Acti9 – Disbo iC60H – Miniature Circuit Breaker – Schneider Circuit Breakers

$ 68.86$ 77.88

SKU: N/A

This Acti9 iC60H is a multistandard low voltage miniature circuit breaker (MCB) with double tunnel terminals. Class-2 insulation : continuous safety for operators and unqualified personnel For DIN Rail Full coordination with Acti 9 range RCDs and Compact NSX MCCBs VisiSafe : for safe operation and maintenance work on circuits VisiTrip : detects faulty Miniature Circuit-Breaker outgoers quickly and reduces intervention time Its VisiSafe green strip guarantees the physical opening of the contacts to allow downstream maintenance. Its fast closing mechanism independent of manual operation improves its service life. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ui rated insulation voltage is 500VAC. Its limitation class 3 (according to EN/IEC60898-1) improves downstream circuit protection cost. The product can be clipped on a DIN rail. Its width is 2 pitches of 9mm. Pollution degree is 3. The product colour is white (RAL9003). The dimensions are (W) 18mm x (H) 85mm x (D) 78.5mm. The weight is 0.125kg. It has an IP20 degree of protection (as per IEC/EN 60529) on its terminals. The operating temperature is -35°C to 70°C. The storage temperature is -40°C to 85°C.

 

Specifications

Main
Part  Number A9F54102 A9F54104
Range Acti9 Acti9
Product name Disbo iC60 Disbo iC60
Product or component type Miniature circuit-breaker Miniature circuit-breaker
device short name IC60H IC60H
Poles description 1P 1P
Number of protected poles 1 1
[In] rated current 2:00 AM 4:00 AM
Network type AC AC
Trip unit technology Thermal-magnetic Thermal-magnetic
Curve code C C
Breaking capacity 70 kA Icu at 12…60 V AC 50/60 Hz conforming to EN/IEC 60947-2 70 kA Icu at 12…60 V AC 50/60 Hz conforming to EN/IEC 60947-2
70 kA Icu at 100…133 V AC 50/60 Hz conforming to EN/IEC 60947-2 70 kA Icu at 100…133 V AC 50/60 Hz conforming to EN/IEC 60947-2
70 kA Icu at 220…240 V AC 50/60 Hz conforming to EN/IEC 60947-2 70 kA Icu at 220…240 V AC 50/60 Hz conforming to EN/IEC 60947-2
20 kA Icu at 12…60 V DC conforming to EN/IEC 60947-2 20 kA Icu at 12…60 V DC conforming to EN/IEC 60947-2
15 kA Icu at 60…72 V DC conforming to EN/IEC 60947-2 15 kA Icu at 60…72 V DC conforming to EN/IEC 60947-2
10000 A Icn at 240 V AC 50/60 Hz conforming to EN/IEC 60898-1 10000 A Icn at 240 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilisation category Category A conforming to EN/IEC 60947-2 Category A conforming to EN/IEC 60947-2
Complementary
Network frequency 50/60 Hz 50/60 Hz
[Ue] rated operational voltage 240 V AC 50/60 Hz 240 V AC 50/60 Hz
magnetic tripping limit 8 x In +/- 20 % 8 x In +/- 20 %
[Ics] rated service breaking capacity 70 kA 100 % conforming to EN/IEC 60947-2 – 12…60 V AC 50/60 Hz 70 kA 100 % conforming to EN/IEC 60947-2 – 12…60 V AC 50/60 Hz
70 kA 100 % conforming to EN/IEC 60947-2 – 100…133 V AC 50/60 Hz 70 kA 100 % conforming to EN/IEC 60947-2 – 100…133 V AC 50/60 Hz
70 kA 100 % conforming to EN/IEC 60947-2 – 220…240 V AC 50/60 Hz 70 kA 100 % conforming to EN/IEC 60947-2 – 220…240 V AC 50/60 Hz
7500 A 75 % conforming to EN/IEC 60898-1 – 240 V AC 50/60 Hz 7500 A 75 % conforming to EN/IEC 60898-1 – 240 V AC 50/60 Hz
20 kA 100 % conforming to EN/IEC 60947-2 – 12…48 V DC 20 kA 100 % conforming to EN/IEC 60947-2 – 12…48 V DC
10 kA 100 % conforming to EN/IEC 60947-2 – 72 V DC 10 kA 100 % conforming to EN/IEC 60947-2 – 72 V DC
Limitation class 3 conforming to EN/IEC 60947-2 3 conforming to EN/IEC 60947-2
[Ui] rated insulation voltage 500 V AC 50/60 Hz conforming to EN/IEC 60947-2 500 V AC 50/60 Hz conforming to EN/IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV conforming to EN/IEC 60947-2 6 kV conforming to EN/IEC 60947-2
Contact position indicator Yes Yes
Control type Toggle Toggle
Local signalling Trip indicator Trip indicator
Mounting mode Clip-on Clip-on
Mounting support Rail Rail
9 mm pitches 2 2
Height 85 mm 85 mm
Width 18 mm 18 mm
Depth 78.5 mm 78.5 mm
Product weight 0.125 kg 0.125 kg
Colour White White
Mechanical durability 20000 cycles 20000 cycles
Electrical durability 10000 cycles 10000 cycles
Provision for padlocking Padlockable Padlockable
Connections – terminals Single terminal (top or bottom) 1…25 mm² rigid Single terminal (top or bottom) 1…25 mm² rigid
Single terminal (top or bottom) 1…16 mm² flexible Single terminal (top or bottom) 1…16 mm² flexible
Wire stripping length 14 mm for top or bottom connection 14 mm for top or bottom connection
Tightening torque 2 N.m top or bottom 2 N.m top or bottom
Earth-leakage protection Separate block Separate block
Environment
Standards EN/IEC 60947-2 EN/IEC 60947-2
EN/IEC 60898-1 EN/IEC 60898-1
IP degree of protection IP20 conforming to IEC 60529 IP20 conforming to IEC 60529
Pollution degree 3 conforming to EN/IEC 60947-2 3 conforming to EN/IEC 60947-2
Tropicalisation 2 conforming to IEC 60068-1 2 conforming to IEC 60068-1
Relative humidity 95 % at 55 °C 95 % at 55 °C
Ambient air temperature for operation -35…70 °C -35…70 °C
Ambient air temperature for storage -40…85 °C -40…85 °C
Packing Units
Unit Type of Package 1 PCE PCE
Number of Units in Package 1 1 1
Package 1 Height 1.8 cm 7.000 cm
Package 1 Width 7.5 cm 1.800 cm
Package 1 Length 9.0 cm 9.000 cm
Package 1 Weight 111.0 g 110.000 g
Unit Type of Package 2 BB1 BB1
Number of Units in Package 2 12 12
Package 2 Height 8.0 cm 8.000 cm
Package 2 Width 9.8 cm 9.500 cm
Package 2 Length 22.0 cm 22.000 cm
Package 2 Weight 1.394 kg 1.383 kg
Unit Type of Package 3 S03 S03
Number of Units in Package 3 132 132
Package 3 Height 30.0 cm 30.000 cm
Package 3 Width 30.0 cm 30.000 cm
Package 3 Length 40.0 cm 40.000 cm
Package 3 Weight 15.821 kg 15.827 kg
Contractual warranty
Warranty 18 months 18 months
Weight N/A
Dimensions N/A
Amp a

2, 4