Altivar 12 – Variable Speed Drives With Heatsink – Schneider Variable Speed Drives and Soft Starters

USD $ 139.23USD $ 201.39

SKU: N/A

Specifications

Main
Part Number ATV12H037M2 ATV12H075M2 ATV12HU15M2 ATV12HU22M2
Range of product Altivar 12 Altivar 12 Altivar 12 Altivar 12
Product or component type Variable speed drive Variable speed drive Variable speed drive Variable speed drive
Product specific application Simple machine Simple machine Simple machine Simple machine
Mounting mode Cabinet mount Cabinet mount Cabinet mount Cabinet mount
Communication port protocol Modbus Modbus Modbus Modbus
supply frequency 50/60 Hz +/- 5 % 50/60 Hz +/- 5 % 50/60 Hz +/- 5 % 50/60 Hz +/- 5 %
[Us] rated supply voltage 200…240 V – 15…10 % 200…240 V – 15…10 % 200…240 V – 15…10 % 200…240 V – 15…10 %
Nominal output current 2.4 A 4.2 A 7.5 A 0.416666667
motor power hp 0.55 hp 1 hp 2 hp 3 hp
motor power kW 0.37 kW 0.75 kW 1.5 kW 2.2 kW
motor power hp 0.55 hp 1 hp 2 hp 3 hp
EMC filter Integrated Integrated Integrated Integrated
IP degree of protection IP20 IP20 IP20 IP20
Complementary
Discrete input number 4 4 4 4
Discrete output number 2 2 2 2
Analogue input number 1 1 1 1
Analogue output number 1 1 1 1
Relay output number 1 1 1 1
Physical interface 2-wire RS 485 2-wire RS 485 2-wire RS 485 2-wire RS 485
connector type 1 RJ45 1 RJ45 1 RJ45 1 RJ45
continuous output current 2.4 A at 4 kHz 4.2 A at 4 kHz 7.5 A at 4 kHz 10 A at 4 kHz
method of access Server Modbus serial Server Modbus serial Server Modbus serial Server Modbus serial
Speed drive output frequency 0.5…400 Hz 0.5…400 Hz 0.5…400 Hz 0.5…400 Hz
speed range 1…20 1…20 1…20 1…20
sampling duration 20 ms, tolerance +/- 1 ms for logic input
10 ms for analogue input
20 ms, tolerance +/- 1 ms for logic input
10 ms for analogue input
20 ms, tolerance +/- 1 ms for logic input
10 ms for analogue input
20 ms, tolerance +/- 1 ms for logic input
10 ms for analogue input
linearity error +/- 0.3 % of maximum value for analogue input +/- 0.3 % of maximum value for analogue input +/- 0.3 % of maximum value for analogue input +/- 0.3 % of maximum value for analogue input
frequency resolution Analog input: converter A/D, 10 bits
Display unit: 0.1 Hz
Analog input: converter A/D, 10 bits
Display unit: 0.1 Hz
Analog input: converter A/D, 10 bits
Display unit: 0.1 Hz
Analog input: converter A/D, 10 bits
Display unit: 0.1 Hz
time constant 20 ms +/- 1 ms for reference change 20 ms +/- 1 ms for reference change 20 ms +/- 1 ms for reference change 20 ms +/- 1 ms for reference change
Transmission rate 9.6 kbit/s
19.2 kbit/s
38.4 kbit/s
9.6 kbit/s
19.2 kbit/s
38.4 kbit/s
9.6 kbit/s
19.2 kbit/s
38.4 kbit/s
9.6 kbit/s
19.2 kbit/s
38.4 kbit/s
Transmission frame RTU RTU RTU RTU
Number of addresses 1…247 1…247 1…247 1…247
Data format 8 bits, configurable odd, even or no parity 8 bits, configurable odd, even or no parity 8 bits, configurable odd, even or no parity 8 bits, configurable odd, even or no parity
communication service Read holding registers (03) 29 words
Write single register (06) 29 words
Write multiple registers (16) 27 words
Read/write multiple registers (23) 4/4 words
Read device identification (43)
Read holding registers (03) 29 words
Write single register (06) 29 words
Write multiple registers (16) 27 words
Read/write multiple registers (23) 4/4 words
Read device identification (43)
Read holding registers (03) 29 words
Write single register (06) 29 words
Write multiple registers (16) 27 words
Read/write multiple registers (23) 4/4 words
Read device identification (43)
Read holding registers (03) 29 words
Write single register (06) 29 words
Write multiple registers (16) 27 words
Read/write multiple registers (23) 4/4 words
Read device identification (43)
