Specifications

Main information
Part Number GV2ME01C GV2ME02C GV2ME03C GV2ME04C
Product Series TeSys Deca TeSys Deca TeSys Deca TeSys Deca
product name TeSys GV2 TeSys GV2 TeSys GV2 TeSys GV2
product short name GV2ME GV2ME GV2ME GV2ME
product type Breaker Breaker Breaker Breaker
Applications Motor protection Motor protection Motor protection Motor protection
number of poles 3P 3P 3P 3P
Additional information
Grid type AC AC AC AC
Network frequency 50/60 Hz conforming to IEC 60947-2 50/60 Hz conforming to IEC 60947-2 50/60 Hz conforming to IEC 60947-2 50/60 Hz conforming to IEC 60947-2
control type (Push) button (Push) button (Push) button (Push) button
installation method Rail installation Rail installation Rail installation Rail installation
Vertical Vertical
installation location horizontal vertical horizontal direction horizontal direction horizontal vertical
Motor power (kW) 0.00…0.37 kW at 230 V AC 50/60 Hz 0.00…0.37 kW at 230 V AC 50/60 Hz 0.00…0.37 kW at 230 V AC 50/60 Hz 0.00…0.37 kW at 230 V AC 50/60 Hz
0.00…0.37 kW at 400 V AC 50/60 Hz 0.00…0.37 kW at 400 V AC 50/60 Hz 0.00…0.37 kW at 400 V AC 50/60 Hz 0.00…0.37 kW at 400 V AC 50/60 Hz
0.00…0.37 kW at 415 V AC 50/60 Hz 0.00…0.37 kW at 415 V AC 50/60 Hz 0.00…0.37 kW at 415 V AC 50/60 Hz 0.00…0.37 kW at 415 V AC 50/60 Hz
0.00…0.37 kW at 440 V AC 50/60 Hz 0.00…0.37 kW at 440 V AC 50/60 Hz 0.00…0.37 kW at 440 V AC 50/60 Hz 0.00…0.37 kW at 440 V AC 50/60 Hz
Rated current [In] 1.6A 1.6A 1.6A 1.6A
Trip unit type Thermomagnetic Thermomagnetic Thermomagnetic Thermomagnetic
Electromagnetic trip current 1.5A 2.4A 5A 8A
Thermal overload protection setting range 0.1…0.16A 0.16…0.25 A 0.25…0.4 A 0.4…0.63A
isolation function Applies to IEC 60947-1 § 7-1-6 Applies to IEC 60947-1 § 7-1-6 Applies to IEC 60947-1 § 7-1-6 Applies to IEC 60947-1 § 7-1-6
Mechanical shock resistance 0.5 J IK04 0.5 J IK04 0.5 J IK04 0.5 J IK04
phase loss sensitivity Is compliant with IEC 60947-4-1 § 7-2-1-5-2 Is compliant with IEC 60947-4-1 § 7-2-1-5-2 Is compliant with IEC 60947-4-1 § 7-2-1-5-2 Is compliant with IEC 60947-4-1 § 7-2-1-5-2
use category Type AC conforms to IEC 60947-2 Type AC conforms to IEC 60947-2 Type AC conforms to IEC 60947-2 Type AC conforms to IEC 60947-2
AC-3 conforms to IEC 60947-4-1 AC-3 conforms to IEC 60947-4-1 AC-3 conforms to IEC 60947-4-1 AC-3 conforms to IEC 60947-4-1
Rated working voltage [Ue] 690 V AC 50/60 Hz conforming to IEC 60947-2 690 V AC 50/60 Hz conforming to IEC 60947-2 690 V AC 50/60 Hz conforming to IEC 60947-2 690 V AC 50/60 Hz conforming to IEC 60947-2
Rated insulation voltage [Ui] 690 V AC 50/60 Hz conforming to IEC 60947-2 690 V AC 50/60 Hz conforming to IEC 60947-2 690 V AC 50/60 Hz conforming to IEC 60947-2 690 V AC 50/60 Hz conforming to IEC 60947-2
600 V AC 50/60 Hz conforming to UL 508 600 V AC 50/60 Hz conforming to UL 508 600 V AC 50/60 Hz conforming to UL 508 600 V AC 50/60 Hz conforming to UL 508
600 V AC 50/60 Hz conforming to CSA C22.2 No 14 600 V AC 50/60 Hz conforming to CSA C22.2 No 14 600 V AC 50/60 Hz conforming to CSA C22.2 No 14 600 V AC 50/60 Hz conforming to CSA C22.2 No 14
