Altivar 12 – Variable Speed Drives With Heatsink – Schneider Variable Speed Drives and Soft Starters
$ 145.86 – $ 210.98
SKU: N/A
Specifications
Main | ||||
Part Number | ATV12H037M2 | ATV12H075M2 | ATV12HU15M2 | ATV12HU22M2 |
Range of product | Altivar 12 | Altivar 12 | Altivar 12 | Altivar 12 |
Product or component type | Variable speed drive | Variable speed drive | Variable speed drive | Variable speed drive |
Product specific application | Simple machine | Simple machine | Simple machine | Simple machine |
Mounting mode | Cabinet mount | Cabinet mount | Cabinet mount | Cabinet mount |
Communication port protocol | Modbus | Modbus | Modbus | Modbus |
supply frequency | 50/60 Hz +/- 5 % | 50/60 Hz +/- 5 % | 50/60 Hz +/- 5 % | 50/60 Hz +/- 5 % |
[Us] rated supply voltage | 200…240 V – 15…10 % | 200…240 V – 15…10 % | 200…240 V – 15…10 % | 200…240 V – 15…10 % |
Nominal output current | 2.4 A | 4.2 A | 7.5 A | 0.416666667 |
motor power hp | 0.55 hp | 1 hp | 2 hp | 3 hp |
motor power kW | 0.37 kW | 0.75 kW | 1.5 kW | 2.2 kW |
motor power hp | 0.55 hp | 1 hp | 2 hp | 3 hp |
EMC filter | Integrated | Integrated | Integrated | Integrated |
IP degree of protection | IP20 | IP20 | IP20 | IP20 |
Complementary | ||||
Discrete input number | 4 | 4 | 4 | 4 |
Discrete output number | 2 | 2 | 2 | 2 |
Analogue input number | 1 | 1 | 1 | 1 |
Analogue output number | 1 | 1 | 1 | 1 |
Relay output number | 1 | 1 | 1 | 1 |
Physical interface | 2-wire RS 485 | 2-wire RS 485 | 2-wire RS 485 | 2-wire RS 485 |
connector type | 1 RJ45 | 1 RJ45 | 1 RJ45 | 1 RJ45 |
continuous output current | 2.4 A at 4 kHz | 4.2 A at 4 kHz | 7.5 A at 4 kHz | 10 A at 4 kHz |
method of access | Server Modbus serial | Server Modbus serial | Server Modbus serial | Server Modbus serial |
Speed drive output frequency | 0.5…400 Hz | 0.5…400 Hz | 0.5…400 Hz | 0.5…400 Hz |
speed range | 1…20 | 1…20 | 1…20 | 1…20 |
sampling duration | 20 ms, tolerance +/- 1 ms for logic input 10 ms for analogue input |
20 ms, tolerance +/- 1 ms for logic input 10 ms for analogue input |
20 ms, tolerance +/- 1 ms for logic input 10 ms for analogue input |
20 ms, tolerance +/- 1 ms for logic input 10 ms for analogue input |
linearity error | +/- 0.3 % of maximum value for analogue input | +/- 0.3 % of maximum value for analogue input | +/- 0.3 % of maximum value for analogue input | +/- 0.3 % of maximum value for analogue input |
frequency resolution | Analog input: converter A/D, 10 bits Display unit: 0.1 Hz |
Analog input: converter A/D, 10 bits Display unit: 0.1 Hz |
Analog input: converter A/D, 10 bits Display unit: 0.1 Hz |
Analog input: converter A/D, 10 bits Display unit: 0.1 Hz |
time constant | 20 ms +/- 1 ms for reference change | 20 ms +/- 1 ms for reference change | 20 ms +/- 1 ms for reference change | 20 ms +/- 1 ms for reference change |
Transmission rate | 9.6 kbit/s 19.2 kbit/s 38.4 kbit/s |
9.6 kbit/s 19.2 kbit/s 38.4 kbit/s |
9.6 kbit/s 19.2 kbit/s 38.4 kbit/s |
9.6 kbit/s 19.2 kbit/s 38.4 kbit/s |
Transmission frame | RTU | RTU | RTU | RTU |
Number of addresses | 1…247 | 1…247 | 1…247 | 1…247 |
Data format | 8 bits, configurable odd, even or no parity | 8 bits, configurable odd, even or no parity | 8 bits, configurable odd, even or no parity | 8 bits, configurable odd, even or no parity |
