$ 29.92 – $ 35.86
Main information | ||||
Part Number | GV2ME05C | GV2ME07C | GV2ME08C | GV2ME10C |
Product Series | TeSys Deca | TeSys Deca | TeSys Deca | TeSys Deca |
product name | TeSys GV2 | TeSys GV2 | TeSys GV2 | TeSys GV2 |
product short name | GV2ME | GV2ME | GV2ME | GV2ME |
product type | Breaker | Breaker | Breaker | Breaker |
Applications | Motor protection | Motor protection | Motor protection | Motor protection |
number of poles | 3P | 3P | 3P | 3P |
Additional information | ||||
Grid type | AC | AC | AC | AC |
Network frequency | 50/60 Hz conforming to IEC 60947-2 | 50/60 Hz conforming to IEC 60947-2 | 50/60 Hz conforming to IEC 60947-2 | 50/60 Hz conforming to IEC 60947-2 |
control type | (Push) button | (Push) button | (Push) button | (Push) button |
installation method | Rail installation | Rail installation | Rail installation | Rail installation |
installation location | horizontal vertical | horizontal vertical | Vertical | horizontal vertical |
horizontal direction | ||||
Motor power (kW) | 0.00…0.37 kW at 230 V AC 50/60 Hz | 0.37 kW at 230 V AC 50/60 Hz | 0.75 kW at 230 V AC 50/60 Hz | 1.1 kW at 230 V AC 50/60 Hz |
0.00…0.37 kW at 400 V AC 50/60 Hz | 0.75 kW at 400 V | 1.5 kW at 400 V | 2.2 kW at 400 V | |
0.00…0.37 kW at 415 V AC 50/60 Hz | 0.75 kW at 415 V | 1.5 kW at 415 V | 2.2 kW at 415 V | |
0.37 kW at 440 V AC 50/60Hz | 1.1 kW at 440 V AC 50/60 Hz | 1.5 kW at 440 V AC 50/60 Hz | 3 kW at 440 V AC 50/60 Hz | |
Rated current [In] | 1A | 2.5A | 4A | 6.3A |
Trip unit type | Thermomagnetic | Thermomagnetic | Thermomagnetic | Thermomagnetic |
Electromagnetic trip current | 13A | 33.5A | 51A | 78A |
Thermal overload protection setting range | 0.63…1A | 1.6…2.5 A | 2.5…4A | 4…6.3A |
isolation function | Applies to IEC 60947-1 § 7-1-6 | Applies to IEC 60947-1 § 7-1-6 | Applies to IEC 60947-1 § 7-1-6 | Applies to IEC 60947-1 § 7-1-6 |
Mechanical shock resistance | 0.5 J IK04 | 0.5 J IK04 | 0.5 J IK04 | 0.5 J IK04 |
phase loss sensitivity | Is compliant with IEC 60947-4-1 § 7-2-1-5-2 | Is compliant with IEC 60947-4-1 § 7-2-1-5-2 | Is compliant with IEC 60947-4-1 § 7-2-1-5-2 | Is compliant with IEC 60947-4-1 § 7-2-1-5-2 |
use category | Type AC conforms to IEC 60947-2 | Type AC conforms to IEC 60947-2 | Type AC conforms to IEC 60947-2 | Type AC conforms to IEC 60947-2 |
AC-3 conforms to IEC 60947-4-1 | AC-3 conforms to IEC 60947-4-1 | AC-3 conforms to IEC 60947-4-1 | AC-3 conforms to IEC 60947-4-1 | |
Rated working voltage [Ue] | 690 V AC 50/60 Hz conforming to IEC 60947-2 | 690 V AC 50/60 Hz conforming to IEC 60947-2 | 690 V AC 50/60 Hz conforming to IEC 60947-2 | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
Rated insulation voltage [Ui] | 690 V AC 50/60 Hz conforming to IEC 60947-2 | 690 V AC 50/60 Hz conforming to IEC 60947-2 | 690 V AC 50/60 Hz conforming to IEC 60947-2 | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
600 V AC 50/60 Hz conforming to UL 508 | 600 V AC 50/60 Hz conforming to UL 508 | 600 V AC 50/60 Hz conforming to UL 508 | 600 V AC 50/60 Hz conforming to UL 508 | |
600 V AC 50/60 Hz conforming to CSA C22.2 No 14 | 600 V AC 50/60 Hz conforming to CSA C22.2 No 14 | 600 V AC 50/60 Hz conforming to CSA C22.2 No 14 | 600 V AC 50/60 Hz conforming to CSA C22.2 No 14 | |
