| Input Number of phases | 3 AC |
| Input Line voltage | 380 ... 480 V +10% -20% |
| Input Line frequency | 47 ... 63 Hz |
| Input Rated current (LO) | 221.00 A |
| Input Rated current (HO) | 207.00 A |
| Output Number of phases | 3 AC |
| Output Rated voltage | 400V IEC / 480V NEC |
| Output Rated power (LO) | 132.00 kW (150.00 hp) |
| Output Rated power (HO) | 110.00 kW (125.00 hp) |
| Output Rated current (LO) | 237.00 A |
| Output Rated current (HO) | 201.00 A |
| Output Rated current (IN) | 237.00 A |
| Output Max. output current | 402.00 A |
| Output Pulse frequency | 4 kHz |
| Output frequency for vector control | 0 ... 240 Hz |
| Output frequency for V/f control | 0 ... 550 Hz |
| Low Overload (LO) capability | 150% base load current IL for 3 s, then 110% IL for 57 s in a 300 s cycle time |
| High Overload (HO) capability | 200% base load current IH for 3 s, then 150% IH for 57 s in a 300 s cycle time |
| Standard digital inputs Number | 6 |
| Standard digital inputs Switching level: 0→1 | 11 V |
| Standard digital inputs Switching level: 1→0 | 5 V |
| Standard digital inputs Max. inrush current | 15 mA |
| Fail-safe digital inputs Number | 1 |
| Digital outputs Number as relay changeover contact | 1 |
| Digital outputs Output (resistive load) relay | DC 30 V, 0.5 A |
| Digital outputs Number as transistor | 1 |
| Digital outputs Output (resistive load) transistor | DC 30 V, 0.5 A |
| Analog / digital inputs Number | 1 (Differential input) |
| Analog / digital inputs Resolution | 10 bit |
| Switching threshold as digital input 0-1 | 4 V |
| Switching threshold as digital input 1-0 | 1.6 V |
| Analog outputs Number | 1 (Non-isolated output) |
| PTC/KTY interface | 1 motor temperature sensor input (PTC, KTY, Thermo-Click), accuracy ±5 °C |
| V/f linear / square-law / parameterizable control | Yes |
| V/f with flux current control (FCC) | Yes |
| V/f ECO linear / square-law | Yes |
| Sensorless vector control | Yes |
| Vector control, with sensor | No |
| Encoderless torque control | No |
| Torque control, with encoder | No |
| Power factor λ | 0.90 ... 0.95 |
| Offset factor cos φ | 0.99 |
| Efficiency η | 0.99 |
| Sound pressure level (1m) | 68 dB |
| Power loss | 2,920.0 W |
| Filter class (integrated) | Class A |
| Communication protocol | USS/MODBUS RTU |
| Cooling method | Air cooling using an integrated fan |
| Cooling air requirement | 0.153 m³/s (5.403 ft³/s) |
| Installation altitude | 1,000 m (3,280.84 ft) |
| Operation temperature | -20 ... 40 °C (-4 ... 104 °F) |
| Transport temperature | -40 ... 70 °C (-40 ... 158 °F) |
| Storage temperature | -25 ... 55 °C (-13 ... 131 °F) |
| Max. operation relative humidity | 95% RH, condensation not permitted |
| Signal cable conductor cross-section | 0.15 ... 1.50 mm² (AWG 24 ... AWG 16) |
| Line side connection version | screw-type terminal |
| Line side conductor cross-section | 35.00 ... 120.00 mm² (AWG 2 ... AWG -3) |
| Motor end connection version | screw-type terminals |
| Motor end conductor cross-section | 35.00 ... 120.00 mm² (AWG 2 ... AWG -3) |
| DC link (for braking resistor) version | screw-type terminals |
| DC link (for braking resistor) conductor cross-section | 35.00 ... 120.00 mm² (AWG 2 ... AWG -3) |
| Max. line length | 10 m (32.81 ft) |
| PE connection type | Screw-type terminals |
| Max. motor cable length shielded | 300 m (984.25 ft) |
| Max. motor cable length unshielded | 450 m (1,476.38 ft) |
| Degree of protection | IP20 / UL open type |
| Frame size | FSF |
| Compliance with standards | CE, CUL, UL, KC, EAC, C-Tick (RCM) |
| CE marking directives | EMC Directive 2004/108/EC, Low-Voltage Directive 2006/95/EC |
| Efficiency class | IE2 |
| Physical Weight (kg) | 66 |
| Dimensions L x W x H (cm) | 76 x 40 x 58.5 |