G3NA – For Heater Control – Omron Solid State Relays

$ 34.27$ 72.22

SKU: N/A

List of Models

Isolation Zero cross
function
Indicator Applicable output load
(See note 1.)
Rated input
voltage
Model
Phototriac Yes Yes 5 A at 24 to 240 VAC
(See note 2.)
5 to 24 VDC G3NA-205B-UTU DC5-24
Photocoupler 100 to 240 VAC G3NA-205B-UTU AC100-240
Phototriac 10 A at 24 to 240 VAC
(See note 2.)
5 to 24 VDC G3NA-210B-UTU DC5-24
Photocoupler 100 to 240 VAC G3NA-210B-UTU AC100-240
Phototriac 20 A at 24 to 240 VAC
(See note 2.)
5 to 24 VDC G3NA-220B-UTU DC5-24
Photocoupler 100 to 240 VAC G3NA-220B-UTU AC100-240
Phototriac 25 A at 24 to 240 VAC
(See note 2.)
5 to 24 VDC G3NA-225B-UTU DC5-24
Photocoupler 100 to 240 VAC G3NA-225B-UTU AC100-240
Phototriac 40 A at 24 to 240 VAC
(See note 2.)
5 to 24 VDC G3NA-240B-UTU DC5-24
Photocoupler 100 to 240 VAC G3NA-240B-UTU AC100-240
Phototriac 50 A at 24 to 240 VAC
(See note 2.)
5 to 24 VDC G3NA-250B-UTU DC5-24
Photocoupler 100 to 240 VAC G3NA-250B-UTU AC100-240
Phototriac 75 A at 24 to 240 VAC
(See note 2.)
5 to 24 VDC G3NA-275B-UTU-2 DC5-24
Photocoupler 100 to 240 VAC G3NA-275B-UTU-2 AC100-240
Phototriac 90 A at 24 to 240 VAC
(See note 2.)
5 to 24 VDC G3NA-290B-UTU-2 DC5-24
Photocoupler 100 to 240 VAC G3NA-290B-UTU-2 AC100-240
10 A at 200 to 480 VAC 5 to 24 VDC G3NA-410B-UTU DC5-24
100 to 240 VAC G3NA-410B-UTU AC100-240
20 A at 200 to 480 VAC 5 to 24 VDC G3NA-420B-UTU DC5-24
100 to 240 VAC G3NA-420B-UTU AC100-240
25 A at 200 to 480 VAC 5 to 24 VDC G3NA-425B-UTU-2 DC5-24
100 to 240 VAC G3NA-425B-UTU-2 AC100-240
40 A at 200 to 480 VAC 5 to 24 VDC G3NA-440B-UTU-2 DC5-24
100 to 240 VAC G3NA-440B-UTU-2 AC100-240
50 A at 200 to 480 VAC 5 to 24 VDC G3NA-450B-UTU-2 DC5-24
100 to 240 VAC G3NA-450B-UTU-2 AC100-240
75 A at 200 to 480 VAC 5 to 24 VDC G3NA-475B-UTU-2 DC5-24
100 to 240 VAC G3NA-475B-UTU-2 AC100-240
90 A at 200 to 480 VAC 5 to 24 VDC G3NA-490B-UTU-2 DC5-24
100 to 240 VAC G3NA-490B-UTU-2 AC100-240
10 A at 5 to 200 VDC 5 to 24 VDC G3NA-D210B-UTU DC5-24
100 to 240 VAC G3NA-D210B-UTU AC100-240

 

*All models are certified by UL, CSA, and TÜV.
Note: 1. The applicable load is the value for when the SSR is used with silicon grease applied to the specified heat sink. The
applicable load depends on the ambient temperature. Refer to Load Current vs. Ambient Temperature in
Engineering Data on Data Sheet.
2. Loss time increases under 75 VAC. (Refer to Data Sheet.) Confirm operation with the actual load.

 

Ratings

Input (at an Ambient Temperature of 25°C)

Model Rated voltage Operating
voltage
Impedance
(See note 1.)
Input current
Voltage level
Must operate
voltage
Must release
voltage
G3NA-2[][]B-UTU(-2)
G3NA-475B-UTU-2
G3NA-490B-UTU-2
5 to 24 VDC 4 to 32 VDC 7 mA max.
(See note 2.)
4 VDC max. 1 VDC min.
100 to 240 VAC 75 to 264 VAC 72 kΩ±20% 75 VAC max. 20 VAC min.
G3NA-410B-UTU
G3NA-420B-UTU
G3NA-425B-UTU-2
G3NA-440B-UTU-2
G3NA-450B-UTU-2
G3NA-D210B-UTU
5 to 24 VDC 4 to 32 VDC 5 mA max.
(See note 2.)
4 VDC max. 1 VDC min.
100 to 240 VAC 75 to 264 VAC 72 kΩ±20% 75 VAC max. 20 VAC min.

 

Note: 1. The input impedance is measured at the maximum value of the rated supply voltage (for example, with the model
rated at 100 to 240 VAC, the input impedance is measured at 240 VAC).
2. With constant current input circuit system.

