CQ4-08ENSKU1 Capacitive Proximity Sensors – SICK Sensor

$ 128.57

SKU: SICK 6051011

SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.

Part Number: 6051011
Capacitive Proximity Sensor Model: CQ4-08ENSKU1
OEM Spec Ref 

Features

Housing Rectangular
Dimensions (W x H x D) 16 mm x 39.5 mm x 12 mm
Sensing range Sn 1 mm … 8 mm 1)

1 mm … 6 mm 2)

Safe sensing range Sa 5.76 mm
Installation type Non-flush

Flush

Switching frequency 100 Hz
Connection type Cable, 3-wire, 2 m 3)
Switching output NPN
Output function NO
Electrical wiring DC 3-wire
Adjustment Potentiometer, 5 turns (Sensitivity)
Enclosure rating IP67 4)
  • 1) For non-flush installation.
  • 2) For flush mounting.
  • 3) Do not bend below 0 °C.
  • 4) According to EN 60529.

 

Mechanics/electronics

Supply voltage 10 V DC … 30 V DC
Ripple ≤ 10 %
Voltage drop ≤ 2.5 V DC 1)
Current consumption 12 mA 2)
Time delay before availability ≤ 200 ms
Hysteresis 4 % … 20 % 3)
Reproducibility ≤ 5 % 4) 5)
Temperature drift (of Sr) ± 20 %
EMC According to EN 60947-5-2
Continuous current Ia ≤ 150 mA
Cable material PVC
Short-circuit protection
Reverse polarity protection
Power-up pulse protection
Shock and vibration resistance 30 g, 11 ms / 10 … 55 Hz, 1 mm
Ambient operating temperature –20 °C … +75 °C
Ambient temperature, storage –40 °C … +85 °C
Housing material Plastic, ABS
Sensing face material Plastic
Items supplied Screwdriver for potentiometer adjustment (1 x)
UL File No. NRKH.E191603
  • 1) At Ia max.
  • 2) Without load.
  • 3) Depending on installation and environmental conditions and sensitivity adjustment, hysteresis may vary.
  • 4) Of Sr.
  • 5) Ub and Ta constant.

 

Safety-related parameters

MTTFD 1,344 years
DCavg 0 %
TM (mission time) 20 years

Reduction factors

Note The values are reference values which may vary
Metal 1
Water 1
PVC Approx. 0.4
Oil Approx. 0.25
Glass 0.6
Ceramics 0.5
Alcohol 0.7
Wood 0.2 … 0.7