Easy Pact EZD – EZD100M – Molded Case Circuit Breakers – Schneider Circuit Breakers
$ 62.04
EZD100M3040N of EZD series is a class A class 3 fixed molded case circuit breaker, which meets the requirements of IEC60947&GB14048 standard, shell frame current 100A@40°C, rated working voltage 500V@50/60Hz, rated insulation voltage 690V, 30kA@415V limit breaking capacity, product with isolation marking and the position of the operating handle can reliably indicate the position of the internal contacts. The maximum expected mechanical life of the product is 10000 times and the electrical life is 4000 times@440V&In, all wiring poles are overload and short circuit protection, equipped with a thermal magnetic release with a rated current of 40A, according to different needs can be selected with different electrical accessories and connection accessories, the circuit breaker and auxiliary device meet the IEC60068-2-30 requirements of 45°C and 95% relative humidity requirements, According to the actual needs, the bottom plate or guide rail can be installed in the switch cabinet and provide class II panel and all internal wiring insulation and the highest IP54 protection level, the materials used in the product are made of non-polluting materials that meet the requirements of ISO14001 standard and can be recycled.
Specifications
Key information | |
Product family | EZD |
Product type | Breakers |
Short name of the product | EZD100M |
Circuit breaker applications | Distribution protection |
Number of poles | 3P |
Protection pole description | .3D |
Supplemental Information | |
Rated current [In] | 40 A in… Up to 40 °C |
Circuit breaker model | M |
Grid type | AC |
Grid frequency | 50/60 Hz |
Control type | Handle |
Installation type | Fixed |
Installation method | Backplane installation |
Connection method – upper end | Front connection |
Connection method – lower end | Front connection |
Rated insulation voltage [UI] | 690 V TM-D compliant |
Rated impulse withstand voltage [UIMP] | 6 kV is TM-D compliant |
Rated operating voltage [UE] | 500 V AC 50/60 Hz TM-D compliant |
Breaking ability | 10 kA Icu in… On 500 V AC 50/60 Hz compliant TM-D |
20 kA Icu in… On 440 V AC 50/60 Hz compliant TM-D | |
65 kA Icu in… On 220/230 V AC 50/60 Hz compliant TM-D | |
35 kA Icu in… On 380/400 V AC 50/60 Hz compliant TM-D | |
30 kA ICCU in… Up to 415 V AC 50/60 Hz TM-D compliant | |
Use categories | AC class |
Using Breaking Capability [ICS] | 30 kA in… On 220/230 V AC 50/60 Hz conforms to TM-D |
17 kA in… On 380/400 V AC 50/60 Hz conforms to TM-D | |
7 kA in… On 415 V AC 50/60 Hz conforms to TM-D | |
5 kA in… On 440 V AC 50/60 Hz conforms to TM-D | |
3 kA in… Up 500 V AC 50/60 Hz TM-D compliant | |
Mechanical life | 8500 times |
Electrical life | 4000 times 440 V In TM-D compliant |
Phase spacing | 25 mm |
Trip name | TM-D |
Trip type | Thermal-magnetic |
Trip rating | 40 A in… Up to 40 °C |
Protection type | Short circuit protection (magnetic protection) overload protection (thermal protection) |
Long delay current tuning type | Fixed |
Long delay current setting [IR] | 1 In |
Instantaneous protection current tuning type | Fixed |
height | 130 mm |
width | 75 mm |
depth | 60 mm |
Product weight | 0.78 kg |
Model | EZD100 |
environment | |
Compliance with standards | IEC 60947-2 |
Pollution level | 3 Complies with IEC 60947-1 |
Operating temperature | -25… 70 °C |
Storage ambient temperature | -50… 85 °C |
Packaging unit | |
Unit Type of Package 1 | PCE |
Package 1 Height | 9.5 cm |
Package 1 Length | 13.8 cm |
Weight | 0.78 kg |
---|---|
Dimensions | 6.0 × 7.5 × 13.0 cm |