$ 454.71 Original price was: $ 454.71.$ 390.54Current price is: $ 390.54.
Manufacturer Part Number: Festo 8086610
Festo Remote I/O and Network Interface Components: CPX-AP-I-EP-M12
The Festo CPX-AP-I-EP-M12, with MPN 8086610 remote I/O and network interface component, is a sophisticated EtherNet/IP interface designed to streamline and enhance communication in complex pneumatic systems. This interface is an essential component for modern industrial automation applications, facilitating seamless integration with Ethernet networks.
Key Features:
Benefits:
Applications:
The Festo CPX-AP-I-EP-M12 remote I/O and network interface component EtherNet/IP interface stands as a testament to Festo’s dedication to innovation and quality in the field of industrial automation, offering a powerful solution for enhancing connectivity and functionality in automated systems.
| Feature | Specification |
|---|---|
| Dimensions W x L x H | 45 mm x 170 mm x 35 mm |
| Type of mounting | On H-rail with accessories With through-hole |
| Max. number of modules | 80 |
| Product weight | 194 g |
| Ambient temperature | -20 °C … 50 °C |
| Storage temperature | -40 °C … 70 °C |
| Relative air humidity | 5 – 95 % Non-condensing |
| Degree of protection | IP65 IP67 |
| Note on degree of protection | Unused connections sealed |
| Corrosion resistance class (CRC) | 1 – Low corrosion stress |
| Max. cable length | 50 m system communication |
| Information on max. cable length | Power supply according to nominal voltage |
| LABS (PWIS) conformity | VDMA24364-B2-L |
| CE marking (see declaration of conformity) | As per EU EMC directive |
| UKCA marking (see declaration of conformity) | To UK instructions for EMC |
| KC characters | KC EMC |
| Certification | RCM compliance mark c UL us – Listed (OL) |
| Certificate issuing authority | UL E239998 |
| Note on materials | RoHS-compliant |
| Housing material | PA PC Die-cast zinc, nickel-plated |
| O-ring material | FPM |
| Diagnostics via LED | Diagnostics per module Network status Ethernet/IP Power supply for electronics/sensors Load power supply System diagnostics Maintenance required |
| Diagnostics via bus | APDD invalid Load switch-off Communication with AP module interrupted Electronics/sensors overvoltage Load overvoltage Electronics/sensors undervoltage Load undervoltage |
| Diagnose per internal communication | Module error Output short circuit/overload Short circuit/overload in sensor supply Load supply undervoltage |
| Fieldbus interface, type | Ethernet |
| Fieldbus interface, protocol | EtherNet/IP |
| Fieldbus interface, function | Bus connection, incoming/forwarding |
| Fieldbus interface, connection type | 2x socket |
| Fieldbus interface, connection technology | M12x1, D-coded as per EN 61076-2-101 |
| Fieldbus interface, number of poles/wires | 4 |
| Fieldbus interface, galvanic isolation | yes |
| Fieldbus interface, transmission rate | 100 Mbit/s |
| Max. address capacity inputs | 1324 byte |
| Max. address capacity outputs | 1324 byte |
| Configuration support | EDS file |
| Communication interface, function | System communication XF20 OUT / XF21 OUT |
| Communication interface, connection type | 2x socket |
| Communication interface, connection technology | M8x1, D-coded as per EN 61076-2-114 |
| Communication interface, number of pins/wires | 4 |
| Communication interface, protocol | AP |
| Communication interface, shielding | yes |
| Power supply, function | Incoming electronics/sensors and load |
| Power supply, type of connection | Plug |
| Power supply, connection technology | M8x1, A-coded as per EN 61076-2-104 |
| Power supply, number of pins/wires | 4 |
| Voltage forwarding, function | Outgoing electronics/sensors and load |
| Voltage forwarding, connection type | Socket |
| Voltage forwarding, connection technology | M8x1, A-coded as per EN 61076-2-104 |
| Voltage forwarding, number of pins/wires | 4 |
| Note regarding operating voltage | SELV/PELV fixed power supplies required, Note voltage drop |
| Nominal operating voltage DC load | 24 V |
| Permissible voltage fluctuations load | ± 25 % |
| Nominal operating voltage DC for electronics/sensors | 24 V |
| Permissible voltage fluctuations for electronics/sensors | ± 25 % |
| Max. power supply | 2 x 4 A (external fuse required) |
| Intrinsic current consumption at nominal operating voltage for electronics/sensors | Typically 90 mA |
| Intrinsic current consumption at nominal operating voltage load | Typically 5 mA |
| Power failure buffering | 10 ms |
| Reverse polarity protection | yes |