Rated impulse withstand voltage [Uimp] | 6 kV according to IEC 947-2 | 6 kV according to IEC 947-2 | 6 kV according to IEC 947-2 | 6 kV according to IEC 947-2 |
power consumption per pole | 2.5W | 2.5W | 2.5W | 2.5W |
Mechanical life | 100000 times | 100000 times | 100000 times | 100000 times |
Electrical life | 100000 cycles for AC-3 at 440 V In | 100000 cycles for AC-3 at 440 V In | 100000 cycles for AC-3 at 440 V In | 100000 cycles for AC-3 at 440 V In |
100000 cycles for AC-3 at 440 V In/2 | 100000 cycles for AC-3 at 440 V In/2 | 100000 cycles for AC-3 at 440 V In/2 | 100000 cycles for AC-3 at 440 V In/2 | |
maximum conversions | 25 cyc/h | 25 cyc/h | 25 cyc/h | 25 cyc/h |
specified load | Continuous according to IEC 60947-4-1 | Continuous according to IEC 60947-4-1 | Continuous according to IEC 60947-4-1 | Continuous according to IEC 60947-4-1 |
Wiring capacity | Power circuit: Screw-in terminals 2 1…6 mm² Cable option: Solid without wire terminals Power circuit: | Power circuit: Screw-in terminals 2 1…6 mm² Cable option: Solid without wire terminals Power circuit: | Power circuit: Screw-in terminals 2 1…6 mm² Cable option: Solid without wire terminals Power circuit: | Power circuit: Screw-in terminals 2 1…6 mm² Cable option: Solid without wire terminals Power circuit: |
Screw-in terminals 2 1.5…6 mm² Cable option: Flexible without wire terminals | Screw-in terminals 2 1.5…6 mm² Cable option: Flexible without wire terminals | Screw-in terminals 2 1.5…6 mm² Cable option: Flexible without wire terminals | Screw-in terminals 2 1.5…6 mm² Cable option: Flexible without wire terminals | |
Power circuit: Screw-in terminals 2 1…4 mm² Cable selection: Flexible with cable terminals | Power circuit: Screw-in terminals 2 1…4 mm² Cable selection: Flexible with wire terminals | Power circuit: Screw-in terminals 2 1…4 mm² Cable selection: Flexible with cable terminals | Power circuit: Screw-in terminals 2 1…4 mm² Cable selection: Flexible with cable terminals | |
Tightening torque | 1.7 Nm via screw-in terminal cable 1…4 mm² | 1.7 Nm via screw-in terminal cable 1…4 mm² | 1.7 Nm via screw-in terminal cable 1…4 mm² | 1.7 Nm via screw-in terminal cable 1…4 mm² |
1.7 Nm via screw-in terminal cable 1…6 mm² | 1.7 Nm via screw-in terminal cable 1…6 mm² | 1.7 Nm via screw-in terminal cable 1…6 mm² | 1.7 Nm via screw-in terminal cable 1…6 mm² | |
1.7 Nm via screw-in terminal cable 1.5…6 mm² | 1.7 Nm via screw-in terminal cable 1.5…6 mm² | 1.7 Nm via screw-in terminal cable 1.5…6 mm² | 1.7 Nm via screw-in terminal cable 1.5…6 mm² | |
Breaking capacity | Icu: >= 100 kA at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 | Icu: >= 100 kA at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 | Icu: >= 100 kA at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 | Icu: >= 100 kA at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 |
Icu: >= 100 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 | Icu: >= 100 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 | Icu: >= 100 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 | Icu: >= 100 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 | |
