Omron produce industrial sensors range such as fiber sensors, photoelectric sensors, displacement sensors/ measurement sensors, proximity sensors, photomicro sensors and rotary encodes.
Features
SUS316L Body, IP69K Protection, Resistant to High Temperatures and Detergents
Improved resistance to detergents and rusting
Applicable to 120°C (with DC 3-wire connection)
(Heat resistance verified to 1,000 hours.)
Resists typical detergents and disinfectants used in the food industry
Water-resistant under high-temperature, high-pressure cleaning based on DIN 40050-9.
(Pressure: 8,000 to 10,000 kPa, Water temperature: 80°C, For 30 s at all angles)
Lineup
Sensors
Pre-wired Models
Appearance | Sensing distance | Output configuration | Operation mode: NO | Operation mode: NC | |
---|---|---|---|---|---|
M12 | 3 mm | DC 2-wire (polarity) | E2EH-X3D1 2M | E2EH-X3D2 2M | |
DC 2-wire (no polarity) * | E2EH-X3D1-T 2M | — | |||
DC 3-wire (PNP) | E2EH-X3B1 2M | E2EH-X3B2 2M | |||
DC 3-wire (NPN) | E2EH-X3C1 2M | E2EH-X3C2 2M | |||
M18 | 7 mm | DC 2-wire (polarity) | E2EH-X7D1 2M | E2EH-X7D2 2M | |
DC 2-wire (no polarity) * | E2EH-X7D1-T 2M | — | |||
DC 3-wire (PNP) | E2EH-X7B1 2M | E2EH-X7B2 2M | |||
DC 3-wire (NPN) | E2EH-X7C1 2M | E2EH-X7C2 2M | |||
M30 | 12 mm | DC 2-wire (polarity) | E2EH-X12D1 2M | E2EH-X12D2 2M | |
DC 2-wire (no polarity) * | E2EH-X12D1-T 2M | — | |||
DC 3-wire (PNP) | E2EH-X12B1 2M | E2EH-X12B2 2M | |||
DC 3-wire (NPN) | E2EH-X12C1 2M | E2EH-X12C2 2M |
Connector Models (M12)
Appearance | Sensing distance | Output configuration | Operation mode: NO | Operation mode: NC | |
---|---|---|---|---|---|
M12 | 3 mm | DC 2-wire (polarity) | E2EH-X3D1-M1G | E2EH-X3D2-M1G | |
DC 3-wire (PNP) | E2EH-X3B1-M1 | E2EH-X3B2-M1 | |||
DC 3-wire (NPN) | E2EH-X3C1-M1 | E2EH-X3C2-M1 | |||
M18 | 7 mm | DC 2-wire (polarity) | E2EH-X7D1-M1G | E2EH-X7D2-M1G | |
DC 3-wire (PNP) | E2EH-X7B1-M1 | E2EH-X7B2-M1 | |||
DC 3-wire (NPN) | E2EH-X7C1-M1 | E2EH-X7C2-M1 | |||
M30 | 12 mm | DC 2-wire (polarity) | E2EH-X12D1-M1G | E2EH-X12D2-M1G | |
DC 3-wire (PNP) | E2EH-X12B1-M1 | E2EH-X12B2-M1 | |||
DC 3-wire (NPN) | E2EH-X12C1-M1 | E2EH-X12C2-M1 |
Accessories (Order Separately)
Sensor I/O Connectors (M12, Sockets on One Cable End)
(Models for Connectors: A Connector is not provided with the Sensor. Be sure to order a Connector separately.)
