Specifications
Main | |
Part Number | LC1E400M7N |
Product Series | Compact |
product type | Contactor |
product short name | LC1E |
Application field of contactor | Applied to non-inductive or micro-inductive loads, and |
resistance furnaces to AC loads with a power factor greater than or equal to 0.95 | |
use category | AC-3AC |
-1 | |
number of poles | 3P |
Rated working voltage [Ue] | Power circuit: <= 690 V AC 50/60 Hz |
Rated operating current [Ie] | 400 A 55 °C) at <= 440 V AC AC-3 for power circuits |
500 A 40 °C) at <= 440 V AC AC-1 for power circuits | |
[Uc] control circuit voltage | 230V AC 50/60Hz |
Additional information | |
Motor power (kW) | 110 kW at 220/230 V AC 50/60 Hz (AC-3) |
200 kW at 380/400 V AC 50/60 Hz (AC-3) | |
220 kW at 415/440 V AC 50/ 60 Hz (AC-3) | |
250 kW at 415/440 V AC 50/60 Hz (AC-3) | |
257 kW at 500 V AC 50/60 Hz (AC-3) | |
280 kW at 660/ 690 V AC 50/60 Hz (AC-3) | |
Loop contact type | 3 NO |
Conventional thermal current [Ith] | 500 A at <40 °C for power circuits |
Rated making capacity [Irms] | 4000 A at 440 V AC for power circuits conforming to IEC 60947-4-1 |
Rated breaking capacity | 3200 A at 440 V for power circuits conforming to IEC 60947 |
Rated short-time withstand current [Icw] | 3600 A at <40 °C – 10 s for power circuits |
Fuses for use with relays | 10 A gG at <= 690 V for type 1 suitable control circuits conforming to IEC 60947-5-1 |
630 A gG at <= 690 V for type 1 suitable power circuits | |
average impedance | 0.26 mΩ – Ith 500 A 50 Hz for power circuits |
power consumption per pole | 42W AC-3 |
65W AC-1 | |
Rated insulation voltage [Ui] | 690 V conforming to IEC 60947-4-1 |
Overvoltage category | III |
pollution level | 3 |
Rated impulse withstand voltage [Uimp] | 8 kV coil not connected to power circuit conforming to IEC 60947 |
Mechanical life | 4000000 times |
Electrical life | 250000 times AC-1 |
600000 times AC-3 | |
Control loop characteristics | AC at 50/60 Hz standard |
Control voltage limit | 0.85…1.1 Uc 55 °C Run 50/60 Hz |
0.35…0.5 Uc 55 °C Release 50/60 Hz | |
(~50Hz pickup) power consumption (VA) | 1075 VA 50 Hz 0.9 20 °C) |
1075 VA 60 Hz 0.9 20 °C) | |
(~50Hz hold) power consumption (VA) | 15 VA 50 Hz 0.9 20 °C) |
15 VA 60 Hz 0.9 20 °C) | |
heat dissipation | 14 W for control circuits |
action time | 100…170 ms on opening |
40…75 ms off | |
operating frequency | 2400 cycles/h at <55 °C |
Wiring capacity | Control circuit: Bolt fastening1 1…4 mm² Cable selection: Flexible cord without wire terminals |
Control circuit: Bolt fastening2 1…4 mm² Cable selection: Flexible cord without wire terminal | |
Control circuit: Bolt fastening 1 1…4 mm² cable option: flexible cable with cable terminals | |
control circuit: screw fastened2 1…2.5 mm² cable option: flexible cable with cable terminal | |
control circuit: screw cable option1 1…4 mm² cable option : Solid without wire terminals | |
Control circuit: Bolt fastening2 1…4 mm² Cable selection: Solid without wire terminals | |
Power circuit: Cable with lug2 Lug outer diameter Ø: 150 mm | |
Power circuit: Terminal 2 Busbar cross-section: 30 x 5 mm | |
Tightening torque | Control circuit: 1.2 Nm |
Power circuit: 35 Nm | |
Auxiliary contact type | Does not contain |
Minimum switching voltage | 17 V for control circuits |
Minimum switching current [Imin] | 5 mA for control loop |
Insulation resistance | > 10 MΩ for control loops |
non-overlapping time | 1.5 ms power-on to ensure NC and NO contact |
1.5 ms power-off to ensure NC and NO contact | |
installation method | Chassis mount |
environment | |
standard | IEC 60947-4-1 |
GB 14048.4 | |
certified product | CCC |
IP protection class | IP00 conforming to IEC 60529 |
Protective measures | TH (pollution degree 3) conforming to IEC 60068 |
ambient air temperature | -20…70 °C (allowed at Uc) |
5…55 °C operation | |
-60…80 °C storage | |
working altitude | 3000 m None |
Fire resistance and abnormal high temperature resistance | 850 °C conforming to IEC 60695-2-1 |
Shock and vibration resistance | Shock resistance with contacts closed (15 gn (11ms)) |
shock resistance with contacts open (1.5 gn (5…300 Hz)) | |
shock resistance with contacts open (6 gn (11ms)) | |
shock resistance with contacts closed (5 gn (5…300 Hz)) | |
high | 375 mm |
width | 213 mm |
depth | 219 mm |
Product Weight | 9.1kg |
packaging unit | |
Unit Type of Package 1 | PCE |
Number of Units in Package 1 | 1 |
Package 1 Height | 26.0cm |
Package 1 Width | 25.0cm |
Package 1 Length | 30.0cm |
Package 1 Weight | 9450.0 g |
Unit Type of Package 2 | P06 |
Number of Units in Package 2 | 10 |
Package 2 Height | 67.0cm |
Package 2 Width | 60.0cm |
Package 2 Length | 80.0cm |
Package 2 Weight | 104.5 kg |
contract warranty | |
Warranty | 18 months |
Weight | 9.1 kg |
---|---|
Dimensions | 21.9 × 21.3 × 37.5 cm |
Related products
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details