Icu: >= 100 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 | Icu: >= 100 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 | Icu: >= 100 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 | Icu: 50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 | |
Icu: >= 100 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 | Icu: >= 100 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 | Icu: >= 100 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 | Icu: 50 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 | |
Icu: >= 100 kA at 690 V AC 50/60 Hz conforming to IEC 60947-2 | Icu: 3 kA at 690 V AC 50/ 60 Hz conforming to IEC 60947-2 | Icu: 3 kA at 690 V AC 50/ 60 Hz conforming to IEC 60947-2 | Icu: 3 kA at 690 V AC 50/60 Hz conforming to IEC 60947-2 | |
Rated operating short-circuit breaking capacity [Ics] | 75 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 | 75 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 | 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 | |
100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 | ||||
75 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 2 | ||||
high | 89mm | 89mm | 89 mm | 89mm |
width | 44.5 mm | 44.5 mm | 44.5 mm | 44.5 mm |
depth | 78.2 mm | 78.2 mm | 78.2 mm | 78.2 mm |
product weight | 0.26kg | 0.26kg | 0.26kg | 0.26kg |
Environment | ||||
Standards compliant | GB 14048.4 | GB 14048.4 | GB 14048.4 | GB 14048.4 |
IEC 60947-1 | IEC 60947-1 | IEC 60947-1 | IEC 60947-1 | |
IEC 60947-2 | IEC 60947-2 | IEC 60947-2 | IEC 60947-2 | |
IEC 60947-4-1 | IEC 60947-4-1 | IEC 60947-4-1 | IEC 60947-4-1 | |
certified product | CCC | CCC | CCC | CCC |
CE | UKCA | UKCA | UKCA | |
UKCA | CE | CE | CE | |
Protective measures | TH | TH | TH | TH |
IP protection class | IP20 complies with screwed (body) | IP20 complies with screwed (body) | IP20 complies with screwed (body) | IP20 complies with screwed (body) |
Shock and vibration resistance | Shock resistance 11 ms (30 gn) conforming to IEC 60068-2-27 | Shock resistance 11 ms (30 gn) conforming to IEC 60068-2-27 | Shock resistance 11 ms (30 gn) conforming to IEC 60068-2-27 | Shock resistance 11 ms (30 gn) conforming to IEC 60068-2-27 |
Shock resistance (5 gn (5…150 Hz)) conforming to IEC 60068-2-6 | Shock resistance (5 gn (5…150 Hz)) conforming to IEC 60068-2-6 | Shock resistance (5 gn (5…150 Hz)) conforming to IEC 60068-2-6 | Shock resistance (5 gn (5…150 Hz)) conforming to IEC 60068-2-6 | |
ambient temperature | -20…40 °C In cabinet | -20…40 °C In cabinet | -20…40 °C In cabinet | -20…40 °C In cabinet |
-20…60 °C Body | -20…60 °C Body | -20…60 °C Body | -20…60 °C Body | |
storage environment temperature | -40…80°C | -40…80°C | -40…80°C | -40…80°C |
Fire resistance and abnormal high temperature resistance | 960 °C conforming to IEC 60695-2-1 | 960 °C conforming to IEC 60695-2-1 | 960 °C conforming to IEC 60695-2-1 | 960 °C conforming to IEC 60695-2-1 |
working altitude | <= 2000m | <= 2000m | <= 2000m | <= 2000m |
Packaging unit | ||||
Unit Type of Package 1 | PCE | PCE | PCE | PCE |
Number of Units in Package 1 | 1 | 1 | 1 | 1 |
Package 1 Height | 4.716 cm | 4.869 cm | 4.799 cm | 4.94cm |
Package 1 Width | 8.214 cm | 8.195 cm | 8.242 cm | 8.13cm |
