Omron E2C-EDA EDR/ED/EV Series- Proximity Sensors – Seperate Amplifier

USD $ 760.20USD $ 1,068.48

SKU: N/A

Omron produce industrial sensors range such as fiber sensors, photoelectric sensors, displacement sensors/ measurement sensors, proximity sensors, photomicro sensors and rotary encodes.

 

Features

• Wide variety of Sensor Heads to select according to the application. Flexible cables are used between Preamplifiers and Amplifier Units of the Sensor Heads.

• High resistance to changes in ambient temperature.
Temperature characteristics of 0.08%/°C (for 5.4-dia. models).

• Make simple and reliable detection settings with micron-level precision using the teaching function.

• Check the sensing excess gain level on the digital display.

• Support for high-precision positioning and screening with fine positioning to maximize variations.

• The E2C-EDA0 supports an EtherCAT Sensor Communications Unit or CompoNet Sensor Communications Unit.

 

Lineup

Sensors

Sensor Heads

Type Appearance Sensing
distance
Repeat
accuracy
Cable
specification
Model
Shielded Cylindrical

1518_lu_1_1
3 dia. × 18 mm 0.6 mm 1 μm Free cutting *2 E2C-EDR6-F
5.4 dia. × 18 mm 1 mm 1 μm Standard *2 E2C-ED01
Free cutting *2 E2C-ED01-F
With Protective
Spiral Tube *1 *2
E2C-ED01-S
8 dia. × 22 mm 2 mm 2 μm Standard *2 E2C-ED02
Free cutting *2 E2C-ED02-F
With Protective
Spiral Tube *1 *2
E2C-ED02-S
Screw

1518_lu_1_2
M10 × 22 mm 2 mm 2 μm Standard *2 E2C-EM02
Free cutting *2 E2C-EM02-F
With Protective
Spiral Tube *1 *2
E2C-EM02-S
Flat

1518_lu_1_3
30 × 14 × 4.8 mm 5 mm 2 μm Standard *2 E2C-EV05
Free cutting *2 E2C-EV05-F
With Protective
Spiral Tube *1 *2
E2C-EV05-S
Unshielded Screw

1518_lu_1_4
M18 × 46.3 mm 7 mm 5 μm Standard *2 E2C-EM07M
Free cutting *2 E2C-EM07M-F
With Protective
Spiral Tube *1 *2
E2C-EM07M-S
Heat-
resistant
Screw

1518_lu_1_5
M12 × 22 mm 2 mm 2 μm Standard *2 E2C-EM02H

*1 Ask your OMRON representative for information on the Protective Spiral Tube.
*2 Overall length of free-cut cable: 3.5 m, Length from the Sensor Head to the Preamplifier: 0.5 m (Overall length of the standard cable with Protective Spiral Tube: 2.5 m, Length from the Sensor Head to the Preamplifier: 2 m)

 

Amplifier Units

Amplifier Units with Cables

Item Appearance Functions Model
NPN output PNP output
Advanced
models
Twin-output models
1518_lu_2_1
Area output, open
circuit detection,
differential operation
E2C-EDA11 2M E2C-EDA41 2M
External-input models Remote setting,
differential operation
E2C-EDA21 2M E2C-EDA51 2M

 

Amplifier Units with Wire-saving Connectors

(An Amplifier Unit Connector (sold separately) is required.)

Item Appearance Functions Model
NPN output PNP output
Advanced
models
Twin-output models
1518_lu_3_1
Area output, open
circuit detection,
differential operation
E2C-EDA6 E2C-EDA8
External-input models Remote setting,
differential operation
E2C-EDA7 E2C-EDA9

Note: These models allow you to use an E3X-DRT21-S VER.3 Sensor Communications Unit. When using the E3X-DRT21-S VER.3, use an E3XCN02 Connector without a Cable for the Wire-saving Connector.

 

Amplifier Unit with Connector for EtherCAT or CompoNet Sensor Communications Units

Item Appearance Functions Model Applicable Sensor
Communications Unit
Advanced
model
Twin-output
model
1518_lu_4_1
Area output, open circuit detection,
differential operation
E2C-EDA0 E3X-ECT
E3X-CRT

 

Wire-saving Connectors (Order Separately)

Note: Protector seals provided.

Item Appearance Cable length No. of conductors Model
Master Connector
1518_lu_5_1
2 m 4 E3X-CN21
Slave Connector
1518_lu_5_2
2 E3X-CN22

 

Ordering Precaution for Amplifier Units with Wire-saving Connectors

A Connector is not provided with the Amplifier Unit.
Refer to the following tables when ordering.