Type of polarization No impedance No impedance No impedance No impedance
4 quadrant operation possible FALSE FALSE FALSE FALSE
Asynchronous motor control profile Sensorless flux vector control
Voltage/frequency ratio (V/f)
Quadratic voltage/frequency ratio
Quadratic voltage/frequency ratio
Voltage/frequency ratio (V/f)
Sensorless flux vector control
Sensorless flux vector control
Quadratic voltage/frequency ratio
Voltage/frequency ratio (V/f)
Sensorless flux vector control
Quadratic voltage/frequency ratio
Voltage/frequency ratio (V/f)
Maximum output frequency 4 kHz 4 kHz 4 kHz 4 kHz
transient overtorque 150…170 % of nominal motor torque depending on drive rating and type of motor 150…170 % of nominal motor torque depending on drive rating and type of motor 150…170 % of nominal motor torque depending on drive rating and type of motor 150…170 % of nominal motor torque depending on drive rating and type of motor
Acceleration and deceleration ramps Linear from 0 to 999.9 s
S
U
Linear from 0 to 999.9 s
U
S
U
S
Linear from 0 to 999.9 s
Linear from 0 to 999.9 s
U
S
Motor slip compensation Adjustable
Preset in factory
Preset in factory
Adjustable
Adjustable
Preset in factory
Adjustable
Preset in factory
switching frequency 2…16 kHz adjustable
4…16 kHz with derating factor
2…16 kHz adjustable
4…16 kHz with derating factor
2…16 kHz adjustable
4…16 kHz with derating factor
2…16 kHz adjustable
4…16 kHz with derating factor
Nominal switching frequency 4 kHz 4 kHz 4 kHz 4 kHz
Braking to standstill By DC injection By DC injection By DC injection By DC injection
Brake chopper integrated FALSE FALSE FALSE FALSE
line current 5.9 A at 100 V (heavy duty)
4.9 A at 120 V (heavy duty)
10.2 A at 100 V (heavy duty)
8.5 A at 120 V (heavy duty)
17.8 A at 100 V (heavy duty)
14.9 A at 120 V (heavy duty)
24.0 A at 100 V (heavy duty)
20.2 A at 120 V (heavy duty)
Maximum input current 4.9 A 8.5 A 14.9 A 20.2 A
Maximum output voltage 240 V 240 V 240 V 240 V
apparent power 1.2 kVA at 240 V (heavy duty) 2.0 kVA at 240 V (heavy duty) 3.6 kVA at 240 V (heavy duty) 4.8 kVA at 240 V (heavy duty)
maximum transient current 3.6 A during 60 s (heavy duty)
4.0 A during 2 s (heavy duty)
6.3 A during 60 s (heavy duty)
6.9 A during 2 s (heavy duty)
11.2 A during 60 s (heavy duty)
12.4 A during 2 s (heavy duty)
15.0 A during 60 s (heavy duty)
16.5 A during 2 s (heavy duty)
Network frequency 50…60 Hz 50…60 Hz 50…60 Hz 50…60 Hz
Relative symmetric network frequency tolerance 5% 0.05 0.05 0.05
Prospective line Isc 1 kA 1 kA 1 kA 1 kA
Base load current at high overload 2.4 A 4.2 A 7.5 A 10.0 A
power dissipation in W Natural: 27.0 W Natural: 44.0 W Forced cooling: 72.0 W Forced cooling: 93.0 W
With safety function Safely Limited Speed (SLS) FALSE FALSE FALSE FALSE
With safety function Safe brake management (SBC/SBT) FALSE FALSE FALSE FALSE
With safety function Safe Operating Stop (SOS) FALSE FALSE FALSE FALSE
With safety function Safe Position (SP) FALSE FALSE FALSE FALSE
With safety function Safe programmable logic FALSE FALSE FALSE FALSE
With safety function Safe Speed Monitor (SSM) FALSE FALSE FALSE FALSE
With safety function Safe Stop 1 (SS1) FALSE FALSE FALSE FALSE
With sft fct Safe Stop 2 (SS2) FALSE FALSE FALSE FALSE
With safety function Safe torque off (STO) FALSE FALSE FALSE FALSE
With safety function Safely Limited Position (SLP) FALSE FALSE FALSE FALSE
With safety function Safe Direction (SDI) FALSE FALSE FALSE FALSE
protection type Line supply overvoltage
Line supply undervoltage
Overcurrent between output phases and earth
Overheating protection
Short-circuit between motor phases
Against input phase loss in three-phase
Thermal motor protection via the drive by continuous calculation of I²t
Line supply overvoltage
Line supply undervoltage
Overcurrent between output phases and earth