Appearance | Cable length | Sensor I/O Connector model | Applicable Proximity Sensors | |
---|---|---|---|---|
Straight | 2 m | XS2F-E421-D80-E | E2EH-X[]D[]-M1G E2EH-X[]B[]-M1 E2EH-X[]C[]-M1 |
|
5 m | XS2F-E421-G80-E | |||
L-shape | 2 m | XS2F-E422-D80-E | ||
5 m | XS2F-E422-G80-E |
Specifications
E2EH-X[]D[] DC 2-Wire Models
Size Shielded Model |
M12 | M18 | M30 | |
Shielded | ||||
E2EH-X3D[] | E2EH-X7D[] | E2EH-X12D[] | ||
Sensing distance | 3 mm | 7 mm | 12 mm | |
Set distance *1 | 0 to 2.4 mm | 0 to 5.6 mm | 0 to 9.6 mm | |
Differential travel | 15% max. of sensing distance | |||
Response frequency *2 | 500 Hz | 300 Hz | 100 Hz | |
Detectable object | Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Datasheet.) | |||
Leakage current | 0.8 mA max. | |||
Power supply voltage (operating voltage range) |
12 to 24 VDC, ripple (p-p): 10% max. (10 to 32 VDC, however, 24 VDC max. at temperatures over 100 ° C) |
|||
Control Output | Load Current | 3 to 100 mA (however, 3 to 50 mA at 100 to 110 ° C) | ||
Residual voltage *3 | Polarity Models: 3 V max. No polarity Models: E2EH-X[]D[]-T : (5 V max. *3 (Load current: 100 mA, Cable length 2 m) |
|||
Indicators | D1 Models: Operation indicator (red), Setting indicator (yellow) D2 Models: Operation indicator (yellow) |
|||
Operation mode (with sensing object approaching) |
D1 Models: NO D2 Models: NC Refer to Datasheet. |
|||
Protection circuits | Surge suppressor, Load short-circuit protection | |||
Ambient temperature range |
Operating: 0 to 100 ° C (0 to 110 ° C 1,000 h) *4 Storage: – 25 to 70 ° (with no icing or condensation) |
|||
Ambient humidity range | 35% to 95% | |||
Temperature influence | ± 10% max. of sensing distance at 23 ° C in the temperature range of 0 to 70 ° C.
± 15% max. of sensing distance at 23 ° C in the temperature range of 70 to 100 ° C. – 15% to +20% of sensing distance at 23 ° C in the temperature range of 100 to 110 ° C. |
|||
Voltage influence | ± 10% max. of sensing distance at rated voltage in the 15% rated voltage range. | |||
Insulation resistance | 50 M Ω min. (at 500 VDC) between current-carrying parts and case | |||
Dielectric strength | 1,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case | |||
Vibration resistance | Destruction: 10 to 55 Hz 1.5-mm double amplitude for 2 hours each in X, Y and Z directions | |||
Shock resistance | Destruction: 1,000 m/s2, 10 times each in X, Y and Z directions | |||
Degree of protection | IEC IP67, DIN 40050-9 IP69K *5 | |||
Connection method | Pre-wired Models (Standard cable length 2 m), Connector Models | |||
Weight (packed state) |
Pre-wired Models |
Approx. 80 g | Approx. 145 g | Approx. 220 g |
Connector Models |
Approx. 30 g | Approx. 55 g | Approx. 125 g | |
Materials | Case, clamping nut |
Stainless steel (SUS316L) | ||
Sensing surface |
PBT | |||
Cable | Heat-resistant PVC cable (Pre-wired model) | |||
Accessories | Instruction manual | |||
Standard sensing object | Iron, 12 × 12 × 1 mm | Iron 21 × 21 × 1 mm | Iron 36 × 36 × 1 mm |
*1. Use the yellow indicator on D1 Models as a guide.
*3. The residual voltage of each E2EH-X[]D[] DC 2-Wire Model is 5 V. When connecting to a device, make sure that the device can withstand the residual voltage. (Refer to Data Sheet.)
*4. Operation with power supplied for 1,000 h has been verified at 110°C. Do not bend the cable repeatedly at 100°C or higher.
*5. IP69K Degree of Protection Specification IP69K is a protection standard against high temperature and high-pressure water defined in the German standard DIN 40050, Part 9. The test piece is sprayed with water at 80°C at a water pressure of 80 to 100 BAR using a specified nozzle shape at a rate of 14 to 16 liters/min.
The distance between the test piece and nozzle is 10 to 15 cm, and water is sprayed horizontally for 30 seconds each at 0°, 30°, 60°, and 90° while rotating the test piece on a horizontal plane.
