Main body

When ordering, please specify the rated voltage.

Plug-in terminal type

Contact configuration 2c, 2a
classification format Rated voltage (V) Standard price (¥)
Standard form Model G7K-412S AC24 6,300
AC100
AC110
AC200
AC220
DC 24
DC48
DC 100
DC 110
DC 125

 

Note: A type with a built-in back electromotive force absorption diode is also available. Please contact us for details.

 

Rating

operation coil

Rated voltage (V) Rated current (mA) Coil resistance (Ω) Set
voltage (V)
Reset
voltage (V)
Maximum allowable
voltage (V)
Power consumption
(VA/W)
50Hz 60Hz Percentage of rated voltage
A.C. twenty four 94.6 84.3 86 80% or less 80% or less 110%
(115% 3h)
about 2
100 22.7 20.2 1,470
110 20.3 18.2 2,000
200 11.1 9.9 6,340
220 10.4 9.2 7,190
DC twenty four 36.5 660 110%
(130% 3h)
Approximately 0.9
48 18.4 2,610
100 8.9 11,300
110 8.4 13,000
125 7.1 17,700

 

Note 1. The rated current and coil resistance are the values ​​when the coil temperature is +23℃, and the tolerance is AC rated current +15%, -20%, DC coil resistance ±15%.
Note 2. AC coil resistance is a reference value.
Note 3. Operating characteristics are values ​​when the coil temperature is +23℃.
Note 4. The maximum allowable voltage is the maximum value of the allowable voltage fluctuation range of the relay coil operating power supply, and is the value at an ambient temperature of +23°C. Continuation is not allowed.

 

Opening/closing part

format Model G7K-412S
load resistive load Inductive load
(cosΦ = 0.4, L/R = 7ms)
contact mechanism single
Contact material Au plating + Ag
Rated load AC 220V 3A, DC 110V 1A AC 220V 1A, DC 30V 1A
Rated current 3A
Maximum value of contact voltage AC 250V, DC 125V
Maximum value of contact current 3A
Maximum switching capacity (reference value) 660VA 110W 220VA 30W

 

Performance

Contact resistance *1 50mΩ or less
Set *2 time 30ms or less
minimum pulse width 100ms
Reset *2 time 30ms or less
minimum pulse width 100ms
Maximum opening/closing frequency mechanical 1,800 times/h
Rated load 1,800 times/h
Insulation resistance *3 100MΩ or more
Withstand voltage Between contacts of the same polarity AC1,500V 50/60Hz 1min
Between contacts of different polarity AC2,000V 50/60Hz 1min
Between coil contacts AC2,000V 50/60Hz 1min
Between set and reset coils AC2,000V 50/60Hz 1min
vibration Durability 10~55~10Hz Single amplitude 0.375mm (Double amplitude 0.75mm)
malfunction 10~22~10Hz Single amplitude 0.5mm (double amplitude 1.0mm)
impact Durability 300m/s 2
malfunction 30m/s 2
durability mechanical More than 300,000 times (opening/closing frequency 1,800 times/h)
Electrical *4 100,000 times or more (opening/closing frequency 1,800 times/h)
Failure rate M level (reference value *5) DC 5V 10mA
Ambient temperature -10 to +55°C (no freezing or condensation)
Ambient humidity 5-85%RH
mass Approximately 175g

 

 

Note: The above values ​​are initial values.
*1. Measurement conditions: DC1V 10mA voltage drop method.
*2. Measurement conditions: When rated operating voltage is applied, contact bounce not included.
*3. Measurement conditions: Measured at the same location as in the withstand voltage section using a 500V DC insulation resistance meter.
*4. Ambient temperature condition: +23°C
*5. This value is at a switching frequency of 60 times/min.

Weight N/A