Package 1 Length | 9.056 cm | 9.019 cm | 9.08 cm | 9.02 cm |
Package 1 Weight | 229.0g | 258.0g | 258.0g | 271.875g |
Unit Type of Package 2 | S02 | S02 | S02 | S02 |
Number of Units in Package 2 | 32 | 32 | 32 | 32 |
Package 2 Height | 15.0cm | 15.0cm | 15.0cm | 15.0cm |
Package 2 Width | 30.0cm | 30.0cm | 30.0cm | 30.0cm |
Package 2 Length | 40.0cm | 40.0cm | 40.0cm | 40.0cm |
Package 2 Weight | 7.752kg | 8.608 kg | 8.648kg | 9.092kg |
Unit Type of Package 3 | P06 | P06 | P06 | P06 |
Number of Units in Package 3 | 640 | 640 | 640 | 640 |
Package 3 Height | 90.0cm | 90.0cm | 90.0cm | 90.0cm |
Package 3 Width | 60.0cm | 60.0cm | 60.0cm | 60.0cm |
Package 3 Length | 80.0cm | 80.0cm | 80.0cm | 80.0cm |
Package 3 Weight | 165.04kg | 182.16kg | 182.96kg | 191.84kg |
Contract warranty | ||||
Warranty | 18 months | 18 months | 18 months | 18 months |
Main information | ||||
Part Number | GV2ME14C | GV2ME16C | GV2ME20C | GV2ME22C |
Product Series | TeSys Deca | TeSys Deca | TeSys Deca | TeSys Deca |
product name | TeSys GV2 | TeSys GV2 | TeSys GV2 | TeSys GV2 |
product short name | GV2ME | GV2ME | GV2ME | GV2ME |
product type | Breaker | Breaker | Breaker | Breaker |
Applications | Motor protection | Motor protection | Motor protection | Motor protection |
number of poles | 3P | 3P | 3P | 3P |
Additional information | ||||
Grid type | AC | AC | AC | AC |
Network frequency | 50/60 Hz conforming to IEC 60947-2 | 50/60 Hz conforming to IEC 60947-2 | 50/60 Hz conforming to IEC 60947-2 | 50/60 Hz conforming to IEC 60947-2 |
control type | (Push) button | (Push) button | (Push) button | (Push) button |
installation method | Rail installation | Rail installation | Rail installation | Rail installation |
installation location | horizontal vertical | horizontal vertical | Vertical | Vertical |
horizontal direction | horizontal direction | |||
Motor power (kW) | 2.2 kW at 230 V AC 50/60 Hz | 3 kW at 230 V AC 50/60 Hz | 4 kW at 230 V AC 50/60 Hz | 5.5 kW at 230 V AC 50/60 Hz |
4 kW at 400 V | 5.5 kW at 400 V | 7.5 kW at 400 V | 11 kW at 400 V | |
4 kW at 415 V | 5.5 kW at 415 V | 9 kW at 415 V | 11 kW at 415 V | |
4 kW at 440 V AC 50/60 Hz | 7.5 kW at 440 V AC 50/60 Hz | 9 kW at 440 V AC 50/60 Hz | 11 kW at 440 V AC 50/60 Hz | |
Rated current [In] | 10A | 14A | 18A | 25A |
Trip unit type | Thermomagnetic | Thermomagnetic | Thermomagnetic | Thermomagnetic |
Electromagnetic trip current | 138A | 170A | 223A | 327A |
Thermal overload protection setting range | 6…10A | 9…14A | 13…18A | 20…25A |
isolation function | Applies to IEC 60947-1 § 7-1-6 | Applies to IEC 60947-1 § 7-1-6 | Applies to IEC 60947-1 § 7-1-6 | Applies to IEC 60947-1 § 7-1-6 |
Mechanical shock resistance | 0.5 J IK04 | 0.5 J IK04 | 0.5 J IK04 | 0.5 J IK04 |
phase loss sensitivity | Is compliant with IEC 60947-4-1 § 7-2-1-5-2 | Is compliant with IEC 60947-4-1 § 7-2-1-5-2 | Is compliant with IEC 60947-4-1 § 7-2-1-5-2 | Is compliant with IEC 60947-4-1 § 7-2-1-5-2 |
use category | Type AC conforms to IEC 60947-2 | Type AC conforms to IEC 60947-2 | Type AC conforms to IEC 60947-2 | Type AC conforms to IEC 60947-2 |
AC-3 conforms to IEC 60947-4-1 | AC-3 conforms to IEC 60947-4-1 | AC-3 conforms to IEC 60947-4-1 | AC-3 conforms to IEC 60947-4-1 | |
