Skip to content

Contact Us:
sales@inosaki.com

SICK 1077674 GRL18S-N2436 M18 NPN Retro-reflective Sensor

SICK 1077674 GRL18S-N2436 M18 NPN Retro-reflective Sensor

USD 49.14

GRL18S-N2436 offers polarized 650 nm red-light sensing over 0.06–6 m with PL80A, complementary NPN outputs, no sensitivity adjustment and M12 connection.

SKU: SICK-1077674 Category:
SICK GR18S

SICK GRL18S-N2436 NPN Retro-reflective Sensor

BrandSICK
Model IdentifierGRL18S-N2436
Official Part Number1077674

Technical Overview

The SICK GRL18S-N2436 is a short M18 ×1 photoelectric retro-reflective sensor with axial optics and complementary NPN outputs. Its polarized 650 nm red PinPoint LED returns light from a passive reflector, with a minimum separation required by the dual-lens optics. With PL80A, sensing spans 0.06–6 m and maximum range is 0.03–7.2 m. There is no sensitivity adjustment. Response is below 500 µs with resistive load, with 1,000 Hz switching at a 1:1 light/dark ratio. The device uses 10–30 V DC and an M12 four-pin male connector. Its ABS housing and PMMA optics provide IP67 protection; two plastic fastening nuts support installation through an M18 mounting opening.

Short M18 polarized retro-reflective sensor with 0.06–6 m PL80A sensing, complementary NPN outputs, no sensitivity adjustment and M12 four-pin connection.

Key Features

  • Polarized retro-reflective sensing; minimum-distance dual-lens optics
  • M18 ×1 short cylindrical housing; axial optical axis
  • PL80A: 0.06–6 m sensing; 0.03–7.2 m maximum range
  • 650 nm red PinPoint LED; Ø175 mm spot at 7 m
  • No sensitivity adjustment; complementary NPN light/dark outputs
  • <500 µs response with resistive load; 1,000 Hz at 1:1 light/dark ratio
  • 10–30 V DC; ≤100 mA output, reduced to 50 mA above 24 V or +49 °C ambient
  • M12 four-pin male connector
  • ABS housing; PMMA optics; IP67; two plastic fastening nuts supplied

Monitor interruptions of a reflected red beam with short M18 axial optics and complementary NPN outputs for external process control.

Technical Specification Matrix

ParameterValue
Functional principlePolarized photoelectric retro-reflective sensor; dual-lens optics require minimum reflector distance
Housing designShort cylindrical M18 ×1 housing; axial optics
Sensing range0.06–6 m with PL80A reflector
Maximum sensing range0.03–7.2 m with PL80A reflector
Polarization filterYes
Light sourceVisible red PinPoint LED
Wavelength650 nm
Light spot sizeØ175 mm at 7 m
LED service lifeAverage 100,000 h at ambient +25 °C
AdjustmentNone
Switching outputNPN, complementary
Switching modeLight/dark switching through complementary outputs
Output current≤100 mA; maximum 50 mA at supply voltage >24 V or ambient temperature >49 °C
Response time<500 µs with resistive load
Switching frequency1,000 Hz at 1:1 light/dark ratio
Power supply10–30 V DC; limit values in a short-circuit-protected network, maximum 8 A
Ripple<5 Vpp; remain within supply tolerances
Current consumption30 mA
ConnectionM12 four-pin male connector
Pin assignmentCD-084: 1 BN=L+; 2 WH=Q̄; 3 BU=M; 4 BK=Q
Electrical protectionSupply reverse-polarity protection; input and output reverse-polarity protection; output overcurrent and short-circuit protection
Protection classIII
Housing materialABS
Optics materialPMMA
IP ratingIP67
Items suppliedTwo plastic fastening nuts; 22 mm hex
EMCEN 60947-5-2
Operating temperature−25 to +55 °C at supply voltage ≤24 V and output current <50 mA
Storage temperature−40 to +70 °C
UL filesNRKH.E348498 and NRKH7.E348498
IndicatorsGreen static on: power on; yellow static on: object absent; yellow off: object present
Reflector-specific rangesSensing / maximum: PL80A 0.06–6 / 0.03–7.2 m; PL40A 0.06–5.2 / 0.03–6.2 m; PL20A 0.06–2.9 / 0.03–3.8 m; P250 0.06–5.4 / 0.03–6.4 m; PL22 0.06–1.9 / 0.03–2.2 m; REF-Plus 3436 tape 0.08–1.6 / 0.06–2 m

Industrial Applications

1. Counting separated opaque loads across a conveyor

A conveyor can position the sensor opposite a compatible reflector so each separated opaque load interrupts the returned red beam. External counting logic reads the chosen complementary NPN output. Commissioning verifies reflector-specific sensing distances, alignment, load gaps and transit timing against the response-time and switching-frequency conditions.

Problem Solved

A returned-beam interruption provides external counting logic with a load-passage event, using commissioned reflector geometry and output behavior matched to the connected machine input.

Conveyor counting Reflector path NPN output

2. Monitoring opaque feed continuity

An opaque material feed can occupy the beam between the sensor and a compatible reflector. A gap or runout changes the received-light condition for external feed monitoring. Setup chooses the complementary output, aligns the reflector and checks that the material covers the optical path throughout normal movement, including the smallest interruption that must be recognized.

Problem Solved

A changed beam condition helps external feed monitoring identify missing material at the sensing point, using a verified optical path and selected switching behavior for the actual feed.

Feed continuity Opaque material Light/dark selection

3. Monitoring occupancy at a transfer point

A conveyor transfer can place the reflected beam through the location that must clear before another load is released. External sequencing logic distinguishes a brief passing interruption from sustained occupancy by evaluating output duration. Commissioning verifies the installed reflector distance, load coverage and the complementary output used, then tests the actual transfer sequence with representative loads.

Problem Solved

A sustained beam interruption supplies an occupancy reference to external sequencing logic, helping coordinate upstream load release when the monitored transfer location remains occupied.

Transfer occupancy External timing Reflector alignment