GLL170-P334 Fiber-Optic Sensors – SICK Sensor

$ 100.76

SKU: SICK 6063335

SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.

Part Number: 6063335
Fiber-Optic Sensor Model: GLL170-P334
OEM Spec Ref 

Features

Type Stand-alone
Dimensions (W x H x D) 10 mm x 31.7 mm x 72.5 mm
Housing design (light emission) Rectangular
Sensing range max. 0 mm … 190 mm, Proximity system 1) 2)

0 mm … 800 mm, Through-beam system 3)

Sensing range 0 mm … 160 mm, Proximity system 1) 2)

0 mm … 700 mm, Through-beam system 3)

Type of light Visible red light
Light source LED 4)
Wave length 632 nm
Adjustment Potentiometer, 8 turns 5)
Indication LED
Display Status LEDs
  • 1) Object with 90 % reflectance (referred to standard white, DIN 5033).
  • 2) LL3-DK06.
  • 3) LL3-TB02.
  • 4) Average service life: 100,000 h at TU = +25 °C.
  • 5) Sensitivity scale 230°.

 

Mechanics/electronics

Supply voltage 10 V DC … 30 V DC 1)
Ripple ≤ 10 % 2)
Switching output PNP
Number of switching outputs 1
Switching mode Light/dark switching
Switching mode selector Selectable via rotary switch
Output current Imax. ≤ 100 mA
Response time ≤ 250 µs 3)
Switching frequency 2 kHz
Time functions Without time delay

Off delay

Delay time Selectable via rotary switch, 0 ms … 40 ms
Connection type Male connector M8, 4-pin
Cable material PVC
Conductor cross-section 0.2 mm²
Cable diameter 3.8 mm
Circuit protection 4)

5)

6)

7)

Protection class III
Weight 19 g
Housing material Plastic, PC/POM
Tightening torque, max. 0.5 Nm
Enclosure rating IP66 8)
Ambient operating temperature –25 °C … +55 °C
Ambient storage temperature –40 °C … +70 °C
UL File No. NRKH2.E300503 & NRKH8.E300503
  • 1) Limit values.
  • 2) May not exceed or fall below Uv tolerances.
  • 3) Signal transit time with resistive load.
  • 4) A = VS connections reverse-polarity protected.
  • 5) B = inputs and output reverse-polarity protected.
  • 6) C = interference suppression.
  • 7) D = outputs overcurrent and short-circuit protected.
  • 8) With correctly attached fibre-optic cable LL3.

 

Safety-related parameters

MTTFD 760 years
DCavg 0%