Rated working voltage [Ue] | 690 V AC 50/60 Hz conforming to IEC 60947-2 | 690 V AC 50/60 Hz conforming to IEC 60947-2 | 690 V AC 50/60 Hz conforming to IEC 60947-2 | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
Rated insulation voltage [Ui] | 690 V AC 50/60 Hz conforming to IEC 60947-2 | 690 V AC 50/60 Hz conforming to IEC 60947-2 | 690 V AC 50/60 Hz conforming to IEC 60947-2 | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
600 V AC 50/60 Hz conforming to UL 508 | 600 V AC 50/60 Hz conforming to UL 508 | 600 V AC 50/60 Hz conforming to UL 508 | 600 V AC 50/60 Hz conforming to UL 508 | |
600 V AC 50/60 Hz conforming to CSA C22.2 No 14 | 600 V AC 50/60 Hz conforming to CSA C22.2 No 14 | 600 V AC 50/60 Hz conforming to CSA C22.2 No 14 | 600 V AC 50/60 Hz conforming to CSA C22.2 No 14 | |
Rated impulse withstand voltage [Uimp] | 6 kV according to IEC 947-2 | 6 kV according to IEC 947-2 | 6 kV according to IEC 947-2 | 6 kV according to IEC 947-2 |
power consumption per pole | 2.5W | 2.5W | 2.5W | 2.5W |
Mechanical life | 100000 times | 100000 times | 100000 times | 100000 times |
Electrical life | 100000 cycles for AC-3 at 440 V In | 100000 cycles for AC-3 at 440 V In | 100000 cycles for AC-3 at 440 V In | 100000 cycles for AC-3 at 440 V In |
100000 cycles for AC-3 at 440 V In/2 | 100000 cycles for AC-3 at 440 V In/2 | 100000 cycles for AC-3 at 440 V In/2 | 100000 cycles for AC-3 at 440 V In/2 | |
maximum conversions | 25 cyc/h | 25 cyc/h | 25 cyc/h | 25 cyc/h |
specified load | Continuous according to IEC 60947-4-1 | Continuous according to IEC 60947-4-1 | Continuous according to IEC 60947-4-1 | Continuous according to IEC 60947-4-1 |
Wiring capacity | Power circuit: Screw-in terminals 2 1…6 mm² Cable option: Solid without wire terminals Power circuit: | Power circuit: Screw-in terminals 2 1…6 mm² Cable option: Solid without wire terminals Power circuit: | Power circuit: Screw-in terminals 2 1…6 mm² Cable option: Solid without wire terminals Power circuit: | Power circuit: Screw-in terminals 2 1…6 mm² Cable option: Solid without wire terminals Power circuit: |
Screw-in terminals 2 1.5…6 mm² Cable option: Flexible without wire terminals | Screw-in terminals 2 1.5…6 mm² Cable option: Flexible without wire terminals | Screw-in terminals 2 1.5…6 mm² Cable option: Flexible without wire terminals | Screw-in terminals 2 1.5…6 mm² Cable option: Flexible without wire terminals | |
Power circuit: Screw-in terminals 2 1…4 mm² Cable selection: Flexible with cable terminals | Power circuit: Screw-in terminals 2 1…4 mm² Cable selection: Flexible with wire terminals | Power circuit: Screw-in terminals 2 1…4 mm² Cable selection: Flexible with cable terminals | Power circuit: Screw-in terminals 2 1…4 mm² Cable selection: Flexible with cable terminals | |
Tightening torque | 1.7 Nm via screw-in terminal cable 1…4 mm² | 1.7 Nm via screw-in terminal cable 1…4 mm² | 1.7 Nm via screw-in terminal cable 1…4 mm² | 1.7 Nm via screw-in terminal cable 1…4 mm² |
1.7 Nm via screw-in terminal cable 1…6 mm² | 1.7 Nm via screw-in terminal cable 1…6 mm² | 1.7 Nm via screw-in terminal cable 1…6 mm² | 1.7 Nm via screw-in terminal cable 1…6 mm² | |