communication service | Read holding registers (03) 29 words Write single register (06) 29 words Write multiple registers (16) 27 words Read/write multiple registers (23) 4/4 words Read device identification (43) |
Read holding registers (03) 29 words Write single register (06) 29 words Write multiple registers (16) 27 words Read/write multiple registers (23) 4/4 words Read device identification (43) |
Read holding registers (03) 29 words Write single register (06) 29 words Write multiple registers (16) 27 words Read/write multiple registers (23) 4/4 words Read device identification (43) |
Read holding registers (03) 29 words Write single register (06) 29 words Write multiple registers (16) 27 words Read/write multiple registers (23) 4/4 words Read device identification (43) |
Type of polarization | No impedance | No impedance | No impedance | No impedance |
4 quadrant operation possible | FALSE | FALSE | FALSE | FALSE |
Asynchronous motor control profile | Sensorless flux vector control Voltage/frequency ratio (V/f) Quadratic voltage/frequency ratio |
Quadratic voltage/frequency ratio Voltage/frequency ratio (V/f) Sensorless flux vector control |
Sensorless flux vector control Quadratic voltage/frequency ratio Voltage/frequency ratio (V/f) |
Sensorless flux vector control Quadratic voltage/frequency ratio Voltage/frequency ratio (V/f) |
Maximum output frequency | 4 kHz | 4 kHz | 4 kHz | 4 kHz |
transient overtorque | 150…170 % of nominal motor torque depending on drive rating and type of motor | 150…170 % of nominal motor torque depending on drive rating and type of motor | 150…170 % of nominal motor torque depending on drive rating and type of motor | 150…170 % of nominal motor torque depending on drive rating and type of motor |
Acceleration and deceleration ramps | Linear from 0 to 999.9 s S U |
Linear from 0 to 999.9 s U S |
U S Linear from 0 to 999.9 s |
Linear from 0 to 999.9 s U S |
Motor slip compensation | Adjustable Preset in factory |
Preset in factory Adjustable |
Adjustable Preset in factory |
Adjustable Preset in factory |
switching frequency | 2…16 kHz adjustable 4…16 kHz with derating factor |
2…16 kHz adjustable 4…16 kHz with derating factor |
2…16 kHz adjustable 4…16 kHz with derating factor |
2…16 kHz adjustable 4…16 kHz with derating factor |
Nominal switching frequency | 4 kHz | 4 kHz | 4 kHz | 4 kHz |
Braking to standstill | By DC injection | By DC injection | By DC injection | By DC injection |
Brake chopper integrated | FALSE | FALSE | FALSE | FALSE |
line current | 5.9 A at 100 V (heavy duty) 4.9 A at 120 V (heavy duty) |
10.2 A at 100 V (heavy duty) 8.5 A at 120 V (heavy duty) |
17.8 A at 100 V (heavy duty) 14.9 A at 120 V (heavy duty) |
24.0 A at 100 V (heavy duty) 20.2 A at 120 V (heavy duty) |
Maximum input current | 4.9 A | 8.5 A | 14.9 A | 20.2 A |
Maximum output voltage | 240 V | 240 V | 240 V | 240 V |
apparent power | 1.2 kVA at 240 V (heavy duty) | 2.0 kVA at 240 V (heavy duty) | 3.6 kVA at 240 V (heavy duty) | 4.8 kVA at 240 V (heavy duty) |
maximum transient current | 3.6 A during 60 s (heavy duty) 4.0 A during 2 s (heavy duty) |
6.3 A during 60 s (heavy duty) 6.9 A during 2 s (heavy duty) |
11.2 A during 60 s (heavy duty) 12.4 A during 2 s (heavy duty) |
15.0 A during 60 s (heavy duty) 16.5 A during 2 s (heavy duty) |
