DME4000-212 Long range distance sensors – SICK Sensor

USD $ 6,838.86

SKU: SICK 1029791

SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.

Part Number: 1029791
Distance Sensor Model: DME4000-212
OEM Spec Ref 

Mechanics/electronics

Supply voltage Vs DC 18 V … 30 V, limit values
Ripple < 5 Vpp 1)
Initialization time 1.5 s 2)
Housing material Metal (zinc diecast)
Window material Glass
Connection type Male connector, 2 x M12, 5-pin, B-coded, 1 x M16, 8-pin, B-coded
Indication Display
Weight Approx. 1,650 g
Current consumption At 24 V DC < 250 mA
Dimensions (W x H x D) 61 mm x 85 mm x 166 mm
Enclosure rating IP65
Protection class II 3)
  • 1) May not fall short of or exceed VS tolerances.
  • 2) After loss of reflector < 1 s at max. speed Vmax < 1 m/s.
  • 3) Reference voltage DC 32 V.

Performance

Measuring range 0.15 m … 130 m, on “diamond grade” reflective tape
Target Reflector
Resolution 0.05 mm … 5 mm
Repeatability 2 mm 1) 2)
Accuracy ± 5 mm
Response time 6 ms
Output time 2 ms
Light source Laser, red 3)
visible red light
Laser class 2, complies with 21 CFR 1040.10 and 1040.11 except for the conformance according to “Laser Notice No. 50” from June 24, 2007 (IEC 60825-1:2014, EN 60825-1:2014)
Typ. light spot size (distance) 130 mm (at 70 m)

270 mm (at 150 m)

360 mm (at 220 m)

Max. movement speed 10 m/s
  • 1) On “diamond grade” reflective tape.
  • 2) Statistical error 1 σ, environmental conditions constant, min. warm-up time 10 min.
  • 3) Average service life of 50,000 h at TA = +25 °C.

Interfaces

PROFIBUS DP
Digital output
Number 2
Type Push-pull: PNP/NPN
Maximum output current IA ≤ 100 mA 1) 2)
Multifunctional input (MF) 1 x MF 3) 4)
  • 1) Max. 100 nF/20 mH.
  • 2) HIGH = > VS – 3 V / LOW = < 2 V.
  • 3) HIGH = > 12 V / LOW = < 3 V.
  • 4) Not reverse-polarity protected.

Ambient data

Electromagnetic compatibility (EMC) EN 61000-6-2, EN 55011: Class B
Ambient temperature, operation –10 °C … +55 °C

–10 °C … +75 °C, operation with cooling case

Ambient temperature, storage –25 °C … +75 °C
Effect of air pressure 0.3 ppm/hPa
Effect of air temperature 1 ppm/K
Temperature drift Typ. 0.1 mm/K
Typ. Ambient light immunity ≤ 40,000 lx
Mechanical load Shock: (EN 600 68-2-27 / –2-29)

Sine: (EN 600 68-2-6)

Noise: (EN 600 68-2-64)