SICK 1047405 DS50-P1122 Dual PNP Laser Distance Sensor

USD 564.46

DS50-P1122 provides two PNP distance outputs,0.2–10 m range on90% remission,class1 red laser,fast/slow averaging,teach-in and IP65 protection.

SKU SICK-1047405 Category
Laser Distance Sensors - SICK Dx50

SICK DS50-P1122 Dual PNP Laser Distance Sensor

BrandSICK
Model IdentifierDS50-P1122
Official Part Number1047405

Technical Overview

The SICK DS50-P1122 evaluates distance to natural objects with a class 1 red time-of-flight laser and two PNP switching outputs. Measuring range is 0.2–10 m at 90% remission, 0.2–6 m at 18% remission and 0.2–4 m at 6% remission. Fast and slow averaging give specified responses of 20/100 ms and switching frequencies of 25/5 Hz. Teachable switching-point, switching-window and background modes, adjustable hysteresis and a laser-off/external-teach input adapt integration. An LC display and two output LEDs support setup. The IP65 zinc-diecast housing has a PMMA window and an M12 five-pin male connector. Startup is at most 350 ms, with measurement warm-up up to fifteen minutes.

Target-dependent0.2–10 m time-of-flight distance sensor with two PNP outputs,class1 red laser,fast/slow averaging and M12 five-pin connection.

Key Features

  • 0.2–10 m at90% remission;0.2–6 m at18%;0.2–4 m at6%
  • 658 nm class1 red laser;typical15 ×15 mm spot at10 m
  • Two PNP outputs;maximum output current≤100 mA
  • Fast/slow averaging;response20/100 ms;switching25/5 Hz
  • Distance-to-object,window and background switching modes
  • Teach-in,scaling,inversion and1–9,999 mm hysteresis
  • Multifunction input for laser-off,external teach or deactivated state
  • LC display,two output LEDs and M12 five-pin male connector
  • 10–30 V DC;≤1.85 W without load;warm-up≤15 min
  • IP65 zinc-diecast housing;PMMA window;−30 to+65 °C operation

Teach distance-based switching conditions for external machine control,with averaging and target reflectivity matched to the required measuring path.

Technical Specification Matrix

ParameterValue
Functional principleTime-of-flight laser distance evaluation
TargetNatural objects
Measuring range200–10,000 mm at90% remission;200–6,000 mm at18%;200–4,000 mm at6%
Display resolution1 mm;manufacturer1000 µm equals1 mm;related to displayed distance
Repeatability≥2.5 mm;1σ;6–90% remission;depends on fast/slow averaging
Displayed-distance accuracy±10 mm at90% remission
AveragingFast or slow
Response time20/100 ms,depending on fast/slow averaging
Switching frequency25/5 Hz,depending on fast/slow averaging
Light sourceVisible red laser;658 nm
Laser class1;IEC60825-1:2014 and EN60825-1:2014
Laser pulse figuresMaximum output120 mW;pulse2.5 ns;duty cycle1/400
Laser handlingDo not intentionally look into the beam or point it at eyes
Typical light spot15 ×15 mm at10 m
Average laser service life100,000 h at25 °C
Digital outputs2 ×PNP;maximum output current≤100 mA;short-circuit protected;HIGH=VS−(<2.5 V),LOW=0 V
Switching modesSwitching point(DtO),switching window,background(ObSB)
Output adjustmentTeach-in,scaling and inversion
Hysteresis1–9,999 mm
Multifunction inputLaser off,external teach or deactivated;input response≤60 ms
Other functionsCrosstalk protection,switch-off display,reset,lock user interface
Power supply10–30 V DC;limit values;reverse-polarity protected
Supply network requirementShort-circuit protected network,max8 A
Power consumption≤1.85 W without load
Supply ripple≤5 Vpp;must remain within supply limits
Initialization time≤350 ms
Warm-up time≤15 min
Indicators and displayLC display;two digital-output status LEDs
ConnectionM12 five-pin male connector
Pin assignment1BN=L+;3BU=M;4BK=Q1;2WH=Q2;5GY=MF
Housing materialZinc diecast
Window materialPMMA plastic
IP ratingIP65
Protection classIII
Operating temperature−30 to+65 °C
Storage temperature−40 to+75 °C
Relative humidity≤95%;non-condensing
Ambient light immunityTypical40,000 lx
Vibration resistanceEN60068-2-6 and EN60068-2-64
Shock resistanceEN60068-2-27
MTTFD101 years
DCavg0%
Physical Weight (kg)0.2
Dimensions L x W x H (cm)5.77 x 3.61 x 7.27

Industrial Applications

1. Setting a carriage approach condition

A carriage station can present a natural target surface along the measuring path and teach the required distance switching point. Its reflectivity determines the available range,so the actual surface is verified before selecting the mounting position. A PNP output reports the configured approach condition to external motion sequencing,and fast or slow averaging is selected to suit the expected movement.

Problem Solved

A taught approach condition gives external sequence control a repeatable positional event along the travel path,helping coordinate the next machine action before the carriage reaches its final location.

Carriage approach PNP switching Averaging

2. Checking the height of a material stack

A stacking station can aim the laser at the top surface and teach a distance condition corresponding to the desired stack height. A switching window can be used for an accepted height region,with external control interpreting the PNP result. Actual target remission,averaging and the15-minute warm-up limit are considered before setting thresholds and validating the intended operating cycle.

Problem Solved

A distance-based height condition lets external stack control distinguish a stack in the selected height region from one that is too high or too low,reducing reliance on a simple occupied-station signal.

Stack height Switching window External control

3. Detecting an object in front of a taught background

A conveyor station can teach background switching with the actual background and present target objects between that surface and the sensor. The object and background are positioned inside the appropriate remission-dependent range,and hysteresis is adjusted for the required switching behavior. External control uses the configured PNP output as the object condition;actual materials and spacing are checked during commissioning.

Problem Solved

A taught background reference helps external sequence control distinguish an object entering the selected space from the background alone,supporting an inspection condition based on distance rather than reflected-light intensity alone.

Background reference Object detection Hysteresis