC, 12 to 48 VDC |
Noise immunity | ±1.5 kV (between power terminals), square-wave noise by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise) |
Static immunity | Malfunction: 8 kV Destruction: 15 kV |
Vibration resistance | Destruction: 10 to 55 Hz with 0.75-mm single amplitude for 2 hrs each in three directions Malfunction: 10 to 55 Hz with 0.5-mm single amplitude for 10 min each in three directions |
Shock resistance | Destruction: 980 m/s2 three times each in six directions Malfunction: 98 m/s2 three times each in six directions |
Ambient temperature | Operating: -10°C to 55°C (with no icing) Storage: -25°C to 65°C (with no icing) |
Ambient humidity | Operating: 35% to 85% |
Life expectancy | Mechanical: 20 million operations min. (under no load at 1,800 operations/h) Electrical: 100,000 operations min. (5 A at 250 VAC, resistive load at 1,800 operations/h) * |
EMC | (EMI) EN61812-1 Emission Enclosure: EN55011 Group 1 class A Emission AC Mains: EN55011 Group 1 class A (EMS) EN61812-1 Immunity ESD: IEC61000-4-2 Immunity RF-interference: IEC61000-4-3 Immunity Burst: IEC61000-4-4 Immunity Surge: IEC61000-4-5 Immunity Conducted Disturbance: IEC61000-4-6 Immunity Voltage Dip/Interruption: IEC61000-4-11 |
Case color | Light Gray (Munsell 5Y7/1) |
Degree of protection | IP40 (panel surface) |
Weight | Approx. 100 g |
Weight | N/A |
---|---|
Model |
INOSAKI Limited
RM B 5/F Gaylord Comm,
Bldg 114-118 Lockhart Rd.
Hong Kong
INOSAKI Sdn. Bhd.
2-1-9, Ground Floor, One Square, Tingkat Mahsuri 1,
11900 Bayan Lepas, Penan
INOSAKI Pte. Ltd.
101 Upper Cross Street,
No. 06-17, People’s Park Centre,
Singapore (058357)