EDS-2016-ML-SS-SC-T – MOXA Unmanaged Switches
$ 1,522.40
Manufacturer Part Number: MOXA EDS-2016-ML-SS-SC-T
OEM Spec Ref
The MOXA EDS-2016-ML-SS-SC-T is an exceptional Unmanaged Industrial Ethernet Switch that excels in providing reliable network connectivity for industrial applications. Designed to endure challenging environments, this robust switch is a prime choice for industries seeking dependable and straightforward networking solutions without complex setup requirements.
Key Features:
- Plug-and-Play Operation: Ensures easy installation and operation with no software configuration required, facilitating immediate network expansion and connectivity.
- Industrial Durability: Crafted with a rugged metal casing, the EDS-2016-ML-SS-SC-T is designed to withstand industrial environments, including vibrations, shocks, and extreme temperatures.
- High Port Density: Equipped with 16 Fast Ethernet ports, it offers ample connectivity options for multiple devices, enhancing network flexibility.
- Redundant Power Inputs: Dual power inputs provide power redundancy, minimizing the risk of downtime due to power failures, crucial for critical industrial applications.
- Traffic Prioritization: Supports IEEE 802.1p QoS for prioritizing network traffic, ensuring that critical data is transmitted efficiently and reliably.
Benefits:
- Increased Network Reliability: By providing stable and uninterrupted connectivity, it helps maintain the operational continuity of industrial networks.
- Cost-Efficiency: As an unmanaged switch, it reduces setup and maintenance costs by eliminating the need for managed network solutions.
- Scalability: Allows for simple network expansion as the demand for more devices and connectivity increases within industrial settings.
- Enhanced Safety: The robust construction and reliable performance contribute to safer industrial operations by reducing network-related failures.
Applications:
- Industrial Automation: Integrates seamlessly into automation systems, providing a reliable network backbone for controllers, sensors, and machinery.
- Surveillance Systems: Ideal for supporting network traffic from surveillance cameras and security systems in harsh environments.
- Building Management Systems: Ensures consistent network performance for managing various building operations such as HVAC and lighting controls.
- Transportation and Infrastructure: Suitable for deployment in transportation systems where constant and reliable communication is essential.
The MOXA EDS-2016-ML-SS-SC-T Unmanaged Industrial Ethernet Switch stands as a testament to MOXA’s commitment to delivering robust and efficient networking solutions that cater to the demanding needs of industrial applications.
Specification
Ethernet Interface | 10/100BaseT(X) Ports (RJ45 connector) | 14 |
100BaseFX Ports (multi-mode SC connector) | 2 | |
100BaseFX Ports (single-mode SC connector) | 2 | |
Standards | IEEE 802.3 for 10BaseT IEEE 802.3u for 100BaseT(X) IEEE 802.3x for flow control IEEE 802.1p for Class of Service |
|
Optical Fiber | Refer table 2 | |
DIP Switch Configuration | Ethernet Interface | Quality of Service (QoS) Broadcast storm protection Port break alarm |
Input/Output Interface | Alarm Contact Channels | Relay output with current carrying capacity of 1 A @ 24 VDC |
Switch Properties | MAC Table Size | 8 K |
Packet Buffer Size | 2 Mbits | |
Processing Type | Store and Forward | |
Power Parameters | Connection | 1 removable 6-contact terminal block(s) |
Input Voltage | 12/24/48 VDC Redundant dual inputs |
|
Operating Voltage | 9.6 to 60 VDC | |
Overload Current Protection | Supported | |
Reverse Polarity Protection | Supported | |
Physical Characteristics | Housing | Metal |
IP Rating | IP30 | |
Dimensions | 58 x 135 x 95 mm (2.28 x 5.31 x 3.74 in) | |
Weight | 648 g (1.43 lb) | |
Installation | DIN-rail mounting Wall mounting (with optional kit) |
|
Environmental Limits | Operating Temperature | -40 to 75°C (-40 to 167°F) |
Storage Temperature | -40 to 85°C (-40 to 185°F) | |
Ambient Relative Humidity | 5 to 95% (non-condensing) | |
Standards and Certifications | Safety | UL 61010-2-201 EN 62368-1(LVD) |
EMC | EN 55032/35 EN 61000-6-2/-6-4 |
|
EMI | CISPR 32, FCC Part 15B Class A | |
EMS | IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV IEC 61000-4-3 RS: 80 MHz to 1 MHz: 20 V/m IEC 61000-4-4 EFT: Power: 2 kV; Signal: 2 kV IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV IEC 61000-4-6 CS: 10 V IEC 61000-4-8 PFMF |
|
Hazardous Locations | Class I Division 2 ATEX IECEx |
|
Railway | EN 50121-4 | |
Traffic Control | NEMA TS2 | |
Vibration | IEC 60068-2-6 | |
Shock | IEC 60068-2-27 | |
Freefall | IEC 60068-2-32 | |
Maritime | DNV LR ABS NK |
|
MTBF | Time | 2,070,826 hrs |
Standards | Telcordia (Bellcore), GB | |
Warranty | Warranty Period | 5 years |
Details | See www.moxa.com/warranty |
Optical Fiber
100BaseFX | |||||
Multi-Mode | Single-Mode (40 km) | Single-Mode (80 km) | |||
Fiber Cable Type | OM1 | 50/125 µm | G.652 | G.652 | |
800 MHz x km | |||||
Typical Distance | 4 km | 5 km | 40 km | 80 km | |
Wavelength | Typical (nm) | 1300 | 1310 | 1550 | |
TX Range (nm) | 1260 to 1360 | 1280 to 1340 | 1530 to 1570 | ||
RX Range (nm) | 1100 to 1600 | 1100 to 1600 | 1100 to 1600 | ||
Optical Power | TX Range (dBm) | -10 to -20 | 0 to -5 | 0 to -5 | |
RX Range (dBm) | -3 to -32 | -3 to -34 | -3 to -34 | ||
Link Budget (dB) | 12 | 29 | 29 | ||
Dispersion Penalty (dB) | 3 | 1 | 1 |
Note: When connecting a single-mode fiber transceiver, we recommend using an attenuator to prevent damage caused by excessive optical power.
Note: Compute the “typical distance” of a specific fiber transceiver as follows: Link budget (dB) > dispersion penalty (dB) + total link loss (dB).
Weight | 0.648 kg |
---|---|
Dimensions | 5.8 × 13.5 × 9.5 cm |