Omron produce industrial sensors range such as fiber sensors, photoelectric sensors, displacement sensors/ measurement sensors, proximity sensors, photomicro sensors and rotary encodes.
Features
• Operation mode selector allows modes to be switched easily.
• Sensitivity selector is suitable for any 6- to 13-mm-diameter transparent or semi-transparent pipe with a wall thickness of 1 mm.
• Uses a clean (with no powder parting agent) cable.
• Operating voltage range: 12 to 24 VDC
Sensing method | Output type | Output configuration | Cable length | Model |
---|---|---|---|---|
Through-beam type | NPN output | Dark-ON or Light-ON (selectable) |
1 m | EE-SPX613 1M |
Models | EE-SPX613 | |
Applicable pipe | Any 6- to 13-mm-diameter pipe with a wall thickness of 1 mm that is made of FEP or any other material as transparent as FEP. | |
Sensing object | Liquids in pipes (High-viscosity liquids or liquids with floating materials may not be detected.) | |
Light source | GaAs infrared LED with a peak wavelength of 940 nm | |
Indicator | Light indicator GaP (Red LED: Peak wavelength of 700 nm) | |
Supply voltage | 12 to 24 VDC ±10%, ripple (p-p): 5% max. | |
Current consumption | Average: 30 mA max., Peak: 80 mA max. | |
Control output | NPN open collector: | |
Load power supply voltage: 5 to 24 VDC | ||
Load current: 100 mA max. | ||
OFF current: 0.5 mA max. | ||
100 mA load current with a residual voltage of 0.8 V max. | ||
40 mA load current with a residual voltage of 0.4 V max. | ||
Ambient illumination | 3,000 lx max. with incandescent light or sunlight on the surface of the receiver | |
Ambient temperature | Operating: – 10 to +55 ° C | |
range | Storage: – 25 to +65 ° C (with no icing or condensation) | |
Ambient humidity | Operating: 5% to 85% | |
range | Storage: 5% to 95% (with no condensation) | |
Vibration resistance | Destruction: 10 to 500 Hz, 1.0-mm single amplitude or 150 m/s2 in X, Y, and Z directions | |
3 times and for 11 min each | ||
Shock resistance | Destruction: 500 m/s2 for 3 times each in X, Y, and Z directions | |
Degree of protection | IEC 60529 IP50 | |
Connecting method | Pre-wired (Standard length: 1 m) | |
Weight (packed state) | Approx. 55 g | |
Material | Case | Polycarbonate |
Cover | ||
Accessories | Support belt (2), slip protection tube (2), Instruction Manual |