Rated impulse withstand voltage [Uimp] 6 kV according to IEC 947-2 6 kV according to IEC 947-2 6 kV according to IEC 947-2 6 kV according to IEC 947-2
power consumption per pole 2.5W 2.5W 2.5W 2.5W
Mechanical life 100000 times 100000 times 100000 times 100000 times
Electrical life 100000 cycles for AC-3 at 440 V In 100000 cycles for AC-3 at 440 V In 100000 cycles for AC-3 at 440 V In 100000 cycles for AC-3 at 440 V In
100000 cycles for AC-3 at 440 V In/2 100000 cycles for AC-3 at 440 V In/2 100000 cycles for AC-3 at 440 V In/2 100000 cycles for AC-3 at 440 V In/2
maximum conversions 25 cyc/h 25 cyc/h 25 cyc/h 25 cyc/h
specified load Continuous according to IEC 60947-4-1 Continuous according to IEC 60947-4-1 Continuous according to IEC 60947-4-1 Continuous according to IEC 60947-4-1
Wiring capacity Power circuit: Screw-in terminals 2 1…6 mm² Cable option: Solid without wire terminals Power circuit: Power circuit: Screw-in terminals 2 1…6 mm² Cable option: Solid without wire terminals Power circuit: Power circuit: Screw-in terminals 2 1…6 mm² Cable option: Solid without wire terminals Power circuit: Power circuit: Screw-in terminals 2 1…6 mm² Cable option: Solid without wire terminals Power circuit:
Screw-in terminals 2 1.5…6 mm² Cable option: Flexible without wire terminals Screw-in terminals 2 1.5…6 mm² Cable option: Flexible without wire terminals Screw-in terminals 2 1.5…6 mm² Cable option: Flexible without wire terminals Screw-in terminals 2 1.5…6 mm² Cable option: Flexible without wire terminals
Power circuit: Screw-in terminals 2 1…4 mm² Cable selection: Flexible with cable terminals Power circuit: Screw-in terminals 2 1…4 mm² Cable selection: Flexible with wire terminals Power circuit: Screw-in terminals 2 1…4 mm² Cable selection: Flexible with wire terminals Power circuit: Screw-in terminals 2 1…4 mm² Cable selection: Flexible with wire terminals
Tightening torque 1.7 Nm via screw-in terminal cable 1…4 mm² 1.7 Nm via screw-in terminal cable 1…4 mm² 1.7 Nm via screw-in terminal cable 1…4 mm² 1.7 Nm via screw-in terminal cable 1…4 mm²
1.7 Nm via screw-in terminal cable 1…6 mm² 1.7 Nm via screw-in terminal cable 1…6 mm² 1.7 Nm via screw-in terminal cable 1…6 mm² 1.7 Nm via screw-in terminal cable 1…6 mm²
1.7 Nm via screw-in terminal cable 1.5…6 mm² 1.7 Nm via screw-in terminal cable 1.5…6 mm² 1.7 Nm via screw-in terminal cable 1.5…6 mm² 1.7 Nm via screw-in terminal cable 1.5…6 mm²
Breaking capacity Icu: >= 100 kA at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 Icu: >= 100 kA at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 Icu: >= 100 kA at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 Icu: >= 100 kA at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
Icu: >= 100 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 Icu: >= 100 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 Icu: >= 100 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 Icu: >= 100 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
Icu: >= 100 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 Icu: >= 100 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 Icu: >= 100 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 Icu: >= 100 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
