Pepperl+Fuchs KFD2-STC5-Ex2 SMART Transmitter Power Supply

USD 124.08

Two-channel SIL 2 isolated barrier for 2-wire/3-wire SMART 0/4-20mA transmitters in hazardous areas, offering galvanic isolation and HART support.

SKU PEPPERL-FUCHS-KFD2-STC5-EX2 Category
Top Brands > PEPPERL+FUCHS > PEPPERL+FUCHS SMART Transmitter Power Supply

Pepperl+Fuchs KFD2-STC5-Ex2 SMART Transmitter Power Supply

Model Identifier KFD2-STC5-Ex2
Official Part Number KFD2-STC5-EX2
GTIN Standard 4050143061211

Technical Overview

Two-channel SIL 2 isolated barrier for 2-wire/3-wire SMART 0/4-20mA transmitters in hazardous areas, offering galvanic isolation and HART support.

Key Features

  • 2-channel isolated barrier
  • 24 V DC supply (Power Rail)
  • Input for 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources
  • Output 0/4 mA ... 20 mA current sink/current source
  • Terminals with test points for HART communicators
  • Up to SIL 2 (SC 3) according to IEC/EN 61508
  • Galvanic isolation between hazardous and safe areas
  • Supports HART communication
  • DIN rail mounting

2-channel isolated barrier with 24 V DC supply, supporting 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources with 0/4 mA to 20 mA current sink/source output.

Technical Specification Matrix

ParameterValue
Signal typeAnalog input
Safety Integrity Level (SIL)SIL 2 (SC 3) acc. to IEC/EN 61508
Supply voltage18 ... 30 V DC
Rated insulation voltage50 V AC (functional insulation)
Power dissipation≤ 1.4 W at maximum load
Power consumption≤ 2.6 W at maximum load
Input signal0/4 ... 20 mA
Output signal0/4 ... 20 mA (current sink/current source)
Ambient temperature-20 ... 60 °C (-4 ... 140 °F)
Degree of protectionIP20
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001
EU-type examination certificateCML 17 ATEX 2031X
UL approvalE106378
Physical Weight (kg)0.17
Dimensions L x W x H (cm)11.5 x 2 x 12.4

Industrial Applications

1. Hazardous Area Process Monitoring in Chemical Plants

The KFD2-STC5-Ex2 acts as a crucial interface for monitoring critical process variables like temperature, pressure, and flow in hazardous zones of chemical processing plants where potentially explosive atmospheres are present. Its intrinsic safety design ensures that field devices in these areas are powered and monitored without risk of ignition.

Problem Solved

Provides a safe and reliable method for transferring analog sensor data (0/4-20mA with HART) from 2-wire and 3-wire SMART transmitters in Zone 1/Zone 0 hazardous areas to control systems in the safe area, preventing explosions through intrinsic safety (SIL 2 rated) and galvanic isolation.

Intrinsic safetyHazardous areaChemical processingSMART transmitter4-20mAHART communicationGalvanic isolationSIL 2

2. Remote Wellhead Monitoring in Oil & Gas Operations

In oil and gas production, wellheads are often located in remote, hazardous environments. This device facilitates the safe and efficient collection of critical wellhead data, such as pressure and temperature, by acting as an isolated barrier between field sensors and the central control system.

Problem Solved

Enables remote monitoring of analog sensor signals (0/4-20mA from SMART transmitters) from hazardous oil and gas wellhead locations, ensuring intrinsic safety (SIL 2) and reliable signal transmission over long distances. The HART capability allows for remote diagnostics and calibration, reducing the need for personnel in dangerous zones. Its -20 to 60°C operating range suits harsh outdoor conditions.

Oil & gasWellhead monitoringHazardous locationSMART sensor4-20mAIntrinsic safetySIL 2Remote diagnosticsHART

3. Explosion-Protected Process Control in Pharmaceutical Manufacturing

Pharmaceutical manufacturing often involves processes with flammable solvents or dusts, necessitating rigorous explosion protection alongside precise process control. This isolated barrier allows for the safe integration of critical sensors in such environments.

Problem Solved

Facilitates precise and safe process control in pharmaceutical plants with potentially explosive atmospheres (e.g., due to solvents or dusts). It provides intrinsic safety (SIL 2) for 2-wire/3-wire SMART analog transmitters measuring parameters like pH or flow, ensuring accurate 0/4-20mA signal transmission to the control system while maintaining a safe operating environment.

Pharmaceutical manufacturingExplosion protectionIntrinsic safetyProcess controlSMART transmitter4-20mASIL 2Cleanroom applications
Select your currency