List of models

Control the output Supply voltage 11PIN type 8PIN type
Output by Dot:

DPDT

(Time-limited output)

AC110V (50/60Hz) H3BA-N AC110V
AC220V (50/60Hz) H3BA-N AC220V
DC24V H3BA-N DC24V
Output by Dot:

Limited time SPDT with

SPDT can be switched

(Limited time ↔, instantaneous)

AC110V (50/60Hz) H3BA-N8H AC110V
AC220V (50/60Hz) H3BA-N8H AC220V
DC24V H3BA-N8H DC24V

 

General

project H3BA-N H3BA-N8H
Action mode A: ON Delay
B: Flashing OFF Start
B2: Flashing ON Start
C: Signal ON/OFF Delay
D: Signal OFF Delay
E: Interval
G: Signal ON/OFF Delay
J: Monostable output
A: ON Delay
H: ON Delay with Instantaneous Output Contact
Pin type 11pin 8pin
Input method No voltage input
Output mode DPDT (Limited Time) SPDT (time-limited) vs. switchable SPDT (time-limited<—>instant)
Installation: Aluminum rail mounting, surface mounting, and flush mounting
Applicable Standards UL508, CSA C22.2 No.14, LR and CCC : GB/T 14048.5*
according to EN 61812-1 (Pollution 2 / Overvoltage Category III)
EMC (EMI) EN 61812-1
Radiological hazard intensity: EN 55011 class A AC power supply immunity: EN 55011 class A

(EMS) EN 61812-1
Immunity to electrostatic discharge: EN 61000-4-2: 6kV contact discharge

8kV Air Discharge
Radiated Radio Frequency: EN 61000-4-3: 10V/m (80MHz~1GHz AM modulation) Electric Field Strength Immunity: 3V/m (1.4GHz~2GHz AM Modulation)

1V/m (2GHz~2.7GHz AM modulation) 10V/m (900MHz pulse modulation) Conducted Noise Immunity: EN 61000-4-6: 10V (0.15MHz~80MHz)

Radio Pulse Immunity: EN 61000-4-4: 2kV power cord

2kV I/O Signal Line
Surge immunity: EN 61000-4-5: 2kV common mode

1kV Different Modes
Voltage sag: EN 61000-4-11
Electrical shut-off immunity: EN 61000-4-11

 

*About CCC acquisition conditions

Proposed fuses 0216005 (250VAC, 5A) manufactured by Littelfuse
Rated operating voltage Ue
Rated operating voltage Ie
AC-15: Ue: 250VAC, Ie: 3A
AC-13: Ue: 250VAC, Ie: 5A
DC-13: Ue: 30VDC, Ie: 0.1A
Rated insulation voltage 250V
Rated impulse voltage
(Height: 2000m or less)
4kV (at AC240V)
Conditional short-circuit current 1,000A

 

 

Time frame

Units of time s (seconds) x 10s

(10 seconds)

min

(min)

x 10min

(ten minutes)

h

(hours)

x 10h

(10 hours)

Full scale setting
1.2 Set the time 0.05~1.2 1.2~12 0.12~1.2 1.2~12 0.12~1.2 1.2~12
3 0.3~3 3~30 0.3~3 3~30 0.3~3 3~30
12 1.2~12 12~120 1.2~12 12~120 1.2~12 12~120
30 3~30 30~300 3~30 30~300 3~30 30~300

 

Rated specifications

project H3BA-N H3BA-N8H
Rated supply voltage

(Please refer to Notes 1 and 2)

AC110V (50/60Hz)、AC220V (50/60Hz)、DC24V
Voltage range of use

(See Note 3)

85%~110% of rated power supply voltage
Power restoration Minimum power on time: 0.1s
No voltage input Impedance at ON: 1 kΩ or less Residual voltage at
ON: 1 V or less Impedance at OFF: 200 kΩ or
more
Power consumption AC110V: Approx. 4.6VA (1.5W) AC220V: Approx. 7.6VA (1.3W)

DC24V: Approx. 0.6W

AC110V: Approx. 3.6VA (1.6W) AC220V: Approx. 7.8VA (1.9W)

DC24V: Approx. 0.9W

Control the output Contact: 5A at 250V AC, resistive load (cosφ = 1)

 

 

Note 1. The DC ripple rate is less than 20%.

Note 2. Using models other than the DC24V H3BA-N type will generate a surge current.

When powering on these models through a contactless output such as a sensor, be aware of the surge current.

Note 3. If the timer is used continuously at high ambient temperatures, the DC standard ripple rate is 90% or higher.

 

Characteristic

project H3BA-N H3BA-N8H
Accuracy of action time ± 0.3% FS or less (±0.3% ±10ms in 1.2s range)
Setting error ±5% FS ±0.05s or less
Return time Minimum power on time: 0.1s or less
Minimum pulse input time: 50ms
Voltage effects ± 0.5% FS or less (±0.5% ±10ms in 1.2s range)
Temperature effects ±2% FS or less (±2% ±10ms in the 1.2s range)
Insulation resistance 100MΩ min. (at 500 VDC)
Withstand voltage AC2,000V, 50/60Hz 1min (between conductive metal and exposed non-conductive metal) AC2,000V, 50/60Hz 1min (between control output terminal and operation circuit) AC1,000V, 50/60Hz 1min (between non-continuous contacts) (AC750V for H3BA-N8H type)
Impulse voltage 1kV (between power terminals) 2kV (between conductive terminals and exposed non-conductive metal parts, 1.5kV for DC24V type)
Noise resistant Type AC:

± 1.5kV (between power terminals) and 600V (between input terminals) ±

Square wave noise generated by noise simulator (pulse width: 100ns/1μs, 1ns rise)
DC type:

± 480V (between power terminals), ± 600V (between input terminals).

Square wave noise generated by the noise simulator (pulse width: 100ns/1μs, 1ns ramp)

Resistant to static electricity Malfunction: 4kV Durability: 8kV
Vibration resistant Durability: 10~55Hz, 0.75mm single amplitude, 3 directions, 1 time each
Malfunction: 10~55Hz, 0.5mm single amplitude, 3 directions, 1 time each
Impact-resistant Durability: 1,000 m/s2 (approx. 100 G), 3 directions, 1 time each
Malfunction: 100 m/s2 (approx. 10 G), 3 directions, 1 time each
Ambient temperature Operation: -10°C~55°C (no icing) Storage: -25°C~65°C (no freezing)
Ambient humidity Operation: 35%~85%
Service life Mechanical: 10,000,000 cycles
or more (1,800 cycles/hour at no load)
Electrical: 100,000 cycles or more

(AC250V 5A Resistive Load,

1800 times/hour)

Mechanical: 10,000,000 cycles
or more (1,800 cycles/hour at no load)
Electrical: 100,000 cycles or more

(AC250V 5A Resistive Load,

360 times/hour)

Housing color Light grey (Munsell 5Y7/1)
Ingress protection IEC: IP40 (panel surface)
weight Approximately 95g

 

 

Note. To set the timer limit to a loop of less than 3 seconds or to use forced reset, use the H3BA-N type D mode (signal OFF delay).

 