Icu: >= 100 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 Icu: >= 100 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 Icu: >= 100 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 Icu: >= 100 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
Icu: >= 100 kA at 690 V AC 50/60 Hz conforming to IEC 60947-2 Icu: >= 100 kA at 690 V AC 50/60 Hz conforming to IEC 60947-2 Icu: >= 100 kA at 690 V AC 50/60 Hz conforming to IEC 60947-2 Icu: >= 100 kA at 690 V AC 50/60 Hz conforming to IEC 60947-2
high 89 mm 89mm 89 mm 89mm
width 44.5 mm 44.5 mm 44.5 mm 44.5 mm
depth 78.2 mm 78.2 mm 78.2 mm 78.2 mm
product weight 0.26kg 0.26kg 0.26kg 0.26kg
Environment
Standards compliant GB 14048.4 GB 14048.4 GB 14048.4 GB 14048.4
IEC 60947-1 IEC 60947-1 IEC 60947-1 IEC 60947-1
IEC 60947-2 IEC 60947-2 IEC 60947-2 IEC 60947-2
IEC 60947-4-1 IEC 60947-4-1 IEC 60947-4-1 IEC 60947-4-1
certified product CCC CCC CCC CCC
CE CE CE CE
UKCA UKCA UKCA UKCA
Protective measures TH TH TH TH
IP protection class IP20 complies with screwed (body) IP20 complies with screwed (body) IP20 complies with screwed (body) IP20 complies with screwed (body)
Shock and vibration resistance Shock resistance 11 ms (30 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms (30 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms (30 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms (30 gn) conforming to IEC 60068-2-27
Shock resistance (5 gn (5…150 Hz)) conforming to IEC 60068-2-6 Shock resistance (5 gn (5…150 Hz)) conforming to IEC 60068-2-6 Shock resistance (5 gn (5…150 Hz)) conforming to IEC 60068-2-6 Shock resistance (5 gn (5…150 Hz)) conforming to IEC 60068-2-6
ambient temperature -20…40 °C In cabinet -20…40 °C In cabinet -20…40 °C In cabinet -20…40 °C In cabinet
-20…60 °C Body -20…60 °C Body -20…60 °C Body -20…60 °C Body
storage environment temperature -40…80°C -40…80°C -40…80°C -40…80°C
Fire resistance and abnormal high temperature resistance 960 °C conforming to IEC 60695-2-1 960 °C conforming to IEC 60695-2-1 960 °C conforming to IEC 60695-2-1 960 °C conforming to IEC 60695-2-1
working altitude <= 2000m <= 2000m <= 2000m <= 2000m
Packaging unit
Unit Type of Package 1 PCE PCE PCE PCE
Number of Units in Package 1 1 1 1 1
Package 1 Height 5.141 cm 5.168 cm 4.991 cm 4.855 cm
Package 1 Width 8.315 cm 8.262 cm 8.323 cm 8.012 cm
Package 1 Length 9.129 cm 9.135 cm 9.183 cm 8.933 cm
Package 1 Weight 220.0g 220.0g 220.0g 231.1g
Unit Type of Package 2 S02 S02 S02 S02
Number of Units in Package 2 32 32 32 32
Package 2 Height 15.0cm 15.0cm 15.0cm 15.0cm
Package 2 Width 30.0cm 30.0cm 30.0cm 30.0cm
Package 2 Length 40.0cm 40.0cm 40.0cm 40.0cm
Package 2 Weight 7.74kg 7.711kg 7.66 kg 7.787 kg
Unit Type of Package 3 P06 P06 P06 P06
Number of Units in Package 3 640 640 640 640
Package 3 Height 90.0cm 90.0cm 90.0cm 90.0cm
Package 3 Width 60.0cm 60.0cm 60.0cm 60.0cm
Package 3 Length 80.0cm 80.0cm 80.0cm 80.0cm
Package 3 Weight 164.8kg 164.22kg 163.2kg 165.744 kg
Contract warranty
Warranty 18 months 18 months 18 months 18 months

