Omron E2F- X1R/X2/X5/X10 Series- Cylindrical Proximity Sensors

$ 234.74$ 329.78

SKU: N/A

Omron produce industrial sensors range such as fiber sensors, photoelectric sensors, displacement sensors/ measurement sensors, proximity sensors, photomicro sensors and rotary encodes.

Features

• IP68 protection.

• Mutual interference prevention with models with different frequencies is also available.

 

Lineup

SENSORS

Model Sensing distance Output configuration Model
Operation mode
NO NC
Shielded
456_lu_1_1
M8 1.5 mm DC 3-wire, NPN E2F-X1R5E1 2M E2F-X1R5E2 2M
DC 3-wire, PNP E2F-X1R5F1 2M E2F-X1R5F2 2M
AC 2-wire E2F-X1R5Y1 2M E2F-X1R5Y2 2M
M12 2 mm DC 3-wire, NPN E2F-X2E1 2M * E2F-X2E2 2M *
DC 3-wire, PNP E2F-X2F1 2M E2F-X2F2 2M
AC 2-wire E2F-X2Y1 2M * E2F-X2Y2 2M *
M18 5 mm DC 3-wire, NPN E2F-X5E1 2M * E2F-X5E2 2M *
DC 3-wire, PNP E2F-X5F1 2M * E2F-X5F2 2M
AC 2-wire E2F-X5Y1 2M * E2F-X5Y2 2M *
M30 10 mm DC 3-wire, NPN E2F-X10E1 2M * E2F-X10E2 2M *
DC 3-wire, PNP E2F-X10F1 2M E2F-X10F2 2M
AC 2-wire E2F-X10Y1 2M * E2F-X10Y2 2M *

* Models with different frequencies are also available. The model numbers are E2F-X[][][]5 (e.g., E2F-X5E15).

 

 Specifications
Model E2F-X1R5E[] E2F-X1R5F[] E2F-X1R5Y[] E2F-X2E[] E2F-X2F[] E2F-X2Y[] E2F-X5E[] E2F-X5F[] E2F-X5Y[] E2F-X10E[] E2F-X10F[] E2F-X10Y[]
Sensing distance 1.5 mm ±10% 2 mm ±10% 5 mm ±10% 10 mm ±10%
Set distance 0 to 1.2 mm 0 to 1.6 mm 0 to 4 mm 0 to 8 mm
Differential travel 10% max. of sensing distance
Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on Data Sheet.)
Standard sensing object Iron, 8 × 8 × 1 mm Iron, 12 × 12 × 1 mm Iron, 18 × 18 × 1 mm Iron, 30 × 30 × 1 mm
Response frequency *1 E/F Models: 2 kHz,
Y Models: 25 Hz
E/F Models: 1.5 kHz,
Y Models: 25 Hz
E/F Models: 600 Hz,
Y Models: 25 Hz
E/F Models: 400 Hz,
Y Models: 25 Hz
Power supply voltage
(operating voltage range)
E/FModels: 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
Y Models: 24 to 240 VAC (20 to 264 VAC)
Current consumption E/FModels: 17 mA max.
Leakage current Y Models: 1.7 mA max. at 200 VAC (Refer to Engineering Data on Data Sheet.)
Control
output
Load current E/FModels: 200 mA max.
Y Models: 5 to 100 mA
E/FModels: 200 mA max.
Y Models: 5 to 300 mA
Residual voltage E/FModels: 2 V max. (Load current: 200 mA, Cable length: 2 m)
Y Models: Refer to Engineering Data on Data Sheet.
Indicators E1 Models: Detection indicator (red), E2/F1/F2 Models: Operation indicator (red)
Y Models: Operation indicator (red)
Operation mode
(with sensing object approaching)
E1/F1/Y1 Models: NO
E2/F2/Y2 Models: NC
Refer to the timing charts under I/O Circuit Diagrams on Data Sheet for details.
Protection circuits E/F Models: Reverse polarity protection, Load short-circuit protection, Surge suppressor; Y Models: None
Ambient temperature range Operating/Storage: -25 to 70°C (with no icing or condensation)
Ambient humidity range Operating/Storage: 35% to 95%
Temperature influence ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C
Voltage influence E/F Models: ±2.5% max. of sensing distance at rated voltage in rated voltage ±15% range
Y Models: ±1% max. of sensing distance at rated voltage in rated voltage ±10% range
Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength E/F Models: 1,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case
Y Models: (M8 Models): 2,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case
(Other M8 Models): 4,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions
Degree of protection IEC 60529 IP68, in-house standards: oil-resistant *2
Connection method Pre-wired Models (Standard cable length: 2 m)
Weight (packed state) Approx. 40 g Approx. 50 g Approx. 130 g Approx. 170 g
Materials Case Polyarylate resin
Sensing surface
Clamping nuts Polyacetal
Accessories Instruction manual
*1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance.
*2. When using the Sensor in environments subject to splashing cutting oil, deterioration may result due to the additives in the oil. The E2E is recommended in such environments.

 

OMRON Test Method

Usage conditions: 10 m or less under water in natural conditions
1. No water ingress after 1 hour under water at 2 atmospheres of pressure.
2. Sensing distance and insulation resistance specifications must be met after 20 repetitions of 1 hour in 0°C water and 1 hour in 70°C water.

Related products