Contactor AC 220 V 50/60 HZ AC3 3 kW 400 V AUX contacts: 1 NO 3-pole, size S00 screw terminal – Siemens Contactors

$ 26.22

SKU 3RT6015-1AN21 Category

Product Description

Features

product brand name SIRIUS
product designation Power contactor
product type designation 3RT6
General technical data
size of contactor S00
product extension auxiliary switch Yes
 power loss [W] for rated value of the current
● at AC in hot operating state per pole
● without load current share typical
0.42 W
1.05 W
type of calculation of power loss depending on pole quadratic
insulation voltage rated value 690 V
degree of pollution 3
surge voltage resistance rated value 6 Kv
maximum permissible voltage for protective separation between
coil and main contacts according to EN 60947-1
400 V
shock resistance at rectangular impulse
● at AC
6,7g / 5 ms, 4,2g / 10 ms
 shock resistance with sine pulse
● at AC
10,5g / 5 ms, 6,6g / 10 ms
mechanical service life (operating cycles)
● of contactor typical
● of the contactor with added auxiliary switch block typical
30 000 000
10 000 000
Substance Prohibitance (Date) 5/1/2012
 Weight 0.233 kg
Ambient conditions
installation altitude at height above sea level maximum 2 000 m
 ambient temperature
● during operation
● during storage
-25 … +60 °C
-55 … +80 °C
Main circuit
number of poles for main current circuit 3
number of NO contacts for main contacts 3
number of NC contacts for main contacts 0
 operating voltage
● at AC-3 rated value maximum
● at AC-3e rated value maximum
690 V
690 V
operational current
● at AC-1 up to 690 V
— at ambient temperature 40 °C rated value
— at ambient temperature 60 °C rated value
● at AC-3
— at 400 V rated value
— at 690 V rated value
● at AC-3e
— at 400 V rated value
— at 690 V rated value

18 A
16 A

7 A
4.9 A

7 A
4.9A

 connectable conductor cross-section in main circuit at AC
1
● at 60 °C minimum permissible
● at 40 °C minimum permissible

2.5 mm²
2.5 mm²

 operational current for approx. 200000 operating cycles at
AC-4
● at 400 V rated value
● at 690 V rated value

2.6 A
1.8 A

 operating power
● at AC-1
— at 230 V rated value
— at 230 V at 60 °C rated value
— at 400 V at 60 °C rated value
— at 690 V at 60 °C rated value
● at AC-3
— at 230 V rated value
— at 400 V rated value
— at 690 V rated value
● at AC-3e
— at 230 V rated value
— at 400 V rated value
— at 690 V rated value

6.3 kW
6 kW
10.5 kW
18 kW

1.5 kW
3 kW
4 kW

1.5 kW
3 kW
4 Kw

operating power for approx. 200000 operating cycles at AC
4
● at 400 V rated value
● at 690 V rated value

1.15 kW
1.15 kW

 no-load switching frequency
● at AC
10 000 1/h
 operating frequency
● at AC-1 maximum
● at AC-3 maximum
● at AC-3e maximum
● at AC-4 maximum
1 000 1/h
750 1/h
750 1/h
250 1/h
 Control circuit/ Control
type of voltage of the control supply voltage AC
 control supply voltage at AC
● at 50 Hz rated value 220 V
● at 60 Hz rated value
220 V
220 V
operating range factor control supply voltage rated value of
magnet coil at AC
● at 50 Hz 0.8 … 1.1
● at 60 Hz

0.8 … 1.1
0.85 … 1.1

apparent pick-up power of magnet coil at AC
● at 50 Hz
● at 60 Hz
27 VA
31.7 VA
inductive power factor with closing power of the coil
● at 50 Hz
● at 60 Hz
0.8
0.81
 apparent holding power of magnet coil at AC
● at 50 Hz
● at 60 Hz
4.2 VA
4.8 VA
 inductive power factor with the holding power of the coil
● at 50 Hz
● at 60 Hz
0.25
0.25
Auxiliary circuit
number of NC contacts for auxiliary contacts instantaneous contact 0
number of NO contacts for auxiliary contacts instantaneous
contact
1
operational current at AC-12 maximum 10 A
operational current at AC-15
● at 230 V rated value
● at 400 V rated value
● at 690 V rated value
10 A
3 A
1 A
 operational current at DC-12
● at 24 V rated value
● at 110 V rated value
● at 220 V rated value
6 A
3 A
1 A
 operational current at DC-13
● at 24 V rated value
● at 110 V rated value
● at 220 V rated value
6 A
1 A
0.3 A
contact reliability of auxiliary contacts 1 faulty switching per 100 million (17 V, 1 mA)
UL/CSA ratings
yielded mechanical performance [hp] for 3-phase AC motor at
460/480 V rated value
3 hp
Short-circuit protection
design of the fuse link
● for short-circuit protection of the main circuit
— with type of coordination 1 required
— with type of assignment 2 required
● for short-circuit protection of the auxiliary switch required

gL/gG LV HRC 3NA, DIAZED 5SB, NEOZED 5SE: 35 A
gL/gG LV HRC 3NA, DIAZED 5SB, NEOZED 5SE: 20 A
fuse gL/gG: 10 A

Installation/ mounting/ dimensions
mounting position +/-180° rotation possible on vertical mounting surface; can be tilted forward and
backward by +/- 22.5° on vertical mounting surface
fastening method side-by-side mounting Yes
fastening method screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 50022
height 57.5 mm
width 45 mm
depth 73 mm
required spacing
● with side-by-side mounting
— at the side
0 mm
Connections/ Terminals
type of electrical connection
● for main current circuit
● for auxiliary and control circuit
screw-type terminals
screw-type terminals
 type of connectable conductor cross-sections for main contacts
● solid or stranded
● finely stranded with core end processing
2x (0.5 … 1.5 mm²), 2x (0.75 … 2.5 mm²)
2x (0,5 … 1,5 mm²), 2x (0,75 … 2,5 mm²), 2x 4 mm²
 type of connectable conductor cross-sections
● for auxiliary contacts
— solid or stranded
— finely stranded with core end processing
● for AWG cables for auxiliary contacts

2x (0,5 … 1,5 mm²), 2x (0,75 … 2,5 mm²), 2x 4 mm²
2x (0.5 … 1.5 mm²), 2x (0.75 … 2.5 mm²)
2x (20 … 16), 2x (18 … 14), 2x 12

Safety related data
product function mirror contact according to IEC 60947-4-1 Yes
Electrical Safety
protection class IP on the front according to IEC 60529 IP20 IP20
touch protection on the front according to IEC 60529 finger-safe, for vertical contact from the front