Network frequency | 50…60 Hz | 50…60 Hz | 50…60 Hz | 50…60 Hz |
Relative symmetric network frequency tolerance | 5% | 0.05 | 0.05 | 0.05 |
Prospective line Isc | 1 kA | 1 kA | 1 kA | 1 kA |
Base load current at high overload | 2.4 A | 4.2 A | 7.5 A | 10.0 A |
power dissipation in W | Natural: 27.0 W | Natural: 44.0 W | Forced cooling: 72.0 W | Forced cooling: 93.0 W |
With safety function Safely Limited Speed (SLS) | FALSE | FALSE | FALSE | FALSE |
With safety function Safe brake management (SBC/SBT) | FALSE | FALSE | FALSE | FALSE |
With safety function Safe Operating Stop (SOS) | FALSE | FALSE | FALSE | FALSE |
With safety function Safe Position (SP) | FALSE | FALSE | FALSE | FALSE |
With safety function Safe programmable logic | FALSE | FALSE | FALSE | FALSE |
With safety function Safe Speed Monitor (SSM) | FALSE | FALSE | FALSE | FALSE |
With safety function Safe Stop 1 (SS1) | FALSE | FALSE | FALSE | FALSE |
With sft fct Safe Stop 2 (SS2) | FALSE | FALSE | FALSE | FALSE |
With safety function Safe torque off (STO) | FALSE | FALSE | FALSE | FALSE |
With safety function Safely Limited Position (SLP) | FALSE | FALSE | FALSE | FALSE |
With safety function Safe Direction (SDI) | FALSE | FALSE | FALSE | FALSE |
protection type | Line supply overvoltage Line supply undervoltage Overcurrent between output phases and earth Overheating protection Short-circuit between motor phases Against input phase loss in three-phase Thermal motor protection via the drive by continuous calculation of I²t |
Line supply overvoltage Line supply undervoltage Overcurrent between output phases and earth Overheating protection Short-circuit between motor phases Against input phase loss in three-phase Thermal motor protection via the drive by continuous calculation of I²t |
Line supply overvoltage Line supply undervoltage Overcurrent between output phases and earth Overheating protection Short-circuit between motor phases Against input phase loss in three-phase Thermal motor protection via the drive by continuous calculation of I²t |
Line supply overvoltage Line supply undervoltage Overcurrent between output phases and earth Overheating protection Short-circuit between motor phases Against input phase loss in three-phase Thermal motor protection via the drive by continuous calculation of I²t |
Tightening torque | 0.8 N.m | 0.8 N.m | 1.2 N.m | 1.2 N.m |
Insulation | Electrical between power and control | Electrical between power and control | Electrical between power and control | Electrical between power and control |
Quantity per set | Set of 1 | Set of 1 | Set of 1 | Set of 1 |
Width | 72 mm | 72 mm | 105 mm | 105 mm |
Height | 143 mm | 143 mm | 142 mm | 142 mm |
Depth | 121.2 mm | 131.2 mm | 156.2 mm | 156.2 mm |
Net weight | 0.7 kg | 0.8 kg | 1.4 kg | 1.4 kg |
Environment | ||||
operating altitude | > 1000…2000 m with current derating 1 % per 100 m <= 1000 m without derating |
> 1000…2000 m with current derating 1 % per 100 m <= 1000 m without derating |
> 1000…2000 m with current derating 1 % per 100 m <= 1000 m without derating |
> 1000…2000 m with current derating 1 % per 100 m <= 1000 m without derating |
Operating position | Vertical +/- 10 degree | Vertical +/- 10 degree | Vertical +/- 10 degree | Vertical +/- 10 degree |
Product certifications | NOM CSA C-Tick UL GOST RCM KC |
