$ 42.90
Item | Specifications |
---|---|
Product Number | GX-FL15A-P |
Part Number | GX-FL15A-P |
CE marking directive compliance | EMC Directive, RoHS Directive |
Max. operation distance | 8.0 mm 0.315 in plus or minus 8 % (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. (Note) This is when mounted onto an insulant plate. When mounted onto a steel or stainless steel plate, insert the optional aluminum sheet between the sensor and the plate. |
Stable sensing range | 0 to 6.7 mm 0 to 0.264 in (Note) The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. (Note) This is when mounted onto an insulant plate. When mounted onto a steel or stainless steel plate, insert the optional aluminum sheet between the sensor and the plate. |
Standard sensing object | Iron sheet 30 × 30 × t 1 mm 1.181 × 1.181 × t 0.039 in |
Hysteresis | 20 % or less of operation distance(with standard sensing object) |
Repeatability | Along sensing axis, perpendicular to sensing axis: 0.04 mm 0.002 in or less |
Supply voltage | 12 to 24 V DC +10/-15 % Ripple P-P 10 % or less |
Current consumption | 15 mA or less |
Output | PNP open-collector transistor – Maximum source current: 100 mA – Applied voltage: 30 V DC or less(between output and +V) – Residual voltage: 2 V or less (at 100 mA source current) |
Output:Output operation | Normally open |
Output:Utilization category | DC-12 or DC-13 |
Max. response frequency | 150 Hz (Note) This is when mounted onto an insulant plate. When mounted onto a metallic plate, max. response frequency will decrease. |
Operation indicator | Orange LED(lights up when the output is ON) |
Protection | IP68 (IEC), IP68g (JEM) (Note) Panasonic Electric Works SUNX’s IP68 test method 1. Immerse at 0 m below 0 ℃ +32 ℉ water surface and leave for 30 min. Then, immerse at 0 m below +70 ℃ +158 ℉ water surface and leave for 30 min. 2. Regard the heat shock test in 1 as one cycle and perform 20 cycles. 3. Leave in water at a depth of 1 m 3.281 ft in water for 500 hours. 4. After tests 1 to 3, insulation resistance, voltage withstandability, current consumption, and sensing ranges must meet the standard values. (Note) If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil. |
Ambient temperature | -25 to +70 ℃ -13 to +158 ℉ , Storage: – 40 to +85 ℃ – 40 to +185 ※ |
Ambient humidity | 45 to 85 % RH, Storage: 35 to 95 % RH |
Voltage withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
Insulation resistance | 50 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure |
Vibration resistance | 10 to 500 Hz frequency, 3 mm 0.118 in double amplitude (Max. 20 G) in X, Y and Z directions for two hours each |
Shock resistance | 10,000 m/s2 acceleration (1,000 G approx.) in X, Y and Z directions three times each |
Sensing range variation:Temperature characteristics | Over ambient temperature range -25 to +70 ℃ -13 to +158 ℉ : Within plus or minus 8 % of sensing range at +23degrees +73.4degrees Fahrenheit . |
Sensing range variation:Voltage characteristics | Within plus or minus 2 % for +10/-15 % fluctuation of the supply voltage |
Material | Enclosure: PBT Indicator part: Polyester |
Cable | 0.15 mm2 3-core oil, heat and cold resistant cabtyre cable, 1 m 3.281 ft long |
Cable extension | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. |
Net weight | 20 g approx. |
Weight | 0.020 kg |
---|