$ 23.10 – $ 27.28
Product number | MGNEA9C45C1030CA | MGNEA9C45C1630CA | MGNEA9C45C2530CA |
Circuit breaker applications | Distribution protection | Distribution protection | Distribution protection |
Product family | Easy 9 | Easy 9 | Easy 9 |
Short name of the product | EA9C45 | EA9C45 | EA9C45 |
Product type | Residual current action protects the circuit breaker | Residual current action protects the circuit breaker | Residual current action protects the circuit breaker |
Number of poles | 1P + N | 1P + N | 1P + N |
Rated current [In] | 10:00 AM | 16 A | 25 A |
Trip curve | C | C | C |
Residual current sensitivity [IΔn] | 30 mA | 30 mA | 30 mA |
Supplemental Information | |||
Rated operating voltage [UE] | 230 V | 230 V | 230 V |
Network type | AC | AC | AC |
Network frequency | 50 Hz | 50 Hz | 50 Hz |
Trip type | Thermal-magnetic | Thermal-magnetic | Thermal-magnetic |
Magnetic trip restrictions | 5…10 x In | 5…10 x In | 5…10 x In |
Breaking ability | 4.5 kA Icn | 4.5 kA Icn | 4.5 kA Icn |
Leakage current protection level | Category A | Category A | Category A |
Residual current action function technology | The action function is related to the supply voltage | The action function is related to the supply voltage | The action function is related to the supply voltage |
Isolation function | Apply | Apply | Apply |
Control type | Handle | Handle | Handle |
Local signal indication | On/off indication | On/off indication | On/off indication |
Contact position indication | Yes | Yes | Yes |
Leakage current protection | Integrated leakage protection | Integrated leakage protection | Integrated leakage protection |
Mechanical life | 20000 times | 20000 times | 20000 times |
Electrical life | 20000 times 10 A | 20000 times 16 A | 10000 times 25 A |
Installation type | The locking clip is locked | The locking clip is locked | The locking clip is locked |
Installation method | DIN rail mounting | DIN rail mounting | DIN rail mounting |
Wiring capability | M4.2 terminals (upper or lower wiring) – < = 16 mm² | M4.2 terminals (upper or lower wiring) – < = 16 mm² | M4.2 terminals (upper or lower wiring) – < = 16 mm² |
Tightening torque | 2.5 N.m upper or lower wiring | 2.5 N.m upper or lower wiring | 2.5 N.m upper or lower wiring |
Width (multiple of 9mm) | 4 | 4 | 4 |
height | 77 mm | 77 mm | 77 mm |
width | 35.45 mm – 0.33…0.48 mm | 35.45 mm – 0.33…0.48 mm | 35.45 mm – 0.33…0.48 mm |
depth | 75.5 mm | 75.5 mm | 75.5 mm |
environment | |||
Compliance with standards | IEC 61009 | IEC 61009 | IEC 61009 |
GB 16917 | GB 16917 | GB 16917 | |
Product certification | CCC | CCC | CCC |
Operating temperature | -25… 55 °C | -25… 55 °C | -25… 55 °C |
Storage ambient temperature | -40… 80 °C | -40… 80 °C | -40… 80 °C |
Packaging unit | |||
Unit Type of Package 1 | PCE | PCE | PCE |
Number of Units in Package 1 | 1 | 1 | 1 |
Package 1 Height | 7.6 cm | 7.6 cm | 7.6 cm |
Package 1 Width | 3.6 cm | 3.6 cm | 3.6 cm |
Package 1 Length | 7.7 cm | 7.7 cm | 7.7 cm |
Package 1 Weight | 203 g | 203 g | 203 g |
Unit Type of Package 2 | BB1 | BB1 | BB1 |
Number of Units in Package 2 | 6 | 6 | 6 |
Package 2 Height | 8.4 cm | 8.4 cm | 8.4 cm |
Package 2 Width | 9.2 cm | 9.2 cm | 9.2 cm |
Package 2 Length | 22 cm | 22 cm | 22 cm |
Package 2 Weight | 1.242 kg | 1.242 kg | 1.242 kg |
Unit Type of Package 3 | CAR | CAR | CAR |
Number of Units in Package 3 | 48 | 48 | 48 |
Package 3 Height | 20 cm | 20 cm | 20 cm |
Package 3 Width | 27.8 cm | 27.8 cm | 27.8 cm |
Package 3 Length | 37.6 cm | 37.6 cm | 37.6 cm |
Package 3 Weight | 9.841 kg | 9.841 kg | 10 kg |
Contract warranty | |||
Warranty | 18 months | 18 months | 18 months |
Product number | MGNEA9C45C2530CA | MGNEA9C45C3230CA | MGNEA9C45C4030CA |
Circuit breaker applications | Distribution protection | Distribution protection | Distribution protection |