NOM CSA C-Tick UL GOST RCM KC |
NOM CSA C-Tick UL GOST RCM KC |
NOM CSA C-Tick UL GOST RCM KC |
Marking | CE | CE | CE | CE |
Standards | UL 508C UL 618000-5-1 EN/IEC 61800-5-1 EN/IEC 61800-3 |
UL 508C UL 618000-5-1 EN/IEC 61800-5-1 EN/IEC 61800-3 |
UL 508C UL 618000-5-1 EN/IEC 61800-5-1 EN/IEC 61800-3 |
UL 508C UL 618000-5-1 EN/IEC 61800-5-1 EN/IEC 61800-3 |
Assembly style | With heat sink | With heat sink | With heat sink | With heat sink |
electromagnetic compatibility | Electrical fast transient/burst immunity test level 4 conforming to EN/IEC 61000-4-4 Electrostatic discharge immunity test level 3 conforming to EN/IEC 61000-4-2 Immunity to conducted disturbances level 3 conforming to EN/IEC 61000-4-6 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to EN/IEC 61000-4-3 Surge immunity test level 3 conforming to EN/IEC 61000-4-5 Voltage dips and interruptions immunity test conforming to EN/IEC 61000-4-11 |
Electrical fast transient/burst immunity test level 4 conforming to EN/IEC 61000-4-4 Electrostatic discharge immunity test level 3 conforming to EN/IEC 61000-4-2 Immunity to conducted disturbances level 3 conforming to EN/IEC 61000-4-6 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to EN/IEC 61000-4-3 Surge immunity test level 3 conforming to EN/IEC 61000-4-5 Voltage dips and interruptions immunity test conforming to EN/IEC 61000-4-11 |
Electrical fast transient/burst immunity test level 4 conforming to EN/IEC 61000-4-4 Electrostatic discharge immunity test level 3 conforming to EN/IEC 61000-4-2 Immunity to conducted disturbances level 3 conforming to EN/IEC 61000-4-6 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to EN/IEC 61000-4-3 Surge immunity test level 3 conforming to EN/IEC 61000-4-5 Voltage dips and interruptions immunity test conforming to EN/IEC 61000-4-11 |
Electrical fast transient/burst immunity test level 4 conforming to EN/IEC 61000-4-4 Electrostatic discharge immunity test level 3 conforming to EN/IEC 61000-4-2 Immunity to conducted disturbances level 3 conforming to EN/IEC 61000-4-6 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to EN/IEC 61000-4-3 Surge immunity test level 3 conforming to EN/IEC 61000-4-5 Voltage dips and interruptions immunity test conforming to EN/IEC 61000-4-11 |
Environmental class (during operation) | Class 3C3 according to IEC 60721-3-3 Class 3S2 according to IEC 60721-3-3 |
Class 3C3 according to IEC 60721-3-3 Class 3S2 according to IEC 60721-3-3 |
Class 3C3 according to IEC 60721-3-3 Class 3S2 according to IEC 60721-3-3 |
Class 3C3 according to IEC 60721-3-3 Class 3S2 according to IEC 60721-3-3 |
Maximum acceleration under shock impact (during operation) | 150 m/s² at 11 ms | 150 m/s² at 11 ms | 150 m/s² at 11 ms | 150 m/s² at 11 ms |
Maximum acceleration under vibrational stress (during operation) | 10 m/s² at 13…200 Hz | 10 m/s² at 13…200 Hz | 10 m/s² at 13…200 Hz | 10 m/s² at 13…200 Hz |
Maximum deflection under vibratory load (during operation) | 1.5 mm at 2…13 Hz | 1.5 mm at 2…13 Hz | 1.5 mm at 2…13 Hz | 1.5 mm at 2…13 Hz |
Overvoltage category | Class III | Class III | Class III | Class III |
Regulation loop | Adjustable PID regulator | Adjustable PID regulator | Adjustable PID regulator | Adjustable PID regulator |
