Skip to content

Contact Us:
sales@inosaki.com

SICK 1080814 GSE6-N1112P04 NPN Through-beam Sensor with Slit Mask

SICK 1080814 GSE6-N1112P04 NPN Through-beam Sensor with Slit Mask

USD 104.52

Through-beam sensor with BEF-SLIT MASK-G6, 0–2 m maximum range, NPN light/dark output, <500 µs response and a 2 m PVC cable connection.

SKU: SICK-1080814 Category:
SICK G6

SICK GSE6-N1112P04 NPN Through-beam Photoelectric Sensor

BrandSICK
Model IdentifierGSE6-N1112P04
Official Part Number1080814

Technical Overview

The SICK GSE6-N1112P04 is a through-beam photoelectric sensor configuration with a 0–2 m maximum sensing range and BEF-SLIT MASK-G6. A 650 nm red PinPoint LED sends light to the separate receiver, whose NPN output provides selectable light or dark switching. The sensing sensitivity has no adjustment facility; the light/dark selector establishes the output behavior. Response is below 500 µs with resistive load, with 1,000 Hz switching at a 1:1 light/dark ratio. The 10–30 V DC configuration uses a 2 m three-wire PVC cable connection, ABS/PC housing, PMMA front screen and IP67 protection. A stainless-steel BEF-W100-A mounting bracket is supplied, and output current is limited to 50 mA above 24 V.

NPN through-beam sensor with BEF-SLIT MASK-G6, 0–2 m maximum range, selectable light/dark switching and 2 m PVC cable connection.

Key Features

  • Through-beam sensing with separate sender and receiver
  • 0–2 m maximum sensing range for this slit-mask configuration
  • With BEF-SLIT MASK-G6; 650 nm red PinPoint LED
  • NPN output; selectable light/dark switching
  • No sensing-sensitivity adjustment facility
  • Response <500 µs with resistive load; 1,000 Hz at 1:1 light/dark ratio
  • 10–30 V DC; 30 mA without load; output ≤100 mA, limited to 50 mA above 24 V
  • 2 m three-wire PVC cable connection; 0.14 mm² conductors
  • ABS/PC housing and PMMA front screen; IP67; M3 mounting holes
  • Stainless-steel 1.4301/304 BEF-W100-A mounting bracket supplied

Detect interruptions between the separate sender and receiver using the slit-mask configuration and selectable NPN switching behavior.

Technical Specification Matrix

ParameterValue
Functional principleThrough-beam photoelectric sensor; separate sender and receiver
Maximum sensing range0–2 m for the selected slit-mask configuration
Special featureWith BEF-SLIT MASK-G6
Polarization filterNo
Light sourceVisible red PinPoint LED; 650 nm
Average LED service life100,000 h at TU = +25 °C
Sensitivity adjustmentNone
Digital outputNPN; ≤100 mA; at supply >24 V, maximum 50 mA
Switching modeLight/dark switching, selectable by light/dark selector
Response time<500 µs signal transit time with resistive load
Switching frequency1,000 Hz at 1:1 light/dark ratio
Power supply10–30 V DC; limit values with short-circuit-protected network, max. 8 A
Ripple±10%; remain within supply tolerances
Current consumption30 mA without load
Protection classIII
Circuit protectionA: supply reverse-polarity protection; B: input/output reverse-polarity protection; D: output overcurrent and short-circuit protection
Connection2 m three-wire PVC cable
Conductor cross-section0.14 mm²
Cable handlingDo not bend below 0 °C
Wire assignmentsCD-049: sender BN=L+, BU=M, BK not connected; receiver BN=L+, BU=M, BK=Q
Housing designRectangular
Housing materialABS/PC plastic
Front screen materialPMMA plastic
IP ratingIP67
Operating temperature−25 to +55 °C; temperature stability following adjustment ±10 °C
Storage temperature−40 to +70 °C
MountingM3 holes
IndicationGreen LED: supply active; yellow LED: received-light status
Items suppliedStainless-steel 1.4301/304 BEF-W100-A mounting bracket
UL filesNRKH.E348498 and NRKH7.E348498

Industrial Applications

1. Counting separated components crossing a guide

A component guide can pass separated opaque parts between the sender and receiver within the selected configuration’s 2 m maximum range. The slit-mask configuration and fixed sensitivity establish the optical arrangement, while external counting logic reads the selected NPN light/dark signal. Setup checks actual component coverage, alignment and spacing against the response below 500 µs and 1,000 Hz rating.

Problem Solved

A beam-interruption reference helps external counting logic register separated components passing a fixed guide location, using opposing optical units and an NPN switching signal.

Component counting Through-beam Slit-mask configuration

2. Triggering a process from a presented leading edge

A process station can place the sender and receiver across an opaque workpiece route so its leading edge interrupts the beam at a fixed reference line. The selected NPN transition feeds the external process controller for its timing sequence. Commissioning checks actual edge coverage, sender/receiver alignment and electrical input delay, while the controller provides any required travel compensation.

Problem Solved

A leading-edge reference gives external process control a defined trigger location for coordinating a downstream operation with workpiece movement, using a selected light/dark transition.

Leading-edge trigger Process timing NPN

3. Monitoring a material-loop threshold in a feed buffer

A material buffer can position the sender and receiver across a chosen loop level so an opaque web interrupts the beam when it reaches that threshold. External feed logic uses the NPN state to coordinate delivery with buffer demand. Setup checks web coverage, flutter and optical alignment within the selected 2 m maximum range, then chooses light/dark behavior for the required control condition.

Problem Solved

A discrete loop-level reference helps external feed logic coordinate material supply with available buffer space, using an optical interruption at an installed threshold.

Feed buffer Loop threshold Beam interruption
Select your currency