ER-F Series, Panasonic Fan Type Ionizer

USD $ 227.01USD $ 232.05

SKU: N/A

With a compact size of 150 x 166 x 62mm and a fan of 120mm in diameter, the ER-F Fan Type Ionizer belongs to the leading class of compact Fan Type Ionizers. The system employs a high-frequency AC method and boasts a +/-2kV discharge output voltage that discharges electrostatic contaminated objects quickly and safely. Louvers for long distance and wide area applications are shipped with the Ionizers. Standard fan types for faster charge removal times and low-volume types for discharging small parts or film are available.

Panasonic Fan Type Ionizer ER-F Series Features :

  • Straight And Angle Louvers Provided With The Ionizer
  • Easy Maintenance Of Discharge Needle
  • Safe Design
  • 24 V DC
  • No External, Compressed Air Necessary

For the Part Number not in our attribute selection, please contact us directly: sales@inosaki.com

The Panasonic Fan Type Ionizer ER-F Series Part Number :
ER-F12A,ER-F12SA

Data Sheet   |   Selection Guide

Two exchangeable louvers to suit your needs

Just simply replace the louver to change configuration between long distance and wide area ionization.

The two louvers come with the ionizer main body.

 

 

Equipped with discharge needle fouling detection function

Additionally equipped with discharge needle fouling detection function. When discharge becomes weak due to needle fouling, the DSC indicator will flash for notification

Remove the louver for effortless maintenance

Because the discharge needle unit is attached to the louver, exchange or maintenance of the needles is made easy without touching the main unit . A safe design where once the louver is removed, the high-voltage circuit and the fan will halt.

 

 

 

 

 

ORDER GUIDE

Type Charge removal time (±1,000 V   ±100 V) Ion balance Model No.
Standard fan type 1 sec. approx. (Note 1) ±10 V or less

(Note 2)

ER-F12A
Low-volume fan type 1.5 sec. approx. (Note 1) ER-F12SA

Notes: 

1) Typical value at 200 mm 7.874 in from directly in front of air outlet, fan speed MAX, straight louver, with no filter installed.

2) Typical value at 300 mm 11.811 in from directly in front of air outlet, fan speed MAX, straight louver, with no filter installed.

 

Specifications

Item Specifications
CE marking compliant directives EMC Directive, RoHS Directive
Charge removal time 1.5 sec. approx.(±1,000 V → ±100 V)
(Note): Typical value at 200 mm 7.874in from directly in front of air outlet, fan speed MAX, straight louver, with no filter installed.
Ion balance ±10 V or less
(Note): Typical value at 300 mm 11.811in from directly in front of air outlet, fan speed MAX, straight louver, with no filter installed.
Supply voltage 24 V DC ±10%
Current consumption 400 mA or less
Discharge method High-frequency AC method
Discharge output voltage ± 2 kV approx.
Main functions Error output, Discharge halt input
Indicators Discharge error (Red), Fan error (Red), Power (Green), Discharge (Green)
Ozone generation 0.04 ppm or less
(Note): Typical value at 200 mm 7.874in from directly in front of air outlet, fan speed MAX, straight louver, with no filter installed.
Ambient temperature 0℃ to +50℃ +32℉ to +122℉ (No dew condensation allowed),
Storage : -10℃ to +65℃ +14℉ to +149℉
Ambient humidity 35% RH to 65% RH (No dew condensation allowed),
Storage : 35% RH to 65% RH
Grounding method C (capacitor) grounding
Material Enclosure : ABS, Louver : ABS, Discharge needle unit : PBT, Discharge needle : Tungsten, Bracket : SPHC
Weight New weight : 790 g approx.
Accessories Straight louver : 1 pc. (Note), Angle louver : 1 pc., Caution label : 1 set, Rubber cushion : 1 pc.
(Note): The discharge needle unit is loaded on the straight louver before shipment.
Remark If not specified, the ambient temperature for measurement is +20℃ +68℉.