 

Output

Model Applicable load
Rated
load
voltage
Load
voltage
range
Load current (See note 1.) Inrush current VDRM,
VCEO
(reference
value)
With heat sink
(See note 2.)
Without heat
sink
G3NA-205B-UTU 24 to
240
VAC
19 to
264
VAC
0.1 to 5 A (at 40°C) 0.1 to 3 A (at 40°C) 60 A (60 Hz, 1 cycle) 600 V
(VDRM)
G3NA-210B-UTU 0.1 to 10 A (at 40°C) 0.1 to 4 A (at 40°C) 150 A (60 Hz, 1 cycle)
G3NA-220B-UTU 0.1 to 20 A (at 40°C) 0.1 to 4 A (at 40°C) 220 A (60 Hz, 1 cycle)
G3NA-225B-UTU 0.1 to 25 A (at 40°C) 0.1 to 4 A (at 40°C) 220 A (60 Hz, 1 cycle)
G3NA-240B-UTU 0.1 to 40 A (at 40°C) 0.1 to 6 A (at 40°C) 440 A (60 Hz, 1 cycle)
G3NA-250B-UTU 0.1 to 50 A (at 40°C) 0.1 to 6 A (at 40°C) 440 A (60 Hz, 1 cycle)
G3NA-275B-UTU-2 1 to 75 A (at 40°C) 1 to 7 A (at 40°C) 800 A (60 Hz, 1 cycle)
G3NA-290B-UTU-2 1 to 90 A (at 40°C) 1 to 7 A (at 40°C) 1,000 A (60 Hz, 1 cycle)
G3NA-410B-UTU 200 to
480
VAC
180 to
528
VAC
0.2 to 10 A (at 40°C) 0.2 to 4 A (at 40°C) 150 A (60 Hz, 1 cycle) 1,200 V
(VDRM)
G3NA-420B-UTU 0.2 to 20 A (at 40°C) 0.2 to 4 A (at 40°C) 220 A (60 Hz, 1 cycle)
G3NA-425B-UTU-2 0.2 to 25 A (at 40°C) 0.2 to 4 A (at 40°C) 220 A (60 Hz, 1 cycle)
G3NA-440B-UTU-2 0.2 to 40 A (at 40°C) 0.2 to 6 A (at 40°C) 440 A (60 Hz, 1 cycle)
G3NA-450B-UTU-2 0.2 to 50 A (at 40°C) 0.2 to 6 A (at 40°C) 440 A (60 Hz, 1 cycle)
G3NA-475B-UTU-2 1 to 75 A (at 40°C) 1 to 7 A (at 40°C) 800 A (60 Hz, 1 cycle)
G3NA-490B-UTU-2 1 to 90 A (at 40°C) 1 to 7 A (at 40°C) 1,000 A (60 Hz, 1 cycle)
G3NA-D210B-UTU 5 to
200
VDC
4 to
220
VDC
0.1 to 10 A (at 40°C) 0.1 to 4 A (at 40°C) 20 A (10 ms) 400 V
(VCEO)

 

 

Note: 1. The load current varies depending on the ambient temperature. Refer to Load Current vs. Ambient Temperature
under Engineering Data on Data Sheet.
2. When an OMRON Heat Sink (refer to Options (Order Separately)) or a heat sink of the specified size is used.

 

Characteristics

Item G3NA-
205B-
UTU
G3NA-
210B-
UTU
G3NA-
220B-
UTU
G3NA-
225B-
UTU
G3NA-
240B-
UTU
G3NA-
250B-
UTU
G3NA-
275B-
UTU-2
G3NA-
290B-
UTU-2
Operate time 1/2 of load power source cycle + 1 ms max. (DC input)
3/2 of load power source cycle + 1 ms max. (AC input)
Release time 1/2 of load power source cycle + 1 ms max. (DC input)
3/2 of load power source cycle + 1 ms max. (AC input)
Output ON voltage
drop
1.6 V (RMS) max.
Leakage current 5 mA max. (at 100 VAC)
10 mA max. (at 200 VAC)
Insulation resistance 100 MΩ min. (at 500 VDC)
Dielectric strength 2,500 VAC, 50/60 Hz for 1 min
Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Shock resistance Destruction: 1,000 m/s2
Ambient temperature Operating:-30°C to 80°C (with no icing or condensation)
Storage:-30°C to 100°C (with no icing or condensation)
Ambient humidity Operating: 45% to 85%
Weight Approx. 60 g Approx. 70 g Approx. 120 g

 

Item G3NA-
410B-
UTU
G3NA-
420B-
UTU
G3NA-
425B-
UTU-2
G3NA-
440B-
UTU-2
G3NA-
450B-
UTU-2
G3NA-
475B-
UTU-2
G3NA-
490B-
UTU-2
G3NA-
D210B-UTU
Operate time 1/2 of load power source cycle + 1 ms max. (DC input)
3/2 of load power source cycle + 1 ms max. (AC input)
1 ms max. (DC input)
30 ms max. (AC input)
Release time 1/2 of load power source cycle + 1 ms max. (DC input)
3/2 of load power source cycle + 1 ms max. (AC input)
5 ms max. (DC input)
30 ms max. (AC input)
Output ON voltage
drop
1.8 V (RMS) max. 1.5 V max.
Leakage current 10 mA max. (at 200 VAC)
20 mA max. (at 400 VAC)
5 mA max.
(at 200 VDC)
Insulation resistance 100 MΩ min. (at 500 VDC)
Dielectric strength 4,000 VAC, 50/60 Hz for 1 min 2,500 VAC, 50/60 Hz
for 1 min
Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Shock resistance Destruction: 1,000 m/s2
Ambient
temperature
Operating:-30°C to 80°C (with no icing or condensation)
Storage:-30°C to 100°C (with no icing or condensation)
Ambient humidity Operating: 45% to 85%
Weight Approx. 80 g Approx. 120 g Approx. 70 g
Weight N/A
Model

G3NA-275B-UTU-2 DC5-24, G3NA-D210B-UTU DC5-24

Related products