F3SJ-E[][][][]N25 – Omron Safety Light Curtains

$ 300.08$ 935.00

SKU: N/A

F3SJ-E

Main Units

Safety Light Curtain

Application Detection
capability
Beam gap Operating range Protective height
(mm)
Model
PNP output NPN output
Hand protection Dia. 25 mm 20 mm 0.2 to 7 m 185 to 1,105 F3SJ-E[][][][]P25 * F3SJ-E[][][][]N25

 

Note: F3SJ-E uses a 3 m prewired discrete cable.
*1. For S-mark compatible model, the suffix “-S” is added to the model name.
(Example) F3SJ-E0185P25-S

 

Safety Light Curtain Model List

F3SJ-E Series (20 mm pitch)

Model Number of beams Protective height [mm] *2
PNP output *1 NPN output
F3SJ-E0185P25 F3SJ-E0185N25 8 185
F3SJ-E0225P25 F3SJ-E0225N25 10 225
F3SJ-E0305P25 F3SJ-E0305N25 14 305
F3SJ-E0385P25 F3SJ-E0385N25 18 385
F3SJ-E0465P25 F3SJ-E0465N25 22 465
F3SJ-E0545P25 F3SJ-E0545N25 26 545
F3SJ-E0625P25 F3SJ-E0625N25 30 625
F3SJ-E0705P25 F3SJ-E0705N25 34 705
F3SJ-E0785P25 F3SJ-E0785N25 38 785
F3SJ-E0865P25 F3SJ-E0865N25 42 865
F3SJ-E0945P25 F3SJ-E0945N25 46 945
F3SJ-E1025P25 F3SJ-E1025N25 50 1,025
F3SJ-E1105P25 F3SJ-E1105N25 54 1,105

 

*1. For S-mark compatible model, the suffix “-S” is added to the model name.
(Example) F3SJ-E0185P25-S
*2. Protective height (mm) = Total sensor length

 

Specifications

Model PNP output F3SJ-E[][][][]P25
NPN output F3SJ-E[][][][]P25
Sensor type Type 4 safety light curtain
Setting tool connection *1 Parameter settings: Not available
Safety category Safety purpose of category 4, 3, 2, 1, or B
Detection capability Opaque objects 25 mm in diameter
Beam gap (P) 20 mm
Number of beams (n) 8 to 54
Protective height (PH) 185 to 1,105 mm
Lens diameter Diameter 5 mm
Operating range *2 0.2 to 7 m
Response time
(under stable
light incident
condition)
ON to OFF 15 ms max.
OFF to ON 70 ms max.
Startup waiting time 2 s max.
Power supply voltage (Vs) SELV/PELV 24 VDC±20% (ripple p-p 10% max.)
Consumption
current
(no load)
PNP output Emitter: Up to 22 beams: 41 mA max., 26 to 42 beams: 57 mA max., 46 to 54 beams:
63 mA max.
Receiver: Up to 22 beams: 42 mA max., 26 to 42 beams: 47 mA max., 46 to 54 beams:
51 mA max.
NPN output Emitter: Up to 22 beams: 41 mA max., 26 to 42 beams: 57 mA max., 46 to 54 beams:
63 mA max.
Receiver: Up to 22 beams: 40 mA max., 26 to 42 beams: 45 mA max., 46 to 54 beams:
48 mA max.
Light source (emitted
wavelength)
Infrared LED (870 nm)
Effective aperture angle
(EAA)
Based on IEC 61496-2. Within ±2.5° for both emitter and receiver when the
detection distance is 3 m or over
Safety outputs
(OSSD)
PNP output Two PNP transistor outputs, load current 200 mA max., residual voltage 2 V max.
(except for voltage drop due to cable extension), Leakage current 1 mA max., load
inductance 2.2 H max. *3, Maximum capacity load 1 μF *4
NPN output Two NPN transistor outputs, load current 200 mA max., residual voltage 2 V max.
(except for voltage drop due to cable extension), Leakage current 1 mA max., load
inductance 2.2 H max. *3, Maximum capacity load 1 μF *4
Output operation mode Safety output: On when receiving light
Input voltage PNP output Test input:
ON voltage: Vs-3 V to Vs (short circuit current: approx. 3.0 mA) *5
OFF voltage: 0 V to 1/2 Vs or open (short circuit current: approx. 4.0 mA) *5
NPN output Test input:
ON voltage: 0 to 3 V (short circuit current: approx. 4.0 mA)
OFF voltage: 1/2 Vs to Vs or open (short circuit current: approx. 3.0 mA) *5
Mutual interference
prevention function
Mutual interference prevention algorithm prevents interference in up to 3 sets.
Test function Self test (at power-ON and at power distribution)
External test (emission stop function by test input)
Protection circuit Output short-circuit protection, and power supply reverse polarity protection
Ambient temperature Operating: -10 to 55°C (non-freezing), Storage: -25 to 70°C
Ambient humidity Operating: 35% to 85% (no condensation), Storage: 35% to 95% RH
Operating ambient light
intensity
Incandescent lamp: 3,000 lx max., Sunlight: 10,000 lx max.
Insulation resistance 20 MΩ min. (at 500 VDC)
Dielectric strength 1,000 VAC 50/60 Hz, 1 min
Degree of protection IP65 (IEC 60529)
Vibration resistance Class 3M4 (IEC TR 60721-4-3)
Operation limit: 5 to 150 Hz, Multiple amplitude of 7 mm, Acceleration of 1 G, 10 sweeps each in X, Y, and Z
directions (no delay at resonant frequencies)
Shock resistance Class 3M4 (IEC TR 60721-4-3)
Operation limit: Acceleration of 15 G, Pulse duration of 6 ms, 100 shocks for each in X, Y, and Z directions (600 shocks in total)
Pollution degree Pollution degree 3 (IEC 60664-1)
Power cable Connection method: Pull-out type, cable length 3 m
Number of wires: Emitter: 5 wires, receiver: 6 wires
Cable diameter: Dia. 6 mm
Allowable bending radius: R5 mm
Extension cable 30 m max. *6
Material Case: Aluminum
Cap: ABS resin, PBT
Optical cover: PMMA resin (acrylic)
Cable: Oil resistant PVC
Net Weight *7 Weight (g) = (protective height) x 1.59 + 330
Gross Weight *8 Weight (g) = (protective height) x 2.6 + 800
Accessories Instruction Manual, Quick Installation Manual (QIM) *9
Applicable standards *10 IEC 61496-1, EN 61496-1, UL 61496-1, Type 4 ESPE (Electro-Sensitive Protective
Equipment)
IEC 61496-2, EN 61496-2, UL 61496-2, Type 4 AOPD (Active Opto-electronic
Protective Devices)
IEC 61508-1 to -3, EN 61508-1 to -3 SIL3
ISO 13849-1: 2015, EN ISO 13849-1: 2015 (PLe/Safety Category 4)
UL 508, UL 1998, CAN/CSA C22.2 No.14, CAN/CSA C22.2 No.0.8

