SICK 1069571 STR1-SAMM0AC8 RFID Safety Switch with Actuator

USD 161.72

STR1-SAMM0AC8 includes a mini actuator, universal RFID coding, two OSSDs, a complementary AUX output, safe series connection and a 0.2 m M12 eight-pin lead.

SKU SICK-1069571 Category
SICK Safety Switches

SICK STR1-SAMM0AC8 RFID Safety Switch with Actuator

BrandSICK
Model IdentifierSTR1-SAMM0AC8
Official Part Number1069571

Technical Overview

The SICK STR1-SAMM0AC8 is a non-contact RFID safety switch supplied with a mini actuator and universally coded at the low coding level. Two self-monitoring semiconductor safety outputs accompany a complementary auxiliary output for ordinary indication. Three active sensor surfaces and five actuation directions accommodate different guard arrangements. Frontal assured switch-on distance is 14 mm from −10 to +70 °C, reducing to 10 mm from −30 to −10 °C; assured frontal switch-off distance is 28 mm. Safe series connection is supported through T-connectors without diagnostics or Flexi Loop with diagnostics. The VISTAL housing provides IP67/IP69K protection and a 0.2 m PVC lead with an M12 eight-pin plug. Operation below −10 °C requires serial-number series 1825**** or higher.

Universally coded RFID safety switch with mini actuator, two OSSDs, complementary ordinary AUX output and a 0.2 m M12 eight-pin lead.

Key Features

  • RFID non-contact safety switch supplied with mini actuator
  • Universally coded; low coding level; Type 4 to EN ISO 14119
  • Two self-monitoring OSSD safety outputs; one complementary non-safe AUX output
  • Three active surfaces: top, left and right; five actuation directions
  • Frontal assured switch-on: 14 mm at −10 to +70 °C; 10 mm at −30 to −10 °C
  • Frontal assured switch-off distance: 28 mm
  • SIL 3 to IEC 61508; Category 4 / PL e to EN ISO 13849
  • Safe series connection: T-connector without diagnostics or Flexi Loop with diagnostics
  • 24 V DC nominal; 0.2 m PVC lead and M12 eight-pin plug
  • VISTAL housing; IP67/IP69K; below −10 °C only for serial-number series 1825**** or higher

Monitor a guard-mounted mini actuator using two self-monitoring OSSDs, with supported series arrangements and a separate auxiliary indication output.

Technical Specification Matrix

ParameterValue
Functional principleNon-contact RFID safety switch
System partSensor supplied with mini actuator
CodingUniversally coded; low coding level to EN ISO 14119
TypeType 4 to EN ISO 14119
Safe outputsTwo self-monitoring semiconductor outputs, OSSDs
Auxiliary outputOne non-safe AUX output; switching behavior complementary to OSSDs
Frontal assured switch-on distance Sao14 mm at −10 to +70 °C; 10 mm at −30 to −10 °C; lower-temperature use subject to serial-number condition
Frontal assured switch-off distance Sar28 mm
Side assured switch-on distance Sao9 mm for flat/mini actuator at active side surface; see manufacturer approach curves and operating instructions
Lateral approach clearanceManufacturer typical minimum gap for lateral movement: 4 mm at side surface; 10 mm at front surface, avoiding early triggering in side preparation areas
Active sensor surfacesThree: top, left and right
Actuation directionsFive
Safety integrity levelSIL 3, IEC 61508
Safety category and performance levelCategory 4 / PL e, EN ISO 13849
PFHD5.1 × 10^-9 per hour
Mission time20 years, EN ISO 13849
Safe state in faultAt least one safety-related OSSD is in the OFF state
Safe series connectionT-connector without diagnostics; Flexi Loop with diagnostics
Power supply24 V DC nominal; permitted range 19.2–28.8 V DC
Current consumption50 mA
Output current≤100 mA
Protection classIII, IEC 61140; cULus Class 2
Response time40 ms; downstream safety switches increase system response time in a safe series connection; further timings in operating instructions
Release time100 ms response on approach to enable zone
Risk time80 ms detection of internal or external faults, including output short or cross circuits; detailed conditions in operating instructions
Switch-on time2.5 s for one sensor after supply application; add 0.1 s for each sensor in a safe series connection
Connection0.2 m cable with M12 eight-pin plug
Maximum connecting-cable length≤200 m
Cable materialPVC jacket; copper conductors; 5.5 mm diameter; 0.12 mm² conductor cross-section
Cable bend radiusFixed installation >8 × cable diameter; moving cable >12 × cable diameter
Coupling nut materialNickel-plated zinc die-cast
Pin assignment1=AUX, non-safe; 2=24 V supply; 3=not connected; 4=enable input OSSD 2; 5=OSSD 1; 6=OSSD 2; 7=0 V supply; 8=enable input OSSD 1
IndicationLED diagnostic and status indications
Housing materialVISTAL
IP ratingIP67, IEC 60529; IP69K, ISO 20653
Operating temperature−30 to +70 °C only for serial-number series 1825**** or higher; otherwise −10 to +70 °C; serial number on switch or data matrix code
Storage temperature−30 to +70 °C
Vibration resistance10–55 Hz, 1 mm, IEC 60068-2-6
Shock resistance30 g, 11 ms, IEC 60068-2-27
EMCEN IEC 61326-3-1; EN IEC 60947-5-2; EN IEC 60947-5-3; EN 300330 V2.1.1

Industrial Applications

1. Monitoring closure of a movable machine guard

A movable guard can carry the supplied mini actuator opposite a fixed RFID sensor, with the two OSSDs connected to an appropriate safe evaluation unit. Universal coding and the documented frontal operating distances define the actuator relationship. The safety function uses the evaluated OSSD states; guard geometry, overall stopping time and the serial-number temperature condition remain part of the machine-specific safety design.

Problem Solved

Non-contact actuator detection provides two self-monitoring safety signals for the guard evaluation, supporting a closure-monitoring function without a mechanically operated switch contact at the sensing point.

Guard closure Two OSSDs Mini actuator

2. Connecting several access guards in a monitored series

A machine with several movable access guards can use the documented safe series arrangements to connect RFID switches to a safe evaluation system. T-connectors provide series connection without diagnostics, while Flexi Loop supports diagnostics. System design accounts for the added downstream response time and the specified startup-time addition for each sensor, alongside the required guard and stopping behavior.

Problem Solved

Supported series arrangements connect multiple guard signals to the safety evaluation, while the diagnostic option and documented timing additions give the designer concrete system-integration choices.

Multiple guards Safe series Flexi Loop diagnostics

3. Displaying guard condition in ordinary machine supervision

A supervisory controller can read the separate AUX output to display guard condition during machine operation or maintenance. Its switching behavior is complementary to the OSSDs, and the manufacturer explicitly identifies it as non-safe. LED status and diagnostic indications provide local information; the safety function continues to use the two OSSDs and its safe evaluation circuit.

Problem Solved

A separate ordinary indication signal gives machine supervision a guard-condition reference, supporting operator displays and maintenance observation while the dedicated OSSDs serve the safety evaluation.

Guard indication Non-safe AUX Local LEDs
Select your currency