Overheating protection
Short-circuit between motor phases
Against input phase loss in three-phase
Thermal motor protection via the drive by continuous calculation of I²t
Line supply overvoltage
Line supply undervoltage
Overcurrent between output phases and earth
Overheating protection
Short-circuit between motor phases
Against input phase loss in three-phase
Thermal motor protection via the drive by continuous calculation of I²t
Line supply overvoltage
Line supply undervoltage
Overcurrent between output phases and earth
Overheating protection
Short-circuit between motor phases
Against input phase loss in three-phase
Thermal motor protection via the drive by continuous calculation of I²t
Tightening torque 0.8 N.m 0.8 N.m 1.2 N.m 1.2 N.m
Insulation Electrical between power and control Electrical between power and control Electrical between power and control Electrical between power and control
Quantity per set Set of 1 Set of 1 Set of 1 Set of 1
Width 72 mm 72 mm 105 mm 105 mm
Height 143 mm 143 mm 142 mm 142 mm
Depth 121.2 mm 131.2 mm 156.2 mm 156.2 mm
Net weight 0.7 kg 0.8 kg 1.4 kg 1.4 kg
Environment
operating altitude > 1000…2000 m with current derating 1 % per 100 m
<= 1000 m without derating
> 1000…2000 m with current derating 1 % per 100 m
<= 1000 m without derating
> 1000…2000 m with current derating 1 % per 100 m
<= 1000 m without derating
> 1000…2000 m with current derating 1 % per 100 m
<= 1000 m without derating
Operating position Vertical +/- 10 degree Vertical +/- 10 degree Vertical +/- 10 degree Vertical +/- 10 degree
Product certifications NOM
CSA
C-Tick
UL
GOST
RCM
KC
NOM
CSA
C-Tick
UL
GOST
RCM
KC
NOM
CSA
C-Tick
UL
GOST
RCM
KC
NOM
CSA
C-Tick
UL
GOST
RCM
KC
Marking CE CE CE CE
Standards UL 508C
UL 618000-5-1
EN/IEC 61800-5-1
EN/IEC 61800-3
UL 508C
UL 618000-5-1
EN/IEC 61800-5-1
EN/IEC 61800-3
UL 508C
UL 618000-5-1
EN/IEC 61800-5-1
EN/IEC 61800-3
UL 508C
UL 618000-5-1
EN/IEC 61800-5-1
EN/IEC 61800-3
Assembly style With heat sink With heat sink With heat sink With heat sink
electromagnetic compatibility Electrical fast transient/burst immunity test level 4 conforming to EN/IEC 61000-4-4
Electrostatic discharge immunity test level 3 conforming to EN/IEC 61000-4-2
Immunity to conducted disturbances level 3 conforming to EN/IEC 61000-4-6
Radiated radio-frequency electromagnetic field immunity test level 3 conforming to EN/IEC 61000-4-3
Surge immunity test level 3 conforming to EN/IEC 61000-4-5
Voltage dips and interruptions immunity test conforming to EN/IEC 61000-4-11
Electrical fast transient/burst immunity test level 4 conforming to EN/IEC 61000-4-4
Electrostatic discharge immunity test level 3 conforming to EN/IEC 61000-4-2
Immunity to conducted disturbances level 3 conforming to EN/IEC 61000-4-6
Radiated radio-frequency electromagnetic field immunity test level 3 conforming to EN/IEC 61000-4-3
Surge immunity test level 3 conforming to EN/IEC 61000-4-5
Voltage dips and interruptions immunity test conforming to EN/IEC 61000-4-11
Electrical fast transient/burst immunity test level 4 conforming to EN/IEC 61000-4-4
Electrostatic discharge immunity test level 3 conforming to EN/IEC 61000-4-2
Immunity to conducted disturbances level 3 conforming to EN/IEC 61000-4-6
Radiated radio-frequency electromagnetic field immunity test level 3 conforming to EN/IEC 61000-4-3
Surge immunity test level 3 conforming to EN/IEC 61000-4-5
Voltage dips and interruptions immunity test conforming to EN/IEC 61000-4-11
Electrical fast transient/burst immunity test level 4 conforming to EN/IEC 61000-4-4
Electrostatic discharge immunity test level 3 conforming to EN/IEC 61000-4-2
Immunity to conducted disturbances level 3 conforming to EN/IEC 61000-4-6
Radiated radio-frequency electromagnetic field immunity test level 3 conforming to EN/IEC 61000-4-3
