Easy Pact EZD – EZD100M – Molded Case Circuit Breakers – Schneider Circuit Breakers

$ 62.04

SKU: EZD100M3040N

EZD100M3040N of EZD series is a class A class 3 fixed molded case circuit breaker, which meets the requirements of IEC60947&GB14048 standard, shell frame current 100A@40°C, rated working voltage 500V@50/60Hz, rated insulation voltage 690V, 30kA@415V limit breaking capacity, product with isolation marking and the position of the operating handle can reliably indicate the position of the internal contacts. The maximum expected mechanical life of the product is 10000 times and the electrical life is 4000 times@440V&In, all wiring poles are overload and short circuit protection, equipped with a thermal magnetic release with a rated current of 40A, according to different needs can be selected with different electrical accessories and connection accessories, the circuit breaker and auxiliary device meet the IEC60068-2-30 requirements of 45°C and 95% relative humidity requirements, According to the actual needs, the bottom plate or guide rail can be installed in the switch cabinet and provide class II panel and all internal wiring insulation and the highest IP54 protection level, the materials used in the product are made of non-polluting materials that meet the requirements of ISO14001 standard and can be recycled.

 

Specifications

Key information
Product family EZD
Product type Breakers
Short name of the product EZD100M
Circuit breaker applications Distribution protection
Number of poles 3P
Protection pole description .3D
Supplemental Information
Rated current [In] 40 A in… Up to 40 °C
Circuit breaker model M
Grid type AC
Grid frequency 50/60 Hz
Control type Handle
Installation type Fixed
Installation method Backplane installation
Connection method – upper end Front connection
Connection method – lower end Front connection
Rated insulation voltage [UI] 690 V TM-D compliant
Rated impulse withstand voltage [UIMP] 6 kV is TM-D compliant
Rated operating voltage [UE] 500 V AC 50/60 Hz TM-D compliant
Breaking ability 10 kA Icu in… On 500 V AC 50/60 Hz compliant TM-D
20 kA Icu in… On 440 V AC 50/60 Hz compliant TM-D
65 kA Icu in… On 220/230 V AC 50/60 Hz compliant TM-D
35 kA Icu in… On 380/400 V AC 50/60 Hz compliant TM-D
30 kA ICCU in… Up to 415 V AC 50/60 Hz TM-D compliant
Use categories AC class
Using Breaking Capability [ICS] 30 kA in… On 220/230 V AC 50/60 Hz conforms to TM-D
17 kA in… On 380/400 V AC 50/60 Hz conforms to TM-D
7 kA in… On 415 V AC 50/60 Hz conforms to TM-D
5 kA in… On 440 V AC 50/60 Hz conforms to TM-D
3 kA in… Up 500 V AC 50/60 Hz TM-D compliant
Mechanical life 8500 times
Electrical life 4000 times 440 V In TM-D compliant
Phase spacing 25 mm
Trip name TM-D
Trip type Thermal-magnetic
Trip rating 40 A in… Up to 40 °C
Protection type Short circuit protection (magnetic protection) overload protection (thermal protection)
Long delay current tuning type Fixed
Long delay current setting [IR] 1 In
Instantaneous protection current tuning type Fixed
height 130 mm
width 75 mm
depth 60 mm
Product weight 0.78 kg
Model EZD100
environment
Compliance with standards IEC 60947-2
Pollution level 3 Complies with IEC 60947-1
Operating temperature -25… 70 °C
Storage ambient temperature -50… 85 °C
Packaging unit
Unit Type of Package 1 PCE
Package 1 Height 9.5 cm
Package 1 Length 13.8 cm
Weight 0.78 kg
Dimensions 6.0 × 7.5 × 13.0 cm