 

 

Main information
Part Number GV2ME06C
Product Series TeSys Deca
product name TeSys GV2
product short name GV2ME
product type Breaker
Applications Motor protection
number of poles 3P
Additional information
Grid type AC
Network frequency 50/60 Hz conforming to IEC 60947-2
control type (Push) button
installation method Rail installation
installation location Vertical
horizontal direction
Motor power (kW) 0.00…0.37 kW at 230 V AC 50/60 Hz
0.37 kW at 400 V AC 50/60 Hz
0.00…0.37 kW at 415 V AC 50/60 Hz
0.55 kW at 440 V AC 50/60 Hz 60Hz
Rated current [In] 1.6A
Trip unit type Thermomagnetic
Electromagnetic trip current 22.5A
Thermal overload protection setting range 1…1.6A
isolation function Applies to IEC 60947-1 § 7-1-6
Mechanical shock resistance 0.5 J IK04
phase loss sensitivity Is compliant with IEC 60947-4-1 § 7-2-1-5-2
use category Type AC conforms to IEC 60947-2
AC-3 conforms to IEC 60947-4-1
Rated working voltage [Ue] 690 V AC 50/60 Hz conforming to IEC 60947-2
Rated insulation voltage [Ui] 690 V AC 50/60 Hz conforming to IEC 60947-2
600 V AC 50/60 Hz conforming to UL 508
600 V AC 50/60 Hz conforming to CSA C22.2 No 14
Rated impulse withstand voltage [Uimp] 6 kV according to IEC 947-2
power consumption per pole 2.5W
Mechanical life 100000 times
Electrical life 100000 cycles for AC-3 at 440 V In
100000 cycles for AC-3 at 440 V In/2
maximum conversions 25 cyc/h
specified load Continuous according to IEC 60947-4-1
Wiring capacity Power circuit: Screw-in terminals 2 1…6 mm² Cable option: Solid without wire terminals Power circuit:
Screw-in terminals 2 1.5…6 mm² Cable option: Flexible without wire terminals
Power circuit: Screw-in terminals 2 1…4 mm² Cable selection: Flexible with cable terminals
Tightening torque 1.7 Nm via screw-in terminal cable 1…4 mm²
1.7 Nm via screw-in terminal cable 1…6 mm²
1.7 Nm via screw-in terminal cable 1.5…6 mm²
Breaking capacity Icu: >= 100 kA at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
Icu: >= 100 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
Icu: >= 100 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
Icu: >= 100 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
Icu: >= 100 kA at 690 V AC 50/60 Hz conforming to IEC 60947-2
high 89 mm
width 44.5 mm
depth 78.2 mm
product weight 0.26kg
Environment
Standards compliant GB 14048.4
IEC 60947-1
IEC 60947-2
IEC 60947-4-1
certified product CCC
UKCA
CE
Protective measures TH
IP protection class IP20 complies with screwed (body)
Shock and vibration resistance Shock resistance 11 ms (30 gn) conforming to IEC 60068-2-27
Shock resistance (5 gn (5…150 Hz)) conforming to IEC 60068-2-6
ambient temperature -20…40 °C In cabinet
-20…60 °C Body
storage environment temperature -40…80°C
Fire resistance and abnormal high temperature resistance 960 °C conforming to IEC 60695-2-1
working altitude <= 2000m
Packaging unit
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 5.4 cm
Package 1 Width 8.3 cm
Package 1 Length 9.6cm
Package 1 Weight 251.0g
Unit Type of Package 2 S02
Number of Units in Package 2 32
Package 2 Height 15.0cm
Package 2 Width 30.0cm
Package 2 Length 40.0cm
Package 2 Weight 8.379 kg
Unit Type of Package 3 P06
Number of Units in Package 3 640
Package 3 Height 90.0cm
Package 3 Width 60.0cm
Package 3 Length 80.0cm
Package 3 Weight 177.58kg
Contract warranty
Warranty 18 months

Additional information

Weight N/A
Dimensions N/A
Model

, , , ,

Related Products

SICK_Inductive Proximity Sensors_IME12-02BNSZC0S
SICK_sensor_Photoelectric_sensor_W100-2_WS WE100-2N3439
SICK_sensor_Photoelectric_sensor_W12-2 Laser_WT12L-2B551
Omron_Switch Mode Power Supply_S8FS-C10005J
PEPPERL+FUCHS_Diffuse Mode Sensors_ML100-8-W-200-RT-103-115
BX15M-TFR-T
Select your currency