FP-X RTD CASSETTE 2CH – AFPX-RTD2 – Panasonic
$ 160.60
SKU: N/A
FP-X RTD CASSETTE 2CH – AFPX-RTD2
Applicable Products–Programmable Controllers / Interface Terminal-FP-X
Specifications
Item | Description | ||||
---|---|---|---|---|---|
C14 | C30 | C60 | |||
Number of controllable I/O points |
Control unit | Relay output type | DC input: 8, relay output: 6 | DC input: 16, relay output: 14 | DC input: 32, relay output: 28 |
Transistor output type | DC input: 8, transistor output: 6 | DC input: 16, transistor output: 14 | DC input: 32, transistor output: 28 | ||
Max. I/O points when expanded | 254 points (328 points max. when using add-on cassettes and FP0R expansion units) |
270 points (352 points max. when using add-on cassettes and FP0R expansion units) |
300 points (382 points max. when using add-on cassettes and FP0R expansion units) |
||
Programming method / Control method | Relay symbol / Cyclic operation | ||||
Program memory | Built-in flash ROM (no backup battery required) | ||||
Program capacity | 16 k steps | 32 k steps | 32 k steps | ||
Number of instructions |
Basic instructions | 89 | |||
High-level instructions | 226 | ||||
Operation speed | Basic instruction: 0.32 μs~/step | ||||
I/O refresh + base time | 0.2 ms [When using FP0R expansion units: 1 ms + (1.5 × Number of expansion units) ms] | ||||
Operation memory | Relay | External inputs (X) | 1,760 points (The actual usable number of points is restricted by the hardware.) | ||
External outputs (Y) | 1,760 points (The actual usable number of points is restricted by the hardware.) | ||||
Internal relay (X) | 4,096 points (R0 to R255F) | ||||
Special internal relay (R) | 192 points | ||||
Timer / counter (T/C) | 1,024 points: timer capable of counting (1 ms, 10 ms, 100 ms, 1 sec.) × 32,767, Counter capable of counting 1 to 32,767 | ||||
Link relay (L) | 2,048 points | ||||
Memory area |
IMemory area Data register |
-12,285 words (DT0 to DT12284) | 32,765 words (DT0 to DT32764) | ||
Special data register (DT) | 374 words | ||||
Link register (LD) | 256 words | ||||
Index register (I) | 14 words | ||||
High-speed counter (Note 1) | Built-in (Transistor output): single-phase 8 ch (50 kHz × 4 ch + 10 kHz × 4 ch) Built-in (Relay output): single-phase 8 ch (10 kHz × 8 ch) Pulse I/O cassette: single-phase 2 ch (80 kHz × 2 ch) |
||||
Pulse output (Note 2) / PWM output | Built-in (Transistor output): 100 kHz × 2 ch + 20 kHz × 2 ch Pulse I/O cassette: One unit (one axis) 100 kHz, or two units (two axes) 80 kHz |
||||
Time measurement | 10 μs ring counter | ||||
Potentiometer | 2 points (K0 to K1000) | 2 points (K0 to K1000) | 4 points (K0 to K1000) | ||
Constant scan | Available | ||||
Clock / calendar | When AFPX-MRTC is attached: Year (last two digits), month, day, hours (24-hour display), minutes, seconds, day of week. Operates only when a battery is installed. |
||||
Flash ROM backup |
Backup by P13 commands | Data register (32,765 words) | |||
Auto-backup at power failure | Counter 16 points (1008 to 1023), Internal relay 128 points (R2480 to R255F), Data register 55 words (C30 / C60 = 32710 to 32764, C14 = 12230 to 12284) |
||||
Battery backup | The memory allocated in the storage area by the system register (only when a battery is installed) |
Notes:
1) Specification at the rated input voltage of 24 V DC, +25 ℃ +77 ℉. Frequency may be lower due to the voltage and temperature.
2) Max. frequency may vary by the method of operation. Please refer to the manual for details.
Related products
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details