electromagnetic emission | Radiated emissions environment 1 category C2 conforming to EN/IEC 61800-3 2…16 kHz shielded motor cable Conducted emissions with integrated EMC filter environment 1 category C1 conforming to EN/IEC 61800-3 2, 4, 8, 12 and 16 kHz shielded motor cable <5 m Conducted emissions with integrated EMC filter environment 1 category C2 conforming to EN/IEC 61800-3 2…12 kHz shielded motor cable <5 m Conducted emissions with integrated EMC filter environment 1 category C2 conforming to EN/IEC 61800-3 2, 4 and 16 kHz shielded motor cable <10 m Conducted emissions with additional EMC filter environment 1 category C1 conforming to EN/IEC 61800-3 4…12 kHz shielded motor cable <20 m Conducted emissions with additional EMC filter environment 1 category C2 conforming to EN/IEC 61800-3 4…12 kHz shielded motor cable <50 m Conducted emissions with additional EMC filter environment 2 category C3 conforming to EN/IEC 61800-3 4…12 kHz shielded motor cable <50 m |
Radiated emissions environment 1 category C2 conforming to EN/IEC 61800-3 2…16 kHz shielded motor cable Conducted emissions with integrated EMC filter environment 1 category C1 conforming to EN/IEC 61800-3 2, 4, 8, 12 and 16 kHz shielded motor cable <5 m Conducted emissions with integrated EMC filter environment 1 category C2 conforming to EN/IEC 61800-3 2…12 kHz shielded motor cable <5 m Conducted emissions with integrated EMC filter environment 1 category C2 conforming to EN/IEC 61800-3 2, 4 and 16 kHz shielded motor cable <10 m Conducted emissions with additional EMC filter environment 1 category C1 conforming to EN/IEC 61800-3 4…12 kHz shielded motor cable <20 m Conducted emissions with additional EMC filter environment 1 category C2 conforming to EN/IEC 61800-3 4…12 kHz shielded motor cable <50 m Conducted emissions with additional EMC filter environment 2 category C3 conforming to EN/IEC 61800-3 4…12 kHz shielded motor cable <50 m |
Radiated emissions environment 1 category C2 conforming to EN/IEC 61800-3 2…16 kHz shielded motor cable Conducted emissions with integrated EMC filter environment 1 category C1 conforming to EN/IEC 61800-3 2, 4, 8, 12 and 16 kHz shielded motor cable <5 m Conducted emissions with additional EMC filter environment 1 category C1 conforming to EN/IEC 61800-3 4…12 kHz shielded motor cable <20 m Conducted emissions with additional EMC filter environment 1 category C2 conforming to EN/IEC 61800-3 4…12 kHz shielded motor cable <50 m Conducted emissions with additional EMC filter environment 2 category C3 conforming to EN/IEC 61800-3 4…12 kHz shielded motor cable <50 m Conducted emissions with integrated EMC filter environment 1 category C2 conforming to EN/IEC 61800-3 4…16 kHz shielded motor cable <5 m Conducted emissions with integrated EMC filter environment 1 category C2 conforming to EN/IEC 61800-3 2, 4, 8, 12 and 16 kHz shielded motor cable <10 m |
