F3SJ-E[][][][]N25 – Omron Safety Light Curtains
$ 300.08 – $ 935.00
F3SJ-E
Main Units
Safety Light Curtain
Application | Detection capability |
Beam gap | Operating range | Protective height (mm) |
Model | |
---|---|---|---|---|---|---|
PNP output | NPN output | |||||
Hand protection | Dia. 25 mm | 20 mm | 0.2 to 7 m | 185 to 1,105 | F3SJ-E[][][][]P25 * | F3SJ-E[][][][]N25 |
*1. For S-mark compatible model, the suffix “-S” is added to the model name.
(Example) F3SJ-E0185P25-S
Safety Light Curtain Model List
F3SJ-E Series (20 mm pitch)
Model | Number of beams | Protective height [mm] *2 | |
---|---|---|---|
PNP output *1 | NPN output | ||
F3SJ-E0185P25 | F3SJ-E0185N25 | 8 | 185 |
F3SJ-E0225P25 | F3SJ-E0225N25 | 10 | 225 |
F3SJ-E0305P25 | F3SJ-E0305N25 | 14 | 305 |
F3SJ-E0385P25 | F3SJ-E0385N25 | 18 | 385 |
F3SJ-E0465P25 | F3SJ-E0465N25 | 22 | 465 |
F3SJ-E0545P25 | F3SJ-E0545N25 | 26 | 545 |
F3SJ-E0625P25 | F3SJ-E0625N25 | 30 | 625 |
F3SJ-E0705P25 | F3SJ-E0705N25 | 34 | 705 |
F3SJ-E0785P25 | F3SJ-E0785N25 | 38 | 785 |
F3SJ-E0865P25 | F3SJ-E0865N25 | 42 | 865 |
F3SJ-E0945P25 | F3SJ-E0945N25 | 46 | 945 |
F3SJ-E1025P25 | F3SJ-E1025N25 | 50 | 1,025 |
F3SJ-E1105P25 | F3SJ-E1105N25 | 54 | 1,105 |
*1. For S-mark compatible model, the suffix “-S” is added to the model name.
(Example) F3SJ-E0185P25-S
*2. Protective height (mm) = Total sensor length
Specifications
Model | PNP output | F3SJ-E[][][][]P25 |
---|---|---|
NPN output | F3SJ-E[][][][]P25 | |
Sensor type | Type 4 safety light curtain | |
Setting tool connection *1 | Parameter settings: Not available | |
Safety category | Safety purpose of category 4, 3, 2, 1, or B | |
Detection capability | Opaque objects 25 mm in diameter | |
Beam gap (P) | 20 mm | |
Number of beams (n) | 8 to 54 | |
Protective height (PH) | 185 to 1,105 mm | |
Lens diameter | Diameter 5 mm | |
Operating range *2 | 0.2 to 7 m | |
Response time (under stable light incident condition) |
ON to OFF | 15 ms max. |
OFF to ON | 70 ms max. | |
Startup waiting time | 2 s max. | |
Power supply voltage (Vs) | SELV/PELV 24 VDC±20% (ripple p-p 10% max.) | |
Consumption current (no load) |
PNP output | Emitter: Up to 22 beams: 41 mA max., 26 to 42 beams: 57 mA max., 46 to 54 beams: 63 mA max. Receiver: Up to 22 beams: 42 mA max., 26 to 42 beams: 47 mA max., 46 to 54 beams: 51 mA max. |
NPN output | Emitter: Up to 22 beams: 41 mA max., 26 to 42 beams: 57 mA max., 46 to 54 beams: 63 mA max. Receiver: Up to 22 beams: 40 mA max., 26 to 42 beams: 45 mA max., 46 to 54 beams: 48 mA max. |
|
Light source (emitted wavelength) |
Infrared LED (870 nm) | |
Effective aperture angle (EAA) |
Based on IEC 61496-2. Within ±2.5° for both emitter and receiver when the detection distance is 3 m or over |
|
Safety outputs (OSSD) |
PNP output | Two PNP transistor outputs, load current 200 mA max., residual voltage 2 V max. (except for voltage drop due to cable extension), Leakage current 1 mA max., load inductance 2.2 H max. *3, Maximum capacity load 1 μF *4 |
NPN output | Two NPN transistor outputs, load current 200 mA max., residual voltage 2 V max. (except for voltage drop due to cable extension), Leakage current 1 mA max., load inductance 2.2 H max. *3, Maximum capacity load 1 μF *4 |
|
Output operation mode | Safety output: On when receiving light | |
Input voltage | PNP output | Test input: ON voltage: Vs-3 V to Vs (short circuit current: approx. 3.0 mA) *5 OFF voltage: 0 V to 1/2 Vs or open (short circuit current: approx. 4.0 mA) *5 |
NPN output | Test input: ON voltage: 0 to 3 V (short circuit current: approx. 4.0 mA) OFF voltage: 1/2 Vs to Vs or open (short circuit current: approx. 3.0 mA) *5 |
|
Mutual interference prevention function |
Mutual interference prevention algorithm prevents interference in up to 3 sets. | |
Test function | Self test (at power-ON and at power distribution) External test (emission stop function by test input) |
|
Protection circuit | Output short-circuit protection, and power supply reverse polarity protection | |
Ambient temperature | Operating: -10 to 55°C (non-freezing), Storage: -25 to 70°C | |
Ambient humidity | Operating: 35% to 85% (no condensation), Storage: 35% to 95% RH | |
Operating ambient light intensity |
Incandescent lamp: 3,000 lx max., Sunlight: 10,000 lx max. | |
Insulation resistance | 20 MΩ min. (at 500 VDC) | |
Dielectric strength | 1,000 VAC 50/60 Hz, 1 min | |
Degree of protection | IP65 (IEC 60529) | |
Vibration resistance | Class 3M4 (IEC TR 60721-4-3) Operation limit: 5 to 150 Hz, Multiple amplitude of 7 mm, Acceleration of 1 G, 10 sweeps each in X, Y, and Z directions (no delay at resonant frequencies) |
|