1.7 Nm via screw-in terminal cable 1.5…6 mm² | 1.7 Nm via screw-in terminal cable 1.5…6 mm² | 1.7 Nm via screw-in terminal cable 1.5…6 mm² | 1.7 Nm via screw-in terminal cable 1.5…6 mm² | |
Breaking capacity | Icu: >= 100 kA at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 | Icu: >= 100 kA at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 | Icu: >= 100 kA at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 | Icu: 50 kA at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 |
Icu: >= 100 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 | Icu: 15 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 | Icu: 15 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 | Icu: 15 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 | |
Icu: 15 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 | Icu: 8 kA at… at 440 V AC 50/60 Hz conforming to IEC 60947-2 | Icu: 8 kA at… at 440 V AC 50/60 Hz conforming to IEC 60947-2 | Icu: 6 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 | |
Icu: 10 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 | Icu: 6 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 | Icu: 6 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 | Icu: 4 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 | |
Icu: 3 kA at 690 V AC 50/60 Hz conforming to IEC 60947-2 | Icu: 3 kA at 690 V AC 50/60 Hz conforming to IEC 60947- 2 | Icu: 3 kA at 690 V AC 50/60 Hz conforming to IEC 60947- 2 | Icu: 3 kA at 690 V AC 50/60 Hz conforming to IEC 60947-2 | |
Rated operating short-circuit breaking capacity [Ics] | 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 | 50 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 | 50 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 | 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 |
100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 | 50 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 | 50 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 | 40 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 | |
75 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 2 | 75 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 | 75 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 | 50 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 | |
75 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 | 75 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 | 75 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 | ||
75 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 | ||||
high | 89mm | 89mm | 89mm | 89 mm |
width | 44.5 mm | 44.5 mm | 44.5 mm | 44.5 mm |
depth | 78.2 mm | 78.2 mm | 78.2 mm | 78.2 mm |
product weight | 0.26kg | 0.26kg | 0.26kg | 0.26kg |
Environment | ||||
Standards compliant | GB 14048.4 | GB 14048.4 | GB 14048.4 | GB 14048.4 |
IEC 60947-1 | IEC 60947-1 | IEC 60947-1 | IEC 60947-1 | |
IEC 60947-2 | IEC 60947-2 | IEC 60947-2 | IEC 60947-2 | |
IEC 60947-4-1 | IEC 60947-4-1 | IEC 60947-4-1 | IEC 60947-4-1 | |
certified product | CCC | CCC | CCC | CCC |
UKCA | UKCA | UKCA | UKCA | |
CE | CE | CE | CE | |
Protective measures | TH | TH | TH | TH |
IP protection class | IP20 complies with screwed (body) | IP20 complies with screwed (body) | IP20 complies with screwed (body) | IP20 complies with screwed (body) |