Surge immunity test level 3 conforming to EN/IEC 61000-4-5
Voltage dips and interruptions immunity test conforming to EN/IEC 61000-4-11
Environmental class (during operation) Class 3C3 according to IEC 60721-3-3
Class 3S2 according to IEC 60721-3-3
Class 3C3 according to IEC 60721-3-3
Class 3S2 according to IEC 60721-3-3
Class 3C3 according to IEC 60721-3-3
Class 3S2 according to IEC 60721-3-3
Class 3C3 according to IEC 60721-3-3
Class 3S2 according to IEC 60721-3-3
Maximum acceleration under shock impact (during operation) 150 m/s² at 11 ms 150 m/s² at 11 ms 150 m/s² at 11 ms 150 m/s² at 11 ms
Maximum acceleration under vibrational stress (during operation) 10 m/s² at 13…200 Hz 10 m/s² at 13…200 Hz 10 m/s² at 13…200 Hz 10 m/s² at 13…200 Hz
Maximum deflection under vibratory load (during operation) 1.5 mm at 2…13 Hz 1.5 mm at 2…13 Hz 1.5 mm at 2…13 Hz 1.5 mm at 2…13 Hz
Overvoltage category Class III Class III Class III Class III
Regulation loop Adjustable PID regulator Adjustable PID regulator Adjustable PID regulator Adjustable PID regulator
electromagnetic emission Radiated emissions environment 1 category C2 conforming to EN/IEC 61800-3 2…16 kHz shielded motor cable
Conducted emissions with integrated EMC filter environment 1 category C1 conforming to EN/IEC 61800-3 2, 4, 8, 12 and 16 kHz shielded motor cable <5 m
Conducted emissions with integrated EMC filter environment 1 category C2 conforming to EN/IEC 61800-3 2…12 kHz shielded motor cable <5 m
Conducted emissions with integrated EMC filter environment 1 category C2 conforming to EN/IEC 61800-3 2, 4 and 16 kHz shielded motor cable <10 m
Conducted emissions with additional EMC filter environment 1 category C1 conforming to EN/IEC 61800-3 4…12 kHz shielded motor cable <20 m
Conducted emissions with additional EMC filter environment 1 category C2 conforming to EN/IEC 61800-3 4…12 kHz shielded motor cable <50 m
Conducted emissions with additional EMC filter environment 2 category C3 conforming to EN/IEC 61800-3 4…12 kHz shielded motor cable <50 m
Radiated emissions environment 1 category C2 conforming to EN/IEC 61800-3 2…16 kHz shielded motor cable
Conducted emissions with integrated EMC filter environment 1 category C1 conforming to EN/IEC 61800-3 2, 4, 8, 12 and 16 kHz shielded motor cable <5 m
Conducted emissions with integrated EMC filter environment 1 category C2 conforming to EN/IEC 61800-3 2…12 kHz shielded motor cable <5 m
Conducted emissions with integrated EMC filter environment 1 category C2 conforming to EN/IEC 61800-3 2, 4 and 16 kHz shielded motor cable <10 m
Conducted emissions with additional EMC filter environment 1 category C1 conforming to EN/IEC 61800-3 4…12 kHz shielded motor cable <20 m
Conducted emissions with additional EMC filter environment 1 category C2 conforming to EN/IEC 61800-3 4…12 kHz shielded motor cable <50 m
Conducted emissions with additional EMC filter environment 2 category C3 conforming to EN/IEC 61800-3 4…12 kHz shielded motor cable <50 m
Radiated emissions environment 1 category C2 conforming to EN/IEC 61800-3 2…16 kHz shielded motor cable
Conducted emissions with integrated EMC filter environment 1 category C1 conforming to EN/IEC 61800-3 2, 4, 8, 12 and 16 kHz shielded motor cable <5 m
Conducted emissions with additional EMC filter environment 1 category C1 conforming to EN/IEC 61800-3 4…12 kHz shielded motor cable <20 m
Conducted emissions with additional EMC filter environment 1 category C2 conforming to EN/IEC 61800-3 4…12 kHz shielded motor cable <50 m
Conducted emissions with additional EMC filter environment 2 category C3 conforming to EN/IEC 61800-3 4…12 kHz shielded motor cable <50 m
Conducted emissions with integrated EMC filter environment 1 category C2 conforming to EN/IEC 61800-3 4…16 kHz shielded motor cable <5 m
