| product brand name | SIRIUS | 
| product designation | Power contactor | 
| product type designation | 3RT6 | 
| General technical data | |
| size of contactor | S00 | 
| product extension auxiliary switch | Yes | 
|  power loss [W] for rated value of the current ● at AC in hot operating state per pole ● without load current share typical  | 
0.42 W 1.05 W  | 
| type of calculation of power loss depending on pole | quadratic | 
| insulation voltage rated value | 690 V | 
| degree of pollution | 3 | 
| surge voltage resistance rated value | 6 Kv | 
| maximum permissible voltage for protective separation between coil and main contacts according to EN 60947-1  | 
400 V | 
| shock resistance at rectangular impulse ● at AC  | 
6,7g / 5 ms, 4,2g / 10 ms | 
|  shock resistance with sine pulse ● at AC  | 
10,5g / 5 ms, 6,6g / 10 ms | 
| mechanical service life (operating cycles) ● of contactor typical ● of the contactor with added auxiliary switch block typical  | 
30 000 000 10 000 000  | 
| Substance Prohibitance (Date) | 5/1/2012 | 
| Weight | 0.233 kg | 
| Ambient conditions | |
| installation altitude at height above sea level maximum | 2 000 m | 
|  ambient temperature ● during operation ● during storage  | 
-25 … +60 °C -55 … +80 °C  | 
| Main circuit | |
| number of poles for main current circuit | 3 | 
| number of NO contacts for main contacts | 3 | 
| number of NC contacts for main contacts | 0 | 
|  operating voltage ● at AC-3 rated value maximum ● at AC-3e rated value maximum  | 
690 V 690 V  | 
| operational current ● at AC-1 up to 690 V — at ambient temperature 40 °C rated value — at ambient temperature 60 °C rated value ● at AC-3 — at 400 V rated value — at 690 V rated value ● at AC-3e — at 400 V rated value — at 690 V rated value  | 
 18 A 7 A 7 A  | 
|  connectable conductor cross-section in main circuit at AC 1 ● at 60 °C minimum permissible ● at 40 °C minimum permissible  | 
 2.5 mm²  | 
|  operational current for approx. 200000 operating cycles at AC-4 ● at 400 V rated value ● at 690 V rated value  | 
 2.6 A  | 
|  operating power ● at AC-1 — at 230 V rated value — at 230 V at 60 °C rated value — at 400 V at 60 °C rated value — at 690 V at 60 °C rated value ● at AC-3 — at 230 V rated value — at 400 V rated value — at 690 V rated value ● at AC-3e — at 230 V rated value — at 400 V rated value — at 690 V rated value  | 
 6.3 kW 1.5 kW 1.5 kW  | 
| operating power for approx. 200000 operating cycles at AC 4 ● at 400 V rated value ● at 690 V rated value  | 
 1.15 kW  | 
|  no-load switching frequency ● at AC  | 
10 000 1/h | 
|  operating frequency ● at AC-1 maximum ● at AC-3 maximum ● at AC-3e maximum ● at AC-4 maximum  | 
1 000 1/h 750 1/h 750 1/h 250 1/h  | 
| Control circuit/ Control | |
| type of voltage of the control supply voltage | AC | 
|  control supply voltage at AC ● at 50 Hz rated value 220 V ● at 60 Hz rated value  | 
220 V 220 V  | 
| operating range factor control supply voltage rated value of magnet coil at AC ● at 50 Hz 0.8 … 1.1 ● at 60 Hz  | 
 0.8 … 1.1  | 
| apparent pick-up power of magnet coil at AC ● at 50 Hz ● at 60 Hz  | 
27 VA 31.7 VA  | 
| inductive power factor with closing power of the coil ● at 50 Hz ● at 60 Hz  | 
0.8 0.81  | 
|  apparent holding power of magnet coil at AC ● at 50 Hz ● at 60 Hz  | 
4.2 VA 4.8 VA  | 
|  inductive power factor with the holding power of the coil ● at 50 Hz ● at 60 Hz  | 
0.25 0.25  | 
| Auxiliary circuit | |
| number of NC contacts for auxiliary contacts instantaneous contact | 0 | 
| number of NO contacts for auxiliary contacts instantaneous contact  | 
1 | 
| operational current at AC-12 maximum | 10 A | 
| operational current at AC-15 ● at 230 V rated value ● at 400 V rated value ● at 690 V rated value  | 
10 A 3 A 1 A  | 
|  operational current at DC-12 ● at 24 V rated value ● at 110 V rated value ● at 220 V rated value  | 
6 A 3 A 1 A  | 
|  operational current at DC-13 ● at 24 V rated value ● at 110 V rated value ● at 220 V rated value  | 
6 A 1 A 0.3 A  | 
| contact reliability of auxiliary contacts | 1 faulty switching per 100 million (17 V, 1 mA) | 
| UL/CSA ratings | |
| yielded mechanical performance [hp] for 3-phase AC motor at 460/480 V rated value  | 
3 hp | 
| Short-circuit protection | |
| design of the fuse link ● for short-circuit protection of the main circuit — with type of coordination 1 required — with type of assignment 2 required ● for short-circuit protection of the auxiliary switch required  | 
 gL/gG LV HRC 3NA, DIAZED 5SB, NEOZED 5SE: 35 A  | 
| Installation/ mounting/ dimensions | |
| mounting position | +/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface  | 
| fastening method side-by-side mounting | Yes | 
| fastening method | screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 50022 | 
| height | 57.5 mm | 
| width | 45 mm | 
| depth | 73 mm | 
| required spacing ● with side-by-side mounting — at the side  | 
0 mm | 
| Connections/ Terminals | |
| type of electrical connection ● for main current circuit ● for auxiliary and control circuit  | 
screw-type terminals screw-type terminals  | 
|  type of connectable conductor cross-sections for main contacts ● solid or stranded ● finely stranded with core end processing  | 
2x (0.5 … 1.5 mm²), 2x (0.75 … 2.5 mm²) 2x (0,5 … 1,5 mm²), 2x (0,75 … 2,5 mm²), 2x 4 mm²  | 
|  type of connectable conductor cross-sections ● for auxiliary contacts — solid or stranded — finely stranded with core end processing ● for AWG cables for auxiliary contacts  | 
 2x (0,5 … 1,5 mm²), 2x (0,75 … 2,5 mm²), 2x 4 mm²  | 
| Safety related data | |
| product function mirror contact according to IEC 60947-4-1 | Yes | 
| Electrical Safety | |
| protection class IP on the front according to IEC 60529 IP20 | IP20 | 
| touch protection on the front according to IEC 60529 | finger-safe, for vertical contact from the front |