 

*1. Do not use the Support Software and Setting Console for F3SJ-A. Operation cannot be guaranteed.
*2. Use of the Spatter Protection Cover causes a 10% maximum sensing distance attenuation.
*3. The load inductance is the maximum value when the safety output frequently repeats ON and OFF. When you use the
safety output at 4 Hz or less, the usable load inductance becomes larger.
*4. These values must be taken into consideration when connecting elements including a capacitive load such as capacitor.
*5. The Vs indicates a voltage value in your environment.
*6. To extend a cable of the F3SJ-E, refer to the User’s Manual (SCHG-733/732).
*7. The net weight is the weight of an emitter and a receiver.
*8. The gross weight is the weight of an emitter, a receiver, included accessories and a package.
*9. Mounting brackets and test rod are sold separately.
*10.Refer to Safety Precautions for information about Legislation and Standards.

 

Indicator

Emitter

Nameofindicator Label ON Blinking
Top-beam-state
indicator
TOP Turns ON when the top beam is
receiving light.
Stable-state
indicator
STB Turns ON when incidence level is more
than 170% of the output ON threshold.
Blinks when the safety output is turned
OFF due to disturbance light or vibration.
ON/OFF-state
indicator
ON
OFF
Green: Turns ON when safety output is ON.
Red: Turns OFF when safety output is OFF.
Red: Blinks when the F3SJ-E enters a
lockout due to a safety output error.
Lockout indicator LOCKOUT Turns ON when the F3SJ-E enters a
lockout on the receiver.
Blinks when the F3SJ-E enters a lockout
on the emitter.
Power indicator POWER Turns ON while the power of the
emitter is ON.
Blinks when the F3SJ-E enters a lockout
due to power voltage/noise.
Test indicator TEST Blinks when external test is being
performed.
Bottom-beam-
state indicator
BTM Turns ON when the bottom beam is
receiving light.

 

Receiver

Nameofindicator Label ON Blinking
Top-beam-state
indicator
TOP Turns ON when the top beam is receiving
light.
Stable-state
indicator
STB Turns ON when incidence level is more
than 170% of the output ON threshold.
Blinks when the safety output is turned
OFF due to disturbance light or vibration.
ON/OFF-state
indicator
ON
OFF
Green: Turns ON when safety output is ON.
Red: Turns OFF when safety output is OFF.
Red: Blinks when the F3SJ-E enters a
lockout due to a safety output error.
Lockout indicator LOCKOUT Turns ON when the F3SJ-E enters a
lockout on the emitter.
Blinks when the F3SJ-E enters a lockout
on the receiver.
Communication
indicator
COM Turns ON when communication between
emitter and receiver is established.
Blinks when the F3SJ-E enters lockout
due to a communication error between
receiver and emitter.
Configuration
indicator
CFG Blinks when the F3SJ-E enters lockout
due to a model type error between
receiver and emitter.
Internal error
indicator
INTERNAL Blinks when the F3SJ-E enters a lockout
due to an internal error.
Bottom-beam-
state indicator
BTM Turns ON when the bottom beam is
receiving light.

 

Model

F3SJ-E0185N25, F3SJ-E0225N25, F3SJ-E0305N25, F3SJ-E0385N25, F3SJ-E0465N25, F3SJ-E0545N25, F3SJ-E0545P25, F3SJ-E0625N25, F3SJ-E0705N25, F3SJ-E0785N25, F3SJ-E0865N25, F3SJ-E0865P25, F3SJ-E0945N25, F3SJ-E0945P25, F3SJ-E1025N25, F3SJ-E1025P25, F3SJ-E1105N25, F3SJ-E1105P25

Related products