CS84-N1112 Color Sensors – SICK Sensor
$ 904.13
SKU: SICK 1028230
SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.
Part Number: 1028230
Color Sensor Model: CS84-N1112
OEM Spec Ref
Features
Dimensions (W x H x D) | 30.4 mm x 80 mm x 53 mm |
Sensing distance | 12.5 mm 1) |
Sensing distance tolerance | ± 3 mm |
Housing design (light emission) | Rectangular |
Light source | LED, RGB 2) |
Wave length | 640 nm, 525 nm, 470 nm |
Light spot size | 2 mm x 4 mm |
Light spot direction | Vertical |
Adjustment | Teach-in button |
Teach-in mode | Static 1-point teach-in |
- 1) From front edge of lens.
- 2) Average service life: 100,000 h at TU = +25 °C.
Mechanics/electronics
Supply voltage | 10 V DC … 30 V DC 1) |
Ripple | < 5 Vpp 2) |
Current consumption | < 120 mA 3) |
Switching frequency | 0.5 kHz 4)
1 kHz 3.5 kHz Adjustable |
Response time | 1,000 µs, 500 µs, 145 µs 5) |
Switching output | NPN |
Switching output (voltage) | NPN: HIGH = approx. VS / LOW ≤ 2 V |
Output (channel) | 4 colors |
Output current Imax. | < 100 mA 6) |
Input, teach-in (ET) | NPN
Teach: U < 2 V Run: U = 10 V … < UV |
Input, blanking input (AT) | NPN
Blanked: U < 2 V Free-running: U > 10 V … < Uv 7) |
Retention time (ET) | 25 ms, non-volatile memory |
Time delay | Deactivation delay 20 ms, shiftable |
Connection type | Male connector M12, 8-pin |
Protection class | II 8) |
Circuit protection | UV connections, reverse polarity protected
Output Q short-circuit protected Interference pulse suppression |
Enclosure rating | IP67 |
Weight | 400 g |
Housing material | Metal, zinc diecast |
- 1) Limit values when operated in short-circuit protected network: max. 8 A.
- 2) May not exceed or fall below Uv tolerances.
- 3) Without load.
- 4) With light/dark ratio 1:1.
- 5) Signal transit time with resistive load.
- 6) Consumption count Q1 / Q2.
- 7) AT > 200 µs.
- 8) Reference voltage DC 32 V.