DT50-N1114 Mid Range Distance Sensors – SICK Sensor

$ 522.06

SKU: SICK 1047582

SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.

Part Number: 1047582
Distance Sensor Model: DT50-N1114
OEM Spec Ref 

Mechanics/electronics

Supply voltage Vs DC 15 V … 30 V 1) 2)
Ripple ≤ 5 Vpp 3)
Power consumption ≤ 2.1 W 4)
Initialization time ≤ 250 ms
Warm-up time ≤ 15 min
Housing material Metal (zinc diecast)
Window material Plastic (PMMA)
Connection type Male connector, M12, 5-pin
Indication LC display, 2 x LED
Weight 200 g
Dimensions (W x H x D) 36.1 mm x 62.7 mm x 57.7 mm
Enclosure rating IP65
Protection class III
  • 1) Limit values, reverse-polarity protected, operation in short-circuit protected network: max. 8 A.
  • 2) For DT50-xxxx4: VS > 15 V.
  • 3) May not fall short of or exceed VS tolerances.
  • 4) Without load.

Performance

Measuring range 200 mm … 10,000 mm, 90 % remission

200 mm … 6,500 mm, 18 % remission

200 mm … 4,000 mm, 6 % remission

Target Natural objects
Resolution 1 mm
Repeatability ≥ 2.5 mm 1) 2) 3)
Accuracy ± 10 mm 4)
Response time 20 ms … 30 ms, 20 ms / 30 ms 3) 5)
Output time ≥ 4 ms 6)
Light source Laser, red
visible red light
Laser class 2 (IEC 60825-1:2014, EN 60825-1:2014) 7)
Typ. light spot size (distance) 15 mm x 15 mm (10 m)
Additional function Set moving average: fast/slow, switching mode: distance to object (DtO), teach-in, scaling and inversion of digital output, set hysteresis, teach-in, scaling and inversion of analog output, Multifunctional input: laser off / external teach / deactivated, switch-off display, reset to factory default, lock user interface
Average laser service life (at 25 °C) 100,000 h
  • 1) Equivalent to 1 σ.
  • 2) 6 % … 90 % remission.
  • 3) Dependent on the averaging setting: fast/slow.
  • 4) 90 % remission.
  • 5) Lateral entry of the object into the measuring range.
  • 6) Continuous change of distance in measuring range.
  • 7) Wavelength: 658 nm; max. output: 180 mW; pulse duration: 5 ns; duty cycle: 1/200.

Interfaces

Digital output
Number 1) 2)
Type NPN
Maximum output current IA ≤ 100 mA
Analog output
Number 1
Type Voltage output
Voltage 0 V … 10 V, ≥ 5,000 Ω
Resolution 16 bit
Multifunctional input (MF) 1 x 3) 4)
Hysteresis 10 mm … 1,000 mm
  • 1) Output Q short-circuit protected.
  • 2) NPN: HIGH = < 2.5 V / LOW = VS.
  • 3) Response time ≤ 15ms.
  • 4) NPN: HIGH = ≤ 2.5 V / LOW = VS.

Ambient data

Ambient temperature, operation –30 °C … +65 °C

–30 °C … +80 °C, operation with 2 cooling plates

–30 °C … +140 °C, operation with 2 cooling plates and protection filter

Ambient temperature, storage –40 °C … +75 °C
Max. rel. humidity (not condensing) ≤ 95 %
Typ. Ambient light immunity 40,000 lx
Vibration resistance EN 60068-2-6, EN 60068-2-64
Shock resistance EN 60068-2-27