Shock and vibration resistance | Shock resistance 11 ms (30 gn) conforming to IEC 60068-2-27 | Shock resistance 11 ms (30 gn) conforming to IEC 60068-2-27 | Shock resistance 11 ms (30 gn) conforming to IEC 60068-2-27 | Shock resistance 11 ms (30 gn) conforming to IEC 60068-2-27 |
Shock resistance (5 gn (5…150 Hz)) conforming to IEC 60068-2-6 | Shock resistance (5 gn (5…150 Hz)) conforming to IEC 60068-2-6 | Shock resistance (5 gn (5…150 Hz)) conforming to IEC 60068-2-6 | Shock resistance (5 gn (5…150 Hz)) conforming to IEC 60068-2-6 | |
ambient temperature | -20…40 °C In cabinet | -20…40 °C In cabinet | -20…40 °C In cabinet | -20…40 °C In cabinet |
-20…60 °C Body | -20…60 °C Body | -20…60 °C Body | -20…60 °C Body | |
storage environment temperature | -40…80°C | -40…80°C | -40…80°C | -40…80°C |
Fire resistance and abnormal high temperature resistance | 960 °C conforming to IEC 60695-2-1 | 960 °C conforming to IEC 60695-2-1 | 960 °C conforming to IEC 60695-2-1 | 960 °C conforming to IEC 60695-2-1 |
working altitude | <= 2000m | <= 2000m | <= 2000m | <= 2000m |
Packaging unit | ||||
Unit Type of Package 1 | PCE | PCE | PCE | PCE |
Number of Units in Package 1 | 1 | 1 | 1 | 1 |
Package 1 Height | 4.87cm | 5.3 cm | 4.78cm | 4.88cm |
Package 1 Width | 8.18cm | 9.0cm | 8.18cm | 8.09cm |
Package 1 Length | 9.0cm | 9.6cm | 9.03 cm | 9.02 cm |
Package 1 Weight | 272.01g | 278.28g | 284.625g | 284.843g |
Unit Type of Package 2 | S02 | S02 | S02 | S02 |
Number of Units in Package 2 | 32 | 32 | 32 | 32 |
Package 2 Height | 15.0cm | 15.0cm | 15.0cm | 15.0cm |
Package 2 Width | 30.0cm | 30.0cm | 30.0cm | 30.0cm |
Package 2 Length | 40.0cm | 40.0cm | 40.0cm | 40.0cm |
Package 2 Weight | 9.079kg | 9.297 kg | 9.5kg | 9.507 kg |
Unit Type of Package 3 | P06 | P06 | P06 | P06 |
Number of Units in Package 3 | 640 | 640 | 640 | 640 |
Package 3 Height | 90.0cm | 90.0cm | 90.0cm | 90.0cm |
Package 3 Width | 60.0cm | 60.0cm | 60.0cm | 60.0cm |
Package 3 Length | 80.0cm | 80.0cm | 80.0cm | 80.0cm |
Package 3 Weight | 191.58kg | 195.94kg | 200.0kg | 200.14kg |
Contract warranty | ||||
Warranty | 18 months | 18 months | 18 months | 18 months |
Main information | |
Part Number | GV2ME32C |
Product Series | TeSys Deca |
product name | TeSys GV2 |
product short name | GV2ME |
product type | Breaker |
Applications | Motor protection |
number of poles | 3P |
Additional information | |
Grid type | AC |
Network frequency | 50/60 Hz conforming to IEC 60947-2 |
control type | (Push) button |
installation method | Rail installation |
installation location | horizontal vertical |
Motor power (kW) | 7.5 kW at 230 V AC 50/60 Hz |
15 kW at 400 V | |
15 kW at 415 V | |
15 kW at 440 V AC 50/60 Hz | |
Rated current [In] | 32A |
Trip unit type | Thermomagnetic |
Electromagnetic trip current | 416A |
Thermal overload protection setting range | 24…32A |
isolation function | Applies to IEC 60947-1 § 7-1-6 |
Mechanical shock resistance | 0.5 J IK04 |
phase loss sensitivity | Is compliant with IEC 60947-4-1 § 7-2-1-5-2 |
use category | Type AC conforms to IEC 60947-2 |
AC-3 conforms to IEC 60947-4-1 | |
Rated working voltage [Ue] | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
