rated at 100 to 240 VAC, the input impedance is measured at 240 VAC).
2. With constant current input circuit system.
$ 32.78 – $ 69.08
Isolation | Zero cross function |
Indicator | Applicable output load (See note 1.) |
Rated input voltage |
Model |
---|---|---|---|---|---|
Phototriac | Yes | Yes | 5 A at 24 to 240 VAC (See note 2.) |
5 to 24 VDC | G3NA-205B-UTU DC5-24 |
Photocoupler | 100 to 240 VAC | G3NA-205B-UTU AC100-240 | |||
Phototriac | 10 A at 24 to 240 VAC (See note 2.) |
5 to 24 VDC | G3NA-210B-UTU DC5-24 | ||
Photocoupler | 100 to 240 VAC | G3NA-210B-UTU AC100-240 | |||
Phototriac | 20 A at 24 to 240 VAC (See note 2.) |
5 to 24 VDC | G3NA-220B-UTU DC5-24 | ||
Photocoupler | 100 to 240 VAC | G3NA-220B-UTU AC100-240 | |||
Phototriac | 25 A at 24 to 240 VAC (See note 2.) |
5 to 24 VDC | G3NA-225B-UTU DC5-24 | ||
Photocoupler | 100 to 240 VAC | G3NA-225B-UTU AC100-240 | |||
Phototriac | 40 A at 24 to 240 VAC (See note 2.) |
5 to 24 VDC | G3NA-240B-UTU DC5-24 | ||
Photocoupler | 100 to 240 VAC | G3NA-240B-UTU AC100-240 | |||
Phototriac | 50 A at 24 to 240 VAC (See note 2.) |
5 to 24 VDC | G3NA-250B-UTU DC5-24 | ||
Photocoupler | 100 to 240 VAC | G3NA-250B-UTU AC100-240 | |||
Phototriac | 75 A at 24 to 240 VAC (See note 2.) |
5 to 24 VDC | G3NA-275B-UTU-2 DC5-24 | ||
Photocoupler | 100 to 240 VAC | G3NA-275B-UTU-2 AC100-240 | |||
Phototriac | 90 A at 24 to 240 VAC (See note 2.) |
5 to 24 VDC | G3NA-290B-UTU-2 DC5-24 | ||
Photocoupler | 100 to 240 VAC | G3NA-290B-UTU-2 AC100-240 | |||
10 A at 200 to 480 VAC | 5 to 24 VDC | G3NA-410B-UTU DC5-24 | |||
100 to 240 VAC | G3NA-410B-UTU AC100-240 | ||||
20 A at 200 to 480 VAC | 5 to 24 VDC | G3NA-420B-UTU DC5-24 | |||
100 to 240 VAC | G3NA-420B-UTU AC100-240 | ||||
25 A at 200 to 480 VAC | 5 to 24 VDC | G3NA-425B-UTU-2 DC5-24 | |||
100 to 240 VAC | G3NA-425B-UTU-2 AC100-240 | ||||
40 A at 200 to 480 VAC | 5 to 24 VDC | G3NA-440B-UTU-2 DC5-24 | |||
100 to 240 VAC | G3NA-440B-UTU-2 AC100-240 | ||||
50 A at 200 to 480 VAC | 5 to 24 VDC | G3NA-450B-UTU-2 DC5-24 | |||
100 to 240 VAC | G3NA-450B-UTU-2 AC100-240 | ||||
75 A at 200 to 480 VAC | 5 to 24 VDC | G3NA-475B-UTU-2 DC5-24 | |||
100 to 240 VAC | G3NA-475B-UTU-2 AC100-240 | ||||
90 A at 200 to 480 VAC | 5 to 24 VDC | G3NA-490B-UTU-2 DC5-24 | |||
100 to 240 VAC | G3NA-490B-UTU-2 AC100-240 | ||||
— | 10 A at 5 to 200 VDC | 5 to 24 VDC | G3NA-D210B-UTU DC5-24 | ||
100 to 240 VAC | G3NA-D210B-UTU AC100-240 |
*All models are certified by UL, CSA, and TÜV.