Amplifier Unit Applicable Connector (Order Separately)
Model NPN output PNP output Master Connector Slave Connector
Advanced models E2C-EDA6 E2C-EDA8 E3X-CN21 E3X-CN22
E2C-EDA7 E2C-EDA9

 

When Using 5 Amplifier Units

Amplifier Units (5 Units) 1 Master Connector 4 Slave Connectors

 

Mobile Console (Order Separately)

Appearance Model Remarks
1518_lu_8_1
E3X-MC11-SV2
(model number of set)
Mobile Console with Head, Cable, and AC adapter
provided as accessories
1518_lu_8_2
E3X-MC11-C1-SV2 Mobile Console
1518_lu_8_3
E3X-MC11-H1 Head
1518_lu_8_4
E39-Z12-1 Cable (1.5 m)
Note: Use the E3X-MC11-SV2 Mobile Console with E2C-EDA-series Amplifier Units. If you use a Mobile Console like the E3X-MC11-S, some functions may not operate. For details, refer to Ratings and Specifications for E3X-DA-S/MDA.

 

Accessories (Order Separately)

Mounting Bracket

A Mounting Bracket is not provided with the Amplifier Unit. Order a Mounting Bracket separately if required.

Appearance Model Quantity
1518_lu_9_1
E39-L143 1

 

End Plate

An End Plate is not provided with the Amplifier Unit. Order an End Plate separately if required.

Appearance Model Quantity
1518_lu_10_1
PFP-M 1

 

Extension Cables for Sensor Head

An Extension Cable is not provided with the Amplifier Unit. Order an Extension Cable separately if required.

Cable length Model Quantity
2 m E22-XC2R 1
7 m E22-XC7R

 

SPECIFICATIONS

Sensor Heads

Model E2C-
EDR6-F
E2C-
ED01(-[])
E2C-
ED02(-[])
E2C-
EM02(-[])
E2C-
EM07(-[])
E2C-
EV05(-[])
E2C-
EM02H
3 dia. ×
18 mm
5.4 dia.
× 18 mm
8 dia. ×
22 mm
M10 ×
22 mm
M18 ×
46.3 mm
30 × 14
× 4.8 mm
M12 ×
22 mm
Sensing distance 0.6 mm 1 mm 2 mm 7 mm 5 mm 2 mm
Sensing object Magnetic metal
(The sensing distance will decrease when sensing non-magnetic metal. Refer to
Engineering Data (Reference Value) on Catalog.)
Standard sensing object 5 × 5 × 3 mm 10 × 10 × 3 mm 22 × 22
× 3 mm
15 × 15
× 3 mm
20 × 20
× 3 mm
Material: iron (S50C)
Repeat accuracy *1 1 μm 2 μm 5 μm 2 μm
Hysteresis distance Variable
Temper-
ature
charac-
teristic
*1
Sensor Head 0.3%/°C 0.08%/°C 0.04%/°C 0.2%/°C
Preamplifier and
Amplifier
0.08%/°C
Ambient
temper-
ature
*2
Operating -10°C to 60°C (with no icing or condensation) -10°C to
200°C *3
Storage -10°C
to 60°C
(with no
icing or
con-
densation)
-20°C to 70°C (with no icing or condensation)
Ambient humidity Operating/storage: 35% to 85% (with no condensation)
Insulation resistance 50 MΩ min. (at 500 VDC)
Dielectric strength 1,000 VAC at 50/60 Hz for 1 min between current carry parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z
directions
Shock resistance Destruction: 500 m/s2 for 3 times each in X, Y, and Z directions
Degree of protection IEC60529 IP67 IEC60529
IP60 *4
Connection method Connector (standard cable length: 2.5 m (2 m between Head and Preamplifier)
“-F” model cable length: 3.5 m (0.5 m between Head and Preamplifier)
Weight (packed state) Approx. 120 g (Models with protective spiral tube (“-S” models) are approx. 90 g heavier.)
Material Sensor
Head
Case Brass Stainless
steel
Brass Zinc Brass
Sensing
surface
Heat-resistant ABS PEEK
Clamping
nut
Nickel-plated brass Nickel-
plated brass
Toothed
washer
Zinc-plated iron Zinc-plated
iron
Preamplifier PES
Accessories Preamplifier Mounting Brackets, Instruction Manual
*1 The repeat accuracy and temperature characteristic are for a standard sensing object positioned midway through the rated sensing distance.
*2 A sudden temperature rise even within the rated temperature range may degrade characteristics.
*3 For the Sensor Head only without the preamplifier (−10 to 60°C). With no icing or condensation.
*4 Do not operate in areas exposed to water vapor because the enclosure is not waterproof.