E2EH-X[]C[]/B[] DC 3-Wire Models
Size Shielded Model |
M12 | M18 | M30 | |
---|---|---|---|---|
Shielded | ||||
E2EH-X3C[]/B[] | E2EH-X7C[]/B[] | E2EH-X12C[]/B[] | ||
Sensing distance | 3 mm±10% | 7 mm±10% | 12 mm±10% | |
Set distance *1 | 0 to 2.4 mm | 0 to 5.6 mm | 0 to 9.6 mm | |
Differential travel | 15% max. of sensing distance | |||
Detectable object | Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Datasheet.) | |||
Standard sensing object | Iron, 12 × 12 × 1 mm | Iron 21 × 21 × 1 mm | Iron 36 × 36 × 1 mm | |
Response frequency *2 | 500 Hz | 300 Hz | 100 Hz | |
Power supply voltage (operating voltage range) |
12 to 24 VDC, ripple (p-p): 10% max. (10 to 32 VDC, however, 24 VDC max. at temperatures over 100 ° C) |
|||
Current consumption | 10 mA max. | |||
Control output |
Load current |
100 mA max. (however, 50 mA max. at 100 to 120 ° C) | ||
Residual voltage |
2 V max. (Load current: 100 mA, Cable length 2 m) | |||
Indicators | Operation indicator (yellow) | |||
Operating mode (with sensing object approaching) |
C1 Models: NO C2 Models: NC B1 Models: NO B2 Models: NC Refer to Datasheet. |
|||
Protection circuits | Power supply reverse polarity protection, Surge suppressor, Load short-circuit protection, Reversed output polarity protection | |||
Ambient temperature range |
Operating: 0 to 100 ° C (0 to 120 ° C 1,000 h) *2 Storage: – 25 to 70 ° C (with no icing or condensation) |
|||
Ambient humidity range | 35% to 95% | |||
Temperature influence | ± 10% max. of sensing distance at 23 ° C in the temperature range of 0 to 70 ° C. ± 15% max. of sensing distance at 23 ° C in the temperature range of 70 to 100 ° C. – 15% to 20% of sensing distance at 23 ° C in the temperature range of 100 to 120 ° C. |
|||
Voltage influence | 10% max. of sensing distance at rated voltage in the 15% rated voltage range. | |||
Insulation resistance | 50 M Ω min. (at 500 VDC) between current-carrying parts and case | |||
Dielectric strength | 1,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case | |||
Vibration resistance | Destruction: 10 to 55 Hz 1.5-mm double amplitude for 2 hours each in X, Y and Z directions | |||
Shock resistance | Destruction: 1,000 m/s2, 10 times each in X, Y and Z directions | |||
Degree of protection | IEC IP67, DIN 40050-9 IP69K | |||
Connection method | Pre-wired Models (Standard cable length 2 m), Connector Models | |||
Weight (packed state) |
Pre-wired Models |
Approx. 80 g | Approx. 145 g | Approx. 220 g |
Connector Models |
Approx. 30 g | Approx. 55 g | Approx. 125 g | |
Materials | Case, clamping nut |
Stainless steel (SUS316L) | ||
Sensing surface |
PBT | |||
Cable | Heat-resistant PVC cable (Pre-wired Model) | |||
Accessories | Instruction manual |
*2. Operation with power supplied for 1,000 h has been verified at 120°C. Do not bend the cable repeatedly at 100°C or higher.
Resistance to Detergents, Disinfectants, and Chemicals
- Performance is assured for typical detergents and disinfectants, but performance may not be maintained for some detergents and disinfectants. Refer to the following table when using these agents.
- The E2EH passed testing for resistance to detergents and disinfectants performed using the items in the following table. Refer to this table when considering use of detergents and disinfectants.
Category | Product name | Concentration | Temperature | Time |
---|---|---|---|---|
Chemical | Sodium hydroxide (NaOH) | 1.5% | 70 ° C | 240h |
Potassium hydroxide (KOH) | 1.5% | 70 ° C | 240h | |
Phosphoric acid (H3PO4) | 2.5% | 70 ° C | 240h | |
Sodium hypochlorite (NaClO) | 0.3% | 25 ° C | 240h | |
Hydrogen peroxide (H2O2) | 6.5% | 25 ° C | 240h | |
Alkaline foam detergent | P3-topax-66s (Manufactured by Ecolab) | 3.0% | 70 ° C | 240h |
Acidic foam detergent | P3-topax-56 (Manufactured by Ecolab) | 5.0% | 70 ° C | 240h |
Disinfectant | P3-oxonia active 90 (Manufactured by Ecolab) | 1.0% | 25 ° C | 240h |
Test Conditions
After the test is completed, check that no problems exist with the following product characteristics.
(1) Appearance (no damage that will affect the product characteristics)
(2) Operation Check (ON/OFF)
(3) Insulation resistance: 50 MΩ min. (at 500 VDC)
(4) Dielectric strength (1,000 VAC for 1 minute)
(5) Water resistance (IP67)