$ 347.60
The ER-V Ultra-Compact Ionizer offers a new style in charge removal. It uses high frequency AC in an ultra-compact Ionizer for superior static elimination.
Panasonic Ultra-compact Ionizer ER-V Series Features :
The Panasonic Ultra-compact Ionizer ER-V Series Part Number :
ER-VS02
The discharge needle can be removed from the rear of the main unit, so there is no need to remove the nozzle when replacing the needle. Maintenance is easy even when the ion air outlet is located close to the object.
A “checking function” and an “abnormal discharge monitoring function” are provided to notify the operator when it is time to clean or replace the discharge needle and to prevent discharge problems from occurring. Each function has an LED display to use for checking. The output from each function can also be used to externally monitor the status of the ionizer during operation.
The power supply voltage is 24 V DC, and the power consumed is only 70 mA or less.
In addition, safety is enhanced because no high-voltage cables are required.
The discharge needle does not protrude from the main unit, so it cannot be touched by accident. Furthermore, no leaks can occur when it is brought close to metallic objects.
A full range of functions have been provided with full consideration given to ease of use in the workplace. No separate controller is needed.
A signal from an external device can be used to turn discharge ON and OFF. Sensors can be used to detect the objects so that the ion air is generated only when required
The discharge ON/OFF status can be checked using an LED display. This lets you avoid problems such as when the power is on but no discharge is occurring.
Item | Specifications |
---|---|
CE marking compliant directives | EMC Directive, RoHS Directive |
Charge removal time | 1 sec. or less (plus or minus1,000 V to plus or minus100 V) (Note) A typical sample applied with a supply voltage of 24 V, a distance of 100 mm 3.937 in from the front surface of the air flow outlet and a pressure of 0.25 MPa while the shower nozzle is in use. (Measured on a sample left in the atmosphere at a relative humidity of 65 % RH or less for 24 hours or more.) |
Ion balance | plus or minus10 V or less (Note) A typical sample applied with a supply voltage of 24 V, a distance of 100 mm 3.937 in from the front surface of the air flow outlet and a pressure of 0.25 MPa while the shower nozzle is in use. (Measured on a sample left in the atmosphere at a relative humidity of 65 % RH or less for 24 hours or more.) |
Ozone generation | 0.03 ppm or less (Note) A typical sample applied with a power voltage of 24 V, a distance of 300 mm 11.811 in from the front surface of the air flow outlet and a pressure of 0.25 MPa while the shower nozzle is in use. |
Applicable fluid | Air (dried clean air) (Note) The air is dried (dew point: equivalent of –20 ℃ – 4 ℉) and filtered (mesh-size: equivalent of 0.01 microm 0.0004 mil) air. |
Supplied air flow | 500 liter/min. (ANR) or less (Note) The applicable pressure range depends on the nozzle to be used. |
Air pressure range | 0.05 to 0.7 MPa (Note) The applicable pressure range depends on the nozzle to be used. |
Supply voltage | 24 V DC plus or minus10 % |
Current consumption | 70 mA or less |
Discharge method | High frequency AC method |
Discharge output voltage | 2,000 V approx. |
Check output(CHECK) | NPN open-collector transistor • Maximum sink current: 50 mA • Applied voltage: 30 V DC or less (between check output and 0 V) • Residual voltage: 1 V or less (at 50 mA sink current) |
Check output:Output operation | ON when a dirt or worn etc. of the discharge needle is detected for 1.5 sec. or more continuously, OFF when operation is normal (Note) When confirming the check output, carry out discharge for 2 sec. or more. |
Check output:Short-circuit protection | Incorporated |
Error output | NPN open-collector transistor • Maximum sink current: 50 mA • Applied voltage: 30 V DC or less (between error output and 0 V) • Residual voltage: 1 V or less (at 50 mA sink current) |
Error output:Output operation | OFF when abnormal discharge is detected, ON when operation is normal |
Error output:Short-circuit protection | Incorporated |
Discharge halt input (DSC OFF) | Short-circuit to 0 V: Discharge halt, Open: Discharge allowed (operation start) (Note: ”DSC” is an abbreviated name of ”DISCHARGE”.) |
Reset input (RESET) | When abnormal discharge is detected, discharge is halted due to an error. Reset the discharge halt by briefly shorting the power supply’s 0 V line. |
Indicators:Power (POWER) | Green LED (lights up when the power is ON) |
Indicators:Discharge (DSC) | Green LED (lights up when discharging) (Note: ”DSC” is an abbreviated name of ”DISCHARGE”.) |
Indicators:Check (CHECK) | Orange LED (lights up when the discharge needle is worn or dirty, etc.) (Note) When confirming the check output, carry out discharge for 2 sec. or more. |
Indicators:Error (ERROR) | Red LED (lights up when abnormal discharge is detected) |
Ambient temperature | 0 to +55 ℃ +32 to +131 ℉ (No dew condensation allowed) |
Ambient humidity | 35 to 65 % RH |
Vibration resistance | 10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each |
Cable | Cable with a connector, 0.5 m 1.640 ft long |
Material | Enclosure: PPS, Cover: Stainless steel, Discharge needle: Tungsten |
Weight | Net weight: 120 g approx. |
Accessories | Connector for wiring: 1 set [Manufactured by Molex: Housing (5557-08R), Terminal (5556TL)] |