 

Amplifier Units

Type Advanced Models with Twin Outputs Advanced Models with
External Inputs
Pre-wired
Model
Model with
Wiresaving
Connector
Model for Sensor
Communications
Unit
Pre-wired
Model
Model with
Wiresaving
Connector
Model NPN output E2C-EDA11 E2C-EDA6 E2C-EDA0 *1 E2C-EDA21 E2C-EDA7
PNP output E2C-EDA41 E2C-EDA8 E2C-EDA51 E2C-EDA9
Supply voltage 12 to 24 VDC ±10%, ripple (p-p): 10% max.
Power consumption 1,080 mW max. (current consumption: 45 mA at power supply voltage of 24 VDC)
Control output Load power supply voltage: 26.4 VDC max.; NPN/PNP open collector output; load current:
50 mA max. (residual voltage: 1 V max.)
Response
time
Super-high-
speed mode
*2
150 μs for operation and
reset respectively
150 μs for operation and reset
respectively
High-speed
mode
300 μs for operation and reset respectively
Standard
mode
1 ms for operation and reset respectively
High-
resolution
mode
4 ms for operation and reset respectively
Functions Differential
detection
Switchable between single edge and double edge detection mode
Single edge: Can be set to 300 μs, 500 μs, 1 ms, 10 ms, or 100 ms
Double edge: Can be set to 500 μs, 1 ms, 2 ms, 20 ms, or 200 ms.
Timer
function
Select from OFF-delay, ON-delay, or one-shot timer.
1 ms to 5 s (1 to 20 ms set in 1-ms increments, 20 to 200 ms set in 10-ms increments,
200 ms to 1 s set in 100-ms increments, and 1 to 5 s set in 1 s-increments)
Zero-reset Negative values can be displayed.
Zero-reset is accompanied by a change of detection distance.
After zero-reset, some threshold level may also cause a change of the indication by
influence of other settings.
Initial reset Settings can be returned to defaults as required.
Mutual
interference
prevention
Possible for up to 5 Units. *2
Intermittent oscillation method (Response time = (number of Units connected + 1) ×
15 ms)
Hysteresis
settings
Setting range: 10 to 2,000
I/O settings Output setting (Select from channel 2 output, area
output, self-diagnosis, or open circuit detection.)
Input setting (Select from
teaching, fine positioning, zero-
reset, synchronous detection.)
Digital display Select from the following: Incident level + threshold, incident level percentage +threshold,
incident light peak level + incident light bottom level (updated with output), long bar display,
incident level + peak hold, incident level + channel
Display orientation Switching between normal/reversed display is possible.
Ambient temperature
*3
Operating:
When connecting 1 to 2 Units: -10°C to 55°C,
When connecting 3 to 5 Units: -10°C to 50°C,
When connecting 6 to 16 Units: -10°C to 45°C
When used in combination with an EDR6-F
When connecting 3 to 4 Units: -10°C to 50°C,
When connecting 5 to 8 Units: -10°C to 45°C,
When connecting 9 to 16 Units: -10°C to 40°C
Storage: -20°C to 70°C (with no icing)
Ambient humidity Operating/storage: 35% to 85% (with no condensation)
Insulation resistance 20 MΩ min. (at 500 VDC)
Dielectric strength 1,000 VAC at 50/60 Hz for 1 min
Vibration resistance
(Destruction)
10 to 55 Hz with a 1.5-mm
double amplitude for 2 hours
each in X, Y, and Z directions
10 to 150 Hz with a
0.7-mm double
amplitude for 80
min each in X, Y,
and Z directions
10 to 55 Hz with a 1.5-mm
double amplitude for 2 hours
each in X, Y, and Z directions
Shock resistance
(Destruction)
500 m/s2 for 3 times each in
X, Y, and Z directions
150 m/s2 for 3
times each in X,
Y, and Z directions
500 m/s2 for 3 times each in X,
Y, and Z directions
Degree of protection IEC60529 IP50
Connection method Pre-wired Wire-saving
connector
Connector for Sensor
Communications Unit
Pre-wired Wire-saving
connector
Weight (packed state) Approx. 100 g Approx. 55 g Approx. 55 g Approx. 100 g Approx. 55 g
Material Case PBT (polybutylene terephthalate)
Cover Polycarbonate
*1 This model allow you to use an E3X-ECT EtherCAT Sensor Communications Unit or E3X-CRT CompoNet Sensor Communications Unit.
*2 Communications functions, mutual interference prevention, and communications with the Mobile Console are all disabled if the detection mode is set to the super-high-speed mode.
*3 The following temperature ranges apply for operation when an E3X-ECT or E3X-CRT Sensor Communications Unit is used with the E2C-EDA0: Groups of 1 or 2 Amplifier Units: 0 to 55°C, Groups of 3 to 5 Amplifier Units: 0 to 50°C, Groups of 6 to 16 Amplifier Units: 0 to 45°C, Groups of 17 to 30 Amplifier Units (with the E3X-ECT): 0 to 40°C.
The following temperature ranges apply when an E3X-ECT or E3X-CRT Sensor Communications Unit is used with the E2C-EDR6-F: Groups of 3 or 4 Amplifier Units: 0 to 50°C, Groups of 5 to 8 Amplifier Units: 0 to 45°C, Groups of 9 to 16 Amplifier Units: 0 to 40°C, Groups of 17 to 30 Amplifier Units (with the E3X-ECT): 0 to 35°C.