Note: 1. The applicable load is the value for when the SSR is used with silicon grease applied to the specified heat sink. The
applicable load depends on the ambient temperature. Refer to Load Current vs. Ambient Temperature in
Engineering Data on Data Sheet.
2. Loss time increases under 75 VAC. (Refer to Data Sheet.) Confirm operation with the actual load.
Model | Rated voltage | Operating voltage |
Impedance (See note 1.) Input current |
Voltage level | |
---|---|---|---|---|---|
Must operate voltage |
Must release voltage |
||||
G3NA-2[][]B-UTU(-2) G3NA-475B-UTU-2 G3NA-490B-UTU-2 |
5 to 24 VDC | 4 to 32 VDC | 7 mA max. (See note 2.) |
4 VDC max. | 1 VDC min. |
100 to 240 VAC | 75 to 264 VAC | 72 kΩ±20% | 75 VAC max. | 20 VAC min. | |
G3NA-410B-UTU G3NA-420B-UTU G3NA-425B-UTU-2 G3NA-440B-UTU-2 G3NA-450B-UTU-2 G3NA-D210B-UTU |
5 to 24 VDC | 4 to 32 VDC | 5 mA max. (See note 2.) |
4 VDC max. | 1 VDC min. |
100 to 240 VAC | 75 to 264 VAC | 72 kΩ±20% | 75 VAC max. | 20 VAC min. |
Model | Applicable load | |||||
---|---|---|---|---|---|---|
Rated load voltage |
Load voltage range |
Load current (See note 1.) | Inrush current | VDRM, VCEO (reference value) |
||
With heat sink (See note 2.) |
Without heat sink |
|||||
G3NA-205B-UTU | 24 to 240 VAC |
19 to 264 VAC |
0.1 to 5 A (at 40°C) | 0.1 to 3 A (at 40°C) | 60 A (60 Hz, 1 cycle) | 600 V (VDRM) |
G3NA-210B-UTU | 0.1 to 10 A (at 40°C) | 0.1 to 4 A (at 40°C) | 150 A (60 Hz, 1 cycle) | |||
G3NA-220B-UTU | 0.1 to 20 A (at 40°C) | 0.1 to 4 A (at 40°C) | 220 A (60 Hz, 1 cycle) | |||
G3NA-225B-UTU | 0.1 to 25 A (at 40°C) | 0.1 to 4 A (at 40°C) | 220 A (60 Hz, 1 cycle) | |||
G3NA-240B-UTU | 0.1 to 40 A (at 40°C) | 0.1 to 6 A (at 40°C) | 440 A (60 Hz, 1 cycle) | |||
G3NA-250B-UTU | 0.1 to 50 A (at 40°C) | 0.1 to 6 A (at 40°C) | 440 A (60 Hz, 1 cycle) | |||
G3NA-275B-UTU-2 | 1 to 75 A (at 40°C) | 1 to 7 A (at 40°C) | 800 A (60 Hz, 1 cycle) | |||
G3NA-290B-UTU-2 | 1 to 90 A (at 40°C) | 1 to 7 A (at 40°C) | 1,000 A (60 Hz, 1 cycle) | |||
G3NA-410B-UTU | 200 to 480 VAC |
180 to 528 VAC |
0.2 to 10 A (at 40°C) | 0.2 to 4 A (at 40°C) | 150 A (60 Hz, 1 cycle) | 1,200 V (VDRM) |
G3NA-420B-UTU | 0.2 to 20 A (at 40°C) | 0.2 to 4 A (at 40°C) | 220 A (60 Hz, 1 cycle) | |||
G3NA-425B-UTU-2 | 0.2 to 25 A (at 40°C) | 0.2 to 4 A (at 40°C) | 220 A (60 Hz, 1 cycle) | |||
G3NA-440B-UTU-2 | 0.2 to 40 A (at 40°C) | 0.2 to 6 A (at 40°C) | 440 A (60 Hz, 1 cycle) | |||
G3NA-450B-UTU-2 | 0.2 to 50 A (at 40°C) | 0.2 to 6 A (at 40°C) | 440 A (60 Hz, 1 cycle) | |||
G3NA-475B-UTU-2 | 1 to 75 A (at 40°C) | 1 to 7 A (at 40°C) | 800 A (60 Hz, 1 cycle) | |||
G3NA-490B-UTU-2 | 1 to 90 A (at 40°C) | 1 to 7 A (at 40°C) | 1,000 A (60 Hz, 1 cycle) | |||
G3NA-D210B-UTU | 5 to 200 VDC |
4 to 220 VDC |
