$ 1,591.60
Manufacturer Part Number: MOXA EDS-2016-ML-SS-SC-T
The MOXA EDS-2016-ML-SS-SC-T is an exceptional Unmanaged Industrial Ethernet Switch that excels in providing reliable network connectivity for industrial applications. Designed to endure challenging environments, this robust switch is a prime choice for industries seeking dependable and straightforward networking solutions without complex setup requirements.
Key Features:
Benefits:
Applications:
The MOXA EDS-2016-ML-SS-SC-T Unmanaged Industrial Ethernet Switch stands as a testament to MOXA’s commitment to delivering robust and efficient networking solutions that cater to the demanding needs of industrial applications.
| Ethernet Interface | 10/100BaseT(X) Ports (RJ45 connector) | 14 | 
| 100BaseFX Ports (multi-mode SC connector) | 2 | |
| 100BaseFX Ports (single-mode SC connector) | 2 | |
| Standards | IEEE 802.3 for 10BaseT IEEE 802.3u for 100BaseT(X) IEEE 802.3x for flow control IEEE 802.1p for Class of Service  | 
|
| Optical Fiber | Refer table 2 | |
| DIP Switch Configuration | Ethernet Interface | Quality of Service (QoS) Broadcast storm protection Port break alarm  | 
| Input/Output Interface | Alarm Contact Channels | Relay output with current carrying capacity of 1 A @ 24 VDC | 
| Switch Properties | MAC Table Size | 8 K | 
| Packet Buffer Size | 2 Mbits | |
| Processing Type | Store and Forward | |
| Power Parameters | Connection | 1 removable 6-contact terminal block(s) | 
| Input Voltage | 12/24/48 VDC Redundant dual inputs  | 
|
| Operating Voltage | 9.6 to 60 VDC | |
| Overload Current Protection | Supported | |
| Reverse Polarity Protection | Supported | |
| Physical Characteristics | Housing | Metal | 
| IP Rating | IP30 | |
| Dimensions | 58 x 135 x 95 mm (2.28 x 5.31 x 3.74 in) | |
| Weight | 648 g (1.43 lb) | |
| Installation | DIN-rail mounting Wall mounting (with optional kit)  | 
|
| Environmental Limits | Operating Temperature | -40 to 75°C (-40 to 167°F) | 
| Storage Temperature | -40 to 85°C (-40 to 185°F) | |
| Ambient Relative Humidity | 5 to 95% (non-condensing) | |
| Standards and Certifications | Safety | UL 61010-2-201 EN 62368-1(LVD)  | 
| EMC | EN 55032/35 EN 61000-6-2/-6-4  | 
|
| EMI | CISPR 32, FCC Part 15B Class A | |
| EMS | IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV IEC 61000-4-3 RS: 80 MHz to 1 MHz: 20 V/m IEC 61000-4-4 EFT: Power: 2 kV; Signal: 2 kV IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV IEC 61000-4-6 CS: 10 V IEC 61000-4-8 PFMF  | 
|
| Hazardous Locations | Class I Division 2 ATEX IECEx  | 
|
| Railway | EN 50121-4 | |
| Traffic Control | NEMA TS2 | |
| Vibration | IEC 60068-2-6 | |
| Shock | IEC 60068-2-27 | |
| Freefall | IEC 60068-2-32 | |
| Maritime | DNV LR ABS NK  | 
|
| MTBF | Time | 2,070,826 hrs | 
| Standards | Telcordia (Bellcore), GB | |
| Warranty | Warranty Period | 5 years | 
| Details | See www.moxa.com/warranty | 
| 100BaseFX | |||||
| Multi-Mode | Single-Mode (40 km) | Single-Mode (80 km) | |||
| Fiber Cable Type | OM1 | 50/125 µm | G.652 | G.652 | |
| 800 MHz x km | |||||
| Typical Distance | 4 km | 5 km | 40 km | 80 km | |
| Wavelength | Typical (nm) | 1300 | 1310 | 1550 | |
| TX Range (nm) | 1260 to 1360 | 1280 to 1340 | 1530 to 1570 | ||
| RX Range (nm) | 1100 to 1600 | 1100 to 1600 | 1100 to 1600 | ||
| Optical Power | TX Range (dBm) | -10 to -20 | 0 to -5 | 0 to -5 | |
| RX Range (dBm) | -3 to -32 | -3 to -34 | -3 to -34 | ||
| Link Budget (dB) | 12 | 29 | 29 | ||
| Dispersion Penalty (dB) | 3 | 1 | 1 | ||
Note: When connecting a single-mode fiber transceiver, we recommend using an attenuator to prevent damage caused by excessive optical power.
Note: Compute the “typical distance” of a specific fiber transceiver as follows: Link budget (dB) > dispersion penalty (dB) + total link loss (dB).