DME5000-213 Long range distance sensors – SICK Sensor
$ 9,456.70
SKU: SICK 1025250
SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.
Part Number: 1025250
Distance Sensor Model: DME5000-213
OEM Spec Ref
Mechanics/electronics
Supply voltage Vs | DC 18 V … 30 V, limit values |
Ripple | < 5 Vpp 1) |
Initialization time | 1.5 s 2) |
Housing material | Metal (zinc diecast) |
Window material | Glass |
Connection type | Male connector, M16, 8-pin |
Indication | Display |
Weight | Approx. 1,650 g |
Current consumption | At 24 V DC < 250 mA |
Dimensions (W x H x D) | 61 mm x 101 mm x 176 mm |
Enclosure rating | IP65 |
Protection class | II 3) |
- 1) May not fall short of or exceed VS tolerances.
- 2) After loss of reflector < 1 s at max. speed Vmax < 1 m/s.
- 3) Reference voltage DC 32 V.
Performance
Measuring range | 0.15 m … 150 m, on “diamond grade” reflective tape 1) |
Target | Reflector |
Resolution | 0.05 mm … 5 mm |
Repeatability | 1 mm 1) 2) |
Accuracy | ± 3 mm |
Response time | 6 ms |
Output time | 2 ms |
Light source | Laser, red 3) visible red light |
Laser class | 2, complies with 21 CFR 1040.10 and 1040.11 except for the conformance according to “Laser Notice No. 50” from June 24, 2007 (IEC 60825-1:2014, EN 60825-1:2014) |
Typ. light spot size (distance) | 130 mm (at 70 m)
270 mm (at 150 m) 360 mm (at 220 m) |
Max. movement speed | 10 m/s |
- 1) On “diamond grade” reflective tape.
- 2) Statistical error 1 σ, environmental conditions constant, min. warm-up time 10 min.
- 3) Average service life of 50,000 h at TA = +25 °C.
Interfaces
|
|||||||||
|
|||||||||
Multifunctional input (MF) | 1 x MF 3) 4) |
- 1) Max. 100 nF/20 mH.
- 2) HIGH = > VS – 3 V / LOW = < 2 V.
- 3) HIGH = > 12 V / LOW = < 3 V.
- 4) Not reverse-polarity protected.
Ambient data
Electromagnetic compatibility (EMC) | EN 61000-6-2, EN 55011 |
Ambient temperature, operation | –10 °C … +55 °C
–10 °C … +75 °C, operation with cooling case |
Ambient temperature, storage | –25 °C … +75 °C |
Effect of air pressure | 0.3 ppm/hPa |
Effect of air temperature | 1 ppm/K |
Temperature drift | Typ. 0.1 mm/K |
Typ. Ambient light immunity | ≤ 40,000 lx |
Mechanical load | Shock: (EN 600 68-2-27 / –2-29)
Sine: (EN 600 68-2-6) Noise: (EN 600 68-2-64) |