C4MT-01214ABB03BE0 – Safety Light Curtains – SICK Sensor Accessories

$ 852.28

SKU: SICK 1048811

Part Number: 1048811
Non-contact safety switches: C4MT-01214ABB03BE0
OEM Spec Ref

Features

System part 2 Twin-Sticks
Usage miniTwin4 as a standalone device

miniTwin4 as last guest for 2- or 3-device cascade

Mounting system type C-fix or L-fix bracket
Resolution 14 mm
Scanning range
Minimum 0 m … 4 m
Typical 0 m … 5 m
Protective field height 120 mm
Response time ≤ 14 ms 1)
Synchronization Optical, without separate synchronization
Items supplied Twin stick

System plug

C-Fix bracket and L-Fix bracket, 2 pieces each

Test rod with diameter corresponding to the resolution of the safety light curtain

Safety instruction

Mounting instructions

Operating instructions for download

  • 1) Standalone devices, no cascaded systems. Other response times can be found in the operating instructions.

Safety-related parameters

Type Type 4 (IEC 61496-1)
Safety integrity level SIL3 (IEC 61508)

SILCL3 (EN 62061)

Category Category 4 (EN ISO 13849)
Performance level PL e (EN ISO 13849)
PFHD (mean probability of a dangerous failure per hour) Standalone system: 4.3 x 10-9 (EN ISO 13849)
TM (mission time) 20 years (EN ISO 13849)
Safe state in the event of a fault At least one OSSD is in the OFF state.

Functions

Functions Delivery status
Restart interlock Deactivated
External device monitoring (EDM) Deactivated
Beam coding Automatic

Interfaces

System connection Male connector M12, 5-pin
Length of cable 160 mm
Conductor cross-section 0.34 mm²
Permitted cable length ≤ 20 m 1)
Configuration method Hard wired
Display elements LEDs
Fieldbus, industrial network
Integration via Flexi Soft safety controller CANopen 2)
DeviceNet™
EtherCAT®
EtherNet/IP™
Modbus TCP
PROFIBUS DP
PROFINET
  • 1) Depending on load, power supply and wire cross-section. The technical specifications must be observed.
  • 2) For additional information on Flexi Soft -> www.sick.com/Flexi_Soft.

Electrical data

Protection class III (EN 61140)
Supply voltage VS 24 V DC (19.2 V DC … 28.8 V DC)
Ripple ≤ 10 % 1)
Power consumption ≤ 3 A 2)
Output signal switching devices (OSSDs)
Type of output PNP semiconductors, short-circuit protected, cross-circuit monitored 3)
ON state, switching voltage HIGH 24 V DC (VS – 2.25 V DC … VS)
OFF state, switching voltage LOW ≤ 2 V DC
Current-carrying capacity per OSSD ≤ 300 mA
  • 1) Within the limits of VS.
  • 2) Maximum power consumption of a host/guest/guest system with 1,200 mm protective field height and a resolution of 14 mm.
  • 3) Applies to the voltage range between –30 V and +30 V.

Mechanical data

Housing cross-section (incl. system connection) 15 mm x 32 mm
Housing material Aluminum alloy ALMGSI 0.5
Weight 50 g

Ambient data

Enclosure rating IP65 (EN 60529)
Ambient operating temperature –20 °C … +55 °C
Storage temperature –25 °C … +70 °C
Air humidity 15 % … 95 %, Non-condensing
Vibration resistance 5 g, 10 Hz … 55 Hz (EN 60068-2-6)
Shock resistance 10 g, 16 ms (EN 60068-2-27)

Related products