CS84-N1112 Color Sensors – SICK Sensor

$ 864.82

SKU SICK 1028230 Category

SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.

Part Number: 1028230
Color Sensor Model: CS84-N1112
OEM Spec Ref 

Features

Dimensions (W x H x D) 30.4 mm x 80 mm x 53 mm
Sensing distance 12.5 mm 1)
Sensing distance tolerance ± 3 mm
Housing design (light emission) Rectangular
Light source LED, RGB 2)
Wave length 640 nm, 525 nm, 470 nm
Light spot size 2 mm x 4 mm
Light spot direction Vertical
Adjustment Teach-in button
Teach-in mode Static 1-point teach-in
  • 1) From front edge of lens.
  • 2) Average service life: 100,000 h at TU = +25 °C.

 

Mechanics/electronics

Supply voltage 10 V DC … 30 V DC 1)
Ripple < 5 Vpp 2)
Current consumption < 120 mA 3)
Switching frequency 0.5 kHz 4)

1 kHz

3.5 kHz

Adjustable

Response time 1,000 µs, 500 µs, 145 µs 5)
Switching output NPN
Switching output (voltage) NPN: HIGH = approx. VS / LOW ≤ 2 V
Output (channel) 4 colors
Output current Imax. < 100 mA 6)
Input, teach-in (ET) NPN

Teach: U < 2 V

Run: U = 10 V … < UV

Input, blanking input (AT) NPN

Blanked: U < 2 V

Free-running: U > 10 V … < Uv 7)

Retention time (ET) 25 ms, non-volatile memory
Time delay Deactivation delay 20 ms, shiftable
Connection type Male connector M12, 8-pin
Protection class II 8)
Circuit protection UV connections, reverse polarity protected

Output Q short-circuit protected

Interference pulse suppression

Enclosure rating IP67
Weight 400 g
Housing material Metal, zinc diecast
  • 1) Limit values when operated in short-circuit protected network: max. 8 A.
  • 2) May not exceed or fall below Uv tolerances.
  • 3) Without load.
  • 4) With light/dark ratio 1:1.
  • 5) Signal transit time with resistive load.
  • 6) Consumption count Q1 / Q2.
  • 7) AT > 200 µs.
  • 8) Reference voltage DC 32 V.