$ 49.50 – $ 84.04
EX-F1 amplifier built-in sensor saves space as there is no need to install a separate amplifier.
Just attach it on a pipe with the tying bands. The position can be easily changed with the release lever even after mounting, so that there is no need to cut the tying bands. |
EX-F1 is very cost-effective.
The operation can be checked at a glance from different directions. |
Either Light-ON or Dark-ON can be selected by a switch. This is useful to check the operation during installation because it forces the output to be turned ON or OFF even without the liquid being inside the pipe.
Type | Amplifier built-in, Pipe-mountable | |
---|---|---|
Model No. | EX-F1 | |
CE marking directive compliance | EMC Directive, RoHS Directive | |
Sensing object | Liquid (Note 2) | |
Applicable pipe diameter | Outer dia. ø6 to ø13 mm ø0.236 to ø0.512 in transparent resin pipe [PFA (Fluorine resin) or equivalently transparent pipe, wall thickness 1 mm 0.039 in ] (Note 3) |
|
Supply voltage / Current consumption | 12 to 24 V DC ± 10 % Ripple P-P 10 % or less / 30 mA or less | |
Output | NPN open-collector transistor – Maximum sink current: 100 mA – Applied voltage: 30 V DC or less (between output and 0 V) – Residual voltage: 1 V or less (at 100 mA sink current) 0.4 V or less (at 16 mA sink current) |
|
Utilization category | DC-12 or DC-13 | |
Output operation | Switchable either Light-ON (Liquid-absent-ON) or Dark-ON (Liquid-present-ON) | |
Short-circuit protection | Incorporated | |
Response time | 2 ms or less | |
Operation indicator | Red LED (lights up when the output is ON) | |
Pollution degree | 3 (Industrial environment) | |
Ambient temperature (Note 4) | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℃ -4 to +158 ℉ | |
Ambient humidity / Ambient illuminance | 35 to 85 % RH, Storage: 35 to 85 % RH / lncandescent light: 3,000 lx or less at the light-receiving face | |
Voltage withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure | |
Insulation resistance | 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure | |
Vibration resistance | 10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each | |
Shock resistance | 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each | |
Emitting element | Infrared LED (modulated) | |
Material | Enclosure: Polycarbonate, Tying band: Nylon, Anti-slip tube: Silicone | |
Cable | 0.1 mm2 3-core cabtyre cable, 1 m 3.281 ft long | |
Cable extension | Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable. | |
Weight | Net weight: 15 g approx., Gross weight: 60 g approx. | |
Accessories | Tying band: 2 pcs., Anti-slip tube: 2 pcs. |
Note 1: | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉. |
---|---|
Note 2: | Unclear or highly viscous liquid may not be detected stably. |
Note 3: | Do not use the sensor with pipes other than the above specified. |
Note 4: | Liquid being detected should also be kept within the rated ambient temperature range. |