Rated insulation voltage [Ui] | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
600 V AC 50/60 Hz conforming to UL 508 | |
600 V AC 50/60 Hz conforming to CSA C22.2 No 14 | |
Rated impulse withstand voltage [Uimp] | 6 kV according to IEC 947-2 |
power consumption per pole | 2.5W |
Mechanical life | 100000 times |
Electrical life | 100000 cycles for AC-3 at 440 V In |
100000 cycles for AC-3 at 440 V In/2 | |
maximum conversions | 25 cyc/h |
specified load | Continuous according to IEC 60947-4-1 |
Wiring capacity | Power circuit: Screw-in terminals 2 1…6 mm² Cable option: Solid without wire terminals Power circuit: |
Screw-in terminals 2 1.5…6 mm² Cable option: Flexible without wire terminals | |
Power circuit: Screw-in terminals 2 1…4 mm² Cable selection: Flexible with wire terminals | |
Tightening torque | 1.7 Nm via screw-in terminal cable 1…4 mm² |
1.7 Nm via screw-in terminal cable 1…6 mm² | |
1.7 Nm via screw-in terminal cable 1.5…6 mm² | |
Breaking capacity | Icu: 50 kA at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 |
Icu: 10 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 | |
Icu: 6 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 | |
Icu: 4 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 | |
Icu: 3 kA at 690 V AC 50/60 Hz conforming to IEC 60947-2 | |
Rated operating short-circuit breaking capacity [Ics] | 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 |
50 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 | |
50 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 | |
75 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 | |
75 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 | |
high | 89mm |
width | 44.5 mm |
depth | 78.2 mm |
product weight | 0.26kg |
Environment | |
Standards compliant | GB 14048.4 |
IEC 60947-1 | |
IEC 60947-2 | |
IEC 60947-4-1 | |
certified product | CCC |
UKCA | |
CE | |
Protective measures | TH |
IP protection class | IP20 complies with screwed (body) |
Shock and vibration resistance | Shock resistance 11 ms (30 gn) conforming to IEC 60068-2-27 |
Shock resistance (5 gn (5…150 Hz)) conforming to IEC 60068-2-6 | |
ambient temperature | -20…40 °C In cabinet |
-20…60 °C Body | |
storage environment temperature | -40…80°C |
Fire resistance and abnormal high temperature resistance | 960 °C conforming to IEC 60695-2-1 |
working altitude | <= 2000m |
Packaging unit | |
Unit Type of Package 1 | PCE |
Number of Units in Package 1 | 1 |
Package 1 Height | 4.78cm |
Package 1 Width | 8.15cm |
Package 1 Length | 9.03 cm |
Package 1 Weight | 279.6g |
Unit Type of Package 2 | S02 |
Number of Units in Package 2 | 32 |
Package 2 Height | 15.0cm |
Package 2 Width | 30.0cm |
Package 2 Length | 40.0cm |
Package 2 Weight | 9.339 kg |
Unit Type of Package 3 | P06 |
Number of Units in Package 3 | 640 |
Package 3 Height | 90.0cm |
Package 3 Width | 60.0cm |
Package 3 Length | 80.0cm |
Package 3 Weight | 196.784kg |
Contract warranty | |
Warranty | 18 months |
INOSAKI Limited
RM B 5/F Gaylord Comm,
Bldg 114-118 Lockhart Rd.
Hong Kong
INOSAKI Sdn. Bhd.
2-1-9, Ground Floor, One Square, Tingkat Mahsuri 1,
11900 Bayan Lepas, Penan
INOSAKI Pte. Ltd.
101 Upper Cross Street,
No. 06-17, People’s Park Centre,
Singapore (058357)