0.1 to 10 A (at 40°C) | 0.1 to 4 A (at 40°C) | 20 A (10 ms) | 400 V (VCEO) |
Characteristics
Item | G3NA- 205B- UTU |
G3NA- 210B- UTU |
G3NA- 220B- UTU |
G3NA- 225B- UTU |
G3NA- 240B- UTU |
G3NA- 250B- UTU |
G3NA- 275B- UTU-2 |
G3NA- 290B- UTU-2 |
---|---|---|---|---|---|---|---|---|
Operate time | 1/2 of load power source cycle + 1 ms max. (DC input) 3/2 of load power source cycle + 1 ms max. (AC input) |
|||||||
Release time | 1/2 of load power source cycle + 1 ms max. (DC input) 3/2 of load power source cycle + 1 ms max. (AC input) |
|||||||
Output ON voltage drop |
1.6 V (RMS) max. | |||||||
Leakage current | 5 mA max. (at 100 VAC) 10 mA max. (at 200 VAC) |
|||||||
Insulation resistance | 100 MΩ min. (at 500 VDC) | |||||||
Dielectric strength | 2,500 VAC, 50/60 Hz for 1 min | |||||||
Vibration resistance | Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) | |||||||
Shock resistance | Destruction: 1,000 m/s2 | |||||||
Ambient temperature | Operating:-30°C to 80°C (with no icing or condensation) Storage:-30°C to 100°C (with no icing or condensation) |
|||||||
Ambient humidity | Operating: 45% to 85% | |||||||
Weight | Approx. 60 g | Approx. 70 g | Approx. 120 g |
Item | G3NA- 410B- UTU |
G3NA- 420B- UTU |
G3NA- 425B- UTU-2 |
G3NA- 440B- UTU-2 |
G3NA- 450B- UTU-2 |
G3NA- 475B- UTU-2 |
G3NA- 490B- UTU-2 |
G3NA- D210B-UTU |
---|---|---|---|---|---|---|---|---|
Operate time | 1/2 of load power source cycle + 1 ms max. (DC input) 3/2 of load power source cycle + 1 ms max. (AC input) |
1 ms max. (DC input) 30 ms max. (AC input) |
||||||
Release time | 1/2 of load power source cycle + 1 ms max. (DC input) 3/2 of load power source cycle + 1 ms max. (AC input) |
5 ms max. (DC input) 30 ms max. (AC input) |
||||||
Output ON voltage drop |
1.8 V (RMS) max. | 1.5 V max. | ||||||
Leakage current | 10 mA max. (at 200 VAC) 20 mA max. (at 400 VAC) |
5 mA max. (at 200 VDC) |
||||||
Insulation resistance | 100 MΩ min. (at 500 VDC) | |||||||
Dielectric strength | 4,000 VAC, 50/60 Hz for 1 min | 2,500 VAC, 50/60 Hz for 1 min |
||||||
Vibration resistance | Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) | |||||||
Shock resistance | Destruction: 1,000 m/s2 | |||||||
Ambient temperature |
Operating:-30°C to 80°C (with no icing or condensation) Storage:-30°C to 100°C (with no icing or condensation) |
|||||||
Ambient humidity | Operating: 45% to 85% | |||||||
Weight | Approx. 80 g | Approx. 120 g | Approx. 70 g |
Weight | N/A |
---|---|
Model |
INOSAKI Limited
RM B 5/F Gaylord Comm,
Bldg 114-118 Lockhart Rd.
Hong Kong
INOSAKI Sdn. Bhd.
2-1-9, Ground Floor, One Square, Tingkat Mahsuri 1,
11900 Bayan Lepas, Penan
INOSAKI Pte. Ltd.
101 Upper Cross Street,
No. 06-17, People’s Park Centre,
Singapore (058357)