Product family | Easy 9 | Easy 9 | Easy 9 |
Short name of the product | EA9C45 | EA9C45 | EA9C45 |
Product type | Residual current action protects the circuit breaker | Residual current action protects the circuit breaker | Residual current action protects the circuit breaker |
Number of poles | 1P + N | 1P + N | 1P + N |
Rated current [In] | 25 A | 32 A | 40 A |
Trip curve | C | C | C |
Residual current sensitivity [IΔn] | 30 mA | 30 mA | 30 mA |
Supplemental Information | |||
Rated operating voltage [UE] | 230 V | 230 V | 230 V |
Network type | AC | AC | AC |
Network frequency | 50 Hz | 50 Hz | 50 Hz |
Trip type | Thermal-magnetic | Thermal-magnetic | Thermal-magnetic |
Magnetic trip restrictions | 5…10 x In | 5…10 x In | 5…10 x In |
Breaking ability | 4.5 kA Icn | 4.5 kA Icn | 4.5 kA Icn |
Leakage current protection level | Category A | Category A | Category A |
Residual current action function technology | The action function is related to the supply voltage | The action function is related to the supply voltage | The action function is related to the supply voltage |
Isolation function | Apply | Apply | Apply |
Control type | Handle | Handle | Handle |
Local signal indication | On/off indication | On/off indication | On/off indication |
Contact position indication | Yes | Yes | Yes |
Leakage current protection | Integrated leakage protection | Integrated leakage protection | Integrated leakage protection |
Mechanical life | 20000 times | 20000 times | 20000 times |
Electrical life | 10000 times 25 A | 10000 times 32 A | 10000 times 40 A |
Installation type | The locking clip is locked | The locking clip is locked | The locking clip is locked |
Installation method | DIN rail mounting | DIN rail mounting | DIN rail mounting |
Wiring capability | M4.2 terminals (upper or lower wiring) – < = 16 mm² | M4.2 terminals (upper or lower wiring) – < = 16 mm² | M4.2 terminals (upper or lower wiring) – < = 16 mm² |
Tightening torque | 2.5 N.m upper or lower wiring | 2.5 N.m upper or lower wiring | 2.5 N.m upper or lower wiring |
Width (multiple of 9mm) | 4 | 4 | 4 |
height | 77 mm | 77 mm | 77 mm |
width | 35.45 mm – 0.33…0.48 mm | 35.45 mm – 0.33…0.48 mm | 35.45 mm – 0.33…0.48 mm |
depth | 75.5 mm | 75.5 mm | 75.5 mm |
environment | |||
Compliance with standards | IEC 61009 | IEC 61009 | IEC 61009 |
GB 16917 | GB 16917 | GB 16917 | |
Product certification | CCC | CCC | CCC |
Operating temperature | -25… 55 °C | -25… 55 °C | -25… 55 °C |
Storage ambient temperature | -40… 80 °C | -40… 80 °C | -40… 80 °C |
Packaging unit | |||
Unit Type of Package 1 | PCE | PCE | PCE |
Number of Units in Package 1 | 1 | 1 | 1 |
Package 1 Height | 7.6 cm | 7.6 cm | 7.6 cm |
Package 1 Width | 3.6 cm | 3.6 cm | 3.6 cm |
Package 1 Length | 7.7 cm | 7.7 cm | 7.7 cm |
Package 1 Weight | 203 g | 203 g | 203 g |
Unit Type of Package 2 | BB1 | BB1 | BB1 |
Number of Units in Package 2 | 6 | 6 | 6 |
Package 2 Height | 8.4 cm | 8.4 cm | 8.4 cm |
Package 2 Width | 9.2 cm | 9.2 cm | 9.2 cm |
Package 2 Length | 22 cm | 22 cm | 22 cm |
Package 2 Weight | 1.242 kg | 1.242 kg | 1.242 kg |
Unit Type of Package 3 | CAR | CAR | CAR |
Number of Units in Package 3 | 48 | 48 | 48 |
Package 3 Height | 20 cm | 20 cm | 20 cm |
Package 3 Width | 27.8 cm | 27.8 cm | 27.8 cm |
Package 3 Length | 37.6 cm | 37.6 cm | 37.6 cm |
Package 3 Weight | 10 kg | 10 kg | 10 kg |
Contract warranty | |||
Warranty | 18 months | 18 months | 18 months |
Weight | N/A |
---|---|
Dimensions | N/A |
INOSAKI Limited
RM B 5/F Gaylord Comm,
Bldg 114-118 Lockhart Rd.
Hong Kong
INOSAKI Sdn. Bhd.
2-1-9, Ground Floor, One Square, Tingkat Mahsuri 1,
11900 Bayan Lepas, Penan
INOSAKI Pte. Ltd.
101 Upper Cross Street,
No. 06-17, People’s Park Centre,