Conducted emissions with integrated EMC filter environment 1 category C2 conforming to EN/IEC 61800-3 2, 4, 8, 12 and 16 kHz shielded motor cable <10 m
Radiated emissions environment 1 category C2 conforming to EN/IEC 61800-3 2…16 kHz shielded motor cable
Conducted emissions with integrated EMC filter environment 1 category C1 conforming to EN/IEC 61800-3 2, 4, 8, 12 and 16 kHz shielded motor cable <5 m
Conducted emissions with additional EMC filter environment 1 category C1 conforming to EN/IEC 61800-3 4…12 kHz shielded motor cable <20 m
Conducted emissions with additional EMC filter environment 1 category C2 conforming to EN/IEC 61800-3 4…12 kHz shielded motor cable <50 m
Conducted emissions with additional EMC filter environment 2 category C3 conforming to EN/IEC 61800-3 4…12 kHz shielded motor cable <50 m
Conducted emissions with integrated EMC filter environment 1 category C2 conforming to EN/IEC 61800-3 4…16 kHz shielded motor cable <5 m
Conducted emissions with integrated EMC filter environment 1 category C2 conforming to EN/IEC 61800-3 2, 4, 8, 12 and 16 kHz shielded motor cable <10 m
vibration resistance 1 gn (f = 13…200 Hz) conforming to EN/IEC 60068-2-6
1.5 mm peak to peak (f = 3…13 Hz) – drive unmounted on symmetrical DIN rail – conforming to EN/IEC 60068-2-6
1 gn (f = 13…200 Hz) conforming to EN/IEC 60068-2-6
1.5 mm peak to peak (f = 3…13 Hz) – drive unmounted on symmetrical DIN rail – conforming to EN/IEC 60068-2-6
1 gn (f = 13…200 Hz) conforming to EN/IEC 60068-2-6
1.5 mm peak to peak (f = 3…13 Hz) – drive unmounted on symmetrical DIN rail – conforming to EN/IEC 60068-2-6
1 gn (f = 13…200 Hz) conforming to EN/IEC 60068-2-6
1.5 mm peak to peak (f = 3…13 Hz) – drive unmounted on symmetrical DIN rail – conforming to EN/IEC 60068-2-6
shock resistance 15 gn conforming to EN/IEC 60068-2-27 for 11 ms 15 gn conforming to EN/IEC 60068-2-27 for 11 ms 15 gn conforming to EN/IEC 60068-2-27 for 11 ms 15 gn conforming to EN/IEC 60068-2-27 for 11 ms
relative humidity 5…95 % without condensation conforming to IEC 60068-2-3
5…95 % without dripping water conforming to IEC 60068-2-3
5…95 % without condensation conforming to IEC 60068-2-3
5…95 % without dripping water conforming to IEC 60068-2-3
5…95 % without condensation conforming to IEC 60068-2-3
5…95 % without dripping water conforming to IEC 60068-2-3
5…95 % without condensation conforming to IEC 60068-2-3
5…95 % without dripping water conforming to IEC 60068-2-3
Noise level 0 dB 0 dB 45 dB 45 dB
Pollution degree 2 2 2 2
Ambient air transport temperature -25…70 °C -25…70 °C -25…70 °C -25…70 °C
ambient air temperature for operation -10…40 °C without derating
40…60 °C with current derating 2.2 % per °C
-10…40 °C without derating
40…60 °C with current derating 2.2 % per °C
-10…50 °C without derating
50…60 °C with current derating 2.2 % per °C
-10…50 °C without derating
50…60 °C with current derating 2.2 % per °C
Ambient air temperature for storage -25…70 °C -25…70 °C -25…70 °C -25…70 °C
Packing Units
Unit Type of Package 1 PCE PCE PCE PCE
Number of Units in Package 1 1 1 1 1
Package 1 Height 12.600 cm 11.700 cm 23 cm 20.000 cm
Package 1 Width 20.000 cm 19.000 cm 20 cm 18.000 cm
Package 1 Length 18.700 cm 19.500 cm 21.5 cm 20.000 cm
Package 1 Weight 1.035 kg 1.118 kg 1.716 kg 1.753 kg
Unit Type of Package 2 P06 P06 P06 P06
Number of Units in Package 2 45 45 30 30
Package 2 Height 75.000 cm 75.000 cm 75 cm 75.000 cm
Package 2 Width 60.000 cm 60.000 cm 60 cm 60.000 cm
Package 2 Length 80.000 cm 80.000 cm 80 cm 80.000 cm
Package 2 Weight 59.530 kg 63.085 kg 64.84 kg 65.950 kg
Contractual warranty
Warranty 18 months 18 months 18 months 18 months

 

Weight N/A
Dimensions N/A

Related products