Shock resistance | Class 3M4 (IEC TR 60721-4-3) Operation limit: Acceleration of 15 G, Pulse duration of 6 ms, 100 shocks for each in X, Y, and Z directions (600 shocks in total) |
|
Pollution degree | Pollution degree 3 (IEC 60664-1) | |
Power cable | Connection method: Pull-out type, cable length 3 m Number of wires: Emitter: 5 wires, receiver: 6 wires Cable diameter: Dia. 6 mm Allowable bending radius: R5 mm |
|
Extension cable | 30 m max. *6 | |
Material | Case: Aluminum Cap: ABS resin, PBT Optical cover: PMMA resin (acrylic) Cable: Oil resistant PVC |
|
Net Weight *7 | Weight (g) = (protective height) x 1.59 + 330 | |
Gross Weight *8 | Weight (g) = (protective height) x 2.6 + 800 | |
Accessories | Instruction Manual, Quick Installation Manual (QIM) *9 | |
Applicable standards *10 | IEC 61496-1, EN 61496-1, UL 61496-1, Type 4 ESPE (Electro-Sensitive Protective Equipment) IEC 61496-2, EN 61496-2, UL 61496-2, Type 4 AOPD (Active Opto-electronic Protective Devices) IEC 61508-1 to -3, EN 61508-1 to -3 SIL3 ISO 13849-1: 2015, EN ISO 13849-1: 2015 (PLe/Safety Category 4) UL 508, UL 1998, CAN/CSA C22.2 No.14, CAN/CSA C22.2 No.0.8 |
*1. Do not use the Support Software and Setting Console for F3SJ-A. Operation cannot be guaranteed.
*2. Use of the Spatter Protection Cover causes a 10% maximum sensing distance attenuation.
*3. The load inductance is the maximum value when the safety output frequently repeats ON and OFF. When you use the
safety output at 4 Hz or less, the usable load inductance becomes larger.
*4. These values must be taken into consideration when connecting elements including a capacitive load such as capacitor.
*5. The Vs indicates a voltage value in your environment.
*6. To extend a cable of the F3SJ-E, refer to the User’s Manual (SCHG-733/732).
*7. The net weight is the weight of an emitter and a receiver.
*8. The gross weight is the weight of an emitter, a receiver, included accessories and a package.
*9. Mounting brackets and test rod are sold separately.
*10.Refer to Safety Precautions for information about Legislation and Standards.
Indicator
Emitter
Nameofindicator | Label | ON | Blinking |
---|---|---|---|
Top-beam-state indicator |
TOP | Turns ON when the top beam is receiving light. |
— |
Stable-state indicator |
STB | Turns ON when incidence level is more than 170% of the output ON threshold. |
Blinks when the safety output is turned OFF due to disturbance light or vibration. |
ON/OFF-state indicator |
ON OFF |
Green: Turns ON when safety output is ON. Red: Turns OFF when safety output is OFF. |
Red: Blinks when the F3SJ-E enters a lockout due to a safety output error. |
Lockout indicator | LOCKOUT | Turns ON when the F3SJ-E enters a lockout on the receiver. |
Blinks when the F3SJ-E enters a lockout on the emitter. |
Power indicator | POWER | Turns ON while the power of the emitter is ON. |
Blinks when the F3SJ-E enters a lockout due to power voltage/noise. |
Test indicator | TEST | — | Blinks when external test is being performed. |
Bottom-beam- state indicator |
BTM | Turns ON when the bottom beam is receiving light. |
— |
Receiver
Nameofindicator | Label | ON | Blinking |
---|---|---|---|
Top-beam-state indicator |
TOP | Turns ON when the top beam is receiving light. |
— |
Stable-state indicator |
STB | Turns ON when incidence level is more than 170% of the output ON threshold. |
Blinks when the safety output is turned OFF due to disturbance light or vibration. |
ON/OFF-state indicator |
ON OFF |
Green: Turns ON when safety output is ON. Red: Turns OFF when safety output is OFF. |
Red: Blinks when the F3SJ-E enters a lockout due to a safety output error. |
Lockout indicator | LOCKOUT | Turns ON when the F3SJ-E enters a lockout on the emitter. |
Blinks when the F3SJ-E enters a lockout on the receiver. |
Communication indicator |
COM | Turns ON when communication between emitter and receiver is established. |
Blinks when the F3SJ-E enters lockout due to a communication error between receiver and emitter. |
Configuration indicator |
CFG | — | Blinks when the F3SJ-E enters lockout due to a model type error between receiver and emitter. |
Internal error indicator |
INTERNAL | — | Blinks when the F3SJ-E enters a lockout due to an internal error. |
Bottom-beam- state indicator |
BTM | Turns ON when the bottom beam is receiving light. |
— |
Model | F3SJ-E0185N25, F3SJ-E0225N25, F3SJ-E0305N25, F3SJ-E0385N25, F3SJ-E0465N25, F3SJ-E0545N25, F3SJ-E0545P25, F3SJ-E0625N25, F3SJ-E0705N25, F3SJ-E0785N25, F3SJ-E0865N25, F3SJ-E0865P25, F3SJ-E0945N25, F3SJ-E0945P25, F3SJ-E1025N25, F3SJ-E1025P25, F3SJ-E1105N25, F3SJ-E1105P25 |
---|
Related products
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details