Radiated emissions environment 1 category C2 conforming to EN/IEC 61800-3 2…16 kHz shielded motor cable Conducted emissions with integrated EMC filter environment 1 category C1 conforming to EN/IEC 61800-3 2, 4, 8, 12 and 16 kHz shielded motor cable <5 m Conducted emissions with additional EMC filter environment 1 category C1 conforming to EN/IEC 61800-3 4…12 kHz shielded motor cable <20 m Conducted emissions with additional EMC filter environment 1 category C2 conforming to EN/IEC 61800-3 4…12 kHz shielded motor cable <50 m Conducted emissions with additional EMC filter environment 2 category C3 conforming to EN/IEC 61800-3 4…12 kHz shielded motor cable <50 m Conducted emissions with integrated EMC filter environment 1 category C2 conforming to EN/IEC 61800-3 4…16 kHz shielded motor cable <5 m Conducted emissions with integrated EMC filter environment 1 category C2 conforming to EN/IEC 61800-3 2, 4, 8, 12 and 16 kHz shielded motor cable <10 m |
vibration resistance | 1 gn (f = 13…200 Hz) conforming to EN/IEC 60068-2-6 1.5 mm peak to peak (f = 3…13 Hz) – drive unmounted on symmetrical DIN rail – conforming to EN/IEC 60068-2-6 |
1 gn (f = 13…200 Hz) conforming to EN/IEC 60068-2-6 1.5 mm peak to peak (f = 3…13 Hz) – drive unmounted on symmetrical DIN rail – conforming to EN/IEC 60068-2-6 |
1 gn (f = 13…200 Hz) conforming to EN/IEC 60068-2-6 1.5 mm peak to peak (f = 3…13 Hz) – drive unmounted on symmetrical DIN rail – conforming to EN/IEC 60068-2-6 |
1 gn (f = 13…200 Hz) conforming to EN/IEC 60068-2-6 1.5 mm peak to peak (f = 3…13 Hz) – drive unmounted on symmetrical DIN rail – conforming to EN/IEC 60068-2-6 |
shock resistance | 15 gn conforming to EN/IEC 60068-2-27 for 11 ms | 15 gn conforming to EN/IEC 60068-2-27 for 11 ms | 15 gn conforming to EN/IEC 60068-2-27 for 11 ms | 15 gn conforming to EN/IEC 60068-2-27 for 11 ms |
relative humidity | 5…95 % without condensation conforming to IEC 60068-2-3 5…95 % without dripping water conforming to IEC 60068-2-3 |
5…95 % without condensation conforming to IEC 60068-2-3 5…95 % without dripping water conforming to IEC 60068-2-3 |
5…95 % without condensation conforming to IEC 60068-2-3 5…95 % without dripping water conforming to IEC 60068-2-3 |
5…95 % without condensation conforming to IEC 60068-2-3 5…95 % without dripping water conforming to IEC 60068-2-3 |
Noise level | 0 dB | 0 dB | 45 dB | 45 dB |
Pollution degree | 2 | 2 | 2 | 2 |
Ambient air transport temperature | -25…70 °C | -25…70 °C | -25…70 °C | -25…70 °C |
ambient air temperature for operation | -10…40 °C without derating 40…60 °C with current derating 2.2 % per °C |
-10…40 °C without derating 40…60 °C with current derating 2.2 % per °C |
-10…50 °C without derating 50…60 °C with current derating 2.2 % per °C |
-10…50 °C without derating 50…60 °C with current derating 2.2 % per °C |
Ambient air temperature for storage | -25…70 °C | -25…70 °C | -25…70 °C | -25…70 °C |
Packing Units | ||||
Unit Type of Package 1 | PCE | PCE | PCE | PCE |
Number of Units in Package 1 | 1 | 1 | 1 | 1 |
Package 1 Height | 12.600 cm | 11.700 cm | 23 cm | 20.000 cm |
Package 1 Width | 20.000 cm | 19.000 cm | 20 cm | 18.000 cm |
Package 1 Length | 18.700 cm | 19.500 cm | 21.5 cm | 20.000 cm |
Package 1 Weight | 1.035 kg | 1.118 kg | 1.716 kg | 1.753 kg |
Unit Type of Package 2 | P06 | P06 | P06 | P06 |
Number of Units in Package 2 | 45 | 45 | 30 | 30 |
Package 2 Height | 75.000 cm | 75.000 cm | 75 cm | 75.000 cm |
Package 2 Width | 60.000 cm | 60.000 cm | 60 cm | 60.000 cm |
Package 2 Length | 80.000 cm | 80.000 cm | 80 cm | 80.000 cm |
Package 2 Weight | 59.530 kg | 63.085 kg | 64.84 kg | 65.950 kg |
Contractual warranty | ||||
Warranty | 18 months | 18 months | 18 months | 18 months |
Weight | N/A |
---|---|
Dimensions | N/A |