SICK 1091611 FC1A-DZ2A1A CANopen IO-Link FlexChain Host

USD 223.34

FlexChain host with CANopen, IO-Link V1.1, two guest ports, USB/SOPAS ET configuration, zone and logic functions, 24 V supply and IP65/IP67.

SKU SICK-1091611 Category
SICK Automation Light Grids

SICK FC1A-DZ2A1A CANopen IO-Link FlexChain Host

BrandSICK
Model IdentifierFC1A-DZ2A1A
Official Part Number1091611

Technical Overview

The SICK FC1A-DZ2A1A is a FlexChain Host for integrating compatible photoelectric sensors and light-grid devices into an evaluated sensing system. Two cabled M8 guest ports connect the sensing branches, while CANopen, one configurable I/O and Q1/IO-Link connect the host to external control. USB and SOPAS ET support sensor and interface parameterization, zone definition, measurement functions, logic and diagnostics. IO-Link V1.1 operates at COM3 with 32-byte process data, and CANopen supports 50 kbit/s to 1 Mbit/s. The 24 V DC host has an ABS housing, IP65/IP67 protection and a system-dependent response no greater than 35 ms. Two FlexChain terminators are supplied.

FlexChain Host with CANopen, IO-Link V1.1, two M8 guest ports, USB/SOPAS ET configuration, zone definition and logic functions.

Key Features

  • FlexChain Host for compatible photoelectric sensing and light-grid guests
  • Two cabled M8 four-pin female guest ports, A and B
  • CANopen interface, 50 kbit/s to 1 Mbit/s
  • IO-Link V1.1 COM3, 230.4 kbit/s; 32-byte process data; cycle ≥2.3 ms
  • CANopen + one I/O + one Q/IO-Link; Q2 and In1 share one connection
  • USB/SOPAS ET configuration, sensor/interface parameterization and diagnostics
  • Zone definition, measurement functions and Base logics Smart Task
  • System-dependent response ≤35 ms; initialization <1 s
  • 24 V DC ±20%; 600 mA at maximum guest count; output ≤100 mA
  • ABS housing; IP65/IP67; −25 to +50 °C operation; two terminators supplied

Evaluate connected FlexChain sensing branches with configurable zones and logic, then pass process information to external control over CANopen or IO-Link.

Technical Specification Matrix

ParameterValue
Product typeFlexChain Host
Supported sensing systemFlexChain sender/receiver, photoelectric retro-reflective and proximity sensors, and light-grid system
ConfigurationUSB connection with SICK SOPAS ET
Parameterization functionsSensor parameterization; zone definition; measurement and logic functions; interface parameterization; diagnostics
Smart TaskBase logics
SynchronizationCable
Response time≤35 ms, depending on system configuration
IO-LinkV1.1; COM3, 230.4 kbit/s
IO-Link cycle time≥2.3 ms
Process data32 bytes
CANopen50 kbit/s to 1 Mbit/s
Inputs/outputsCANopen + one I/O + one Q (IO-Link)
Digital outputsTwo, Q1 and Q2; Q2/In1 shared
Digital inputOne, In1
Output current≤100 mA
Output loadCapacitive 100 µF; inductive 1 H
Power supply24 V DC ±20%; reverse-polarity protected; operate in short-circuit-protected network, maximum 8 A
Current consumption600 mA at 24 V with maximum number of guests
Initialization time<1 s
Guest portsPort A and B: cable with M8 four-pin female connector, 1.5 m
PLC connectionCable with M12 five-pin male connector, 0.5 m
CANopen connectionCable with M12 five-pin male connector, 0.3 m
USB connectionUSB Micro-B service/configuration connection, as shown in connection diagram
PLC pin assignment1 BN=L+; 2 WH=Q2/In1; 3 BU=M; 4 BK=Q1/C; 5 GY=not connected
CANopen pin assignment1 BN=not connected; 2 WH=not connected; 3 BU=GND; 4 VT=CAN1_H; 5 OG=CAN1_L
Port A/B pin assignment1 BN=CAN_H; 2 WH=CAN_L; 3 BU=+12 V; 4 BK=GND
USB pin assignment1 WH=+5 V; 2 BU=Data−; 3 BK=Data+; 4=not connected; 5 GY=GND
Housing materialABS plastic
IP ratingIP65 / IP67
Circuit protectionSupply reverse-polarity protection; output Q short-circuit protection; interference pulse suppression
Protection classIII
Operating temperature−25 to +50 °C
Storage temperature−25 to +70 °C
Shock resistanceSingle 30 g, 11 ms, six per axis; continuous 25 g, 6 ms, 1,000 per axis
Vibration resistanceSinusoidal 20–2,000 Hz, 10 g, three hours per axis
EMCEN 61000-6-2 and EN 61000-6-3
Items suppliedOne FlexChain Host, one Quick Start Guide and two FlexChain terminators, 2119481
Mounting drawing82.6 mm mounting-hole spacing; two Ø5.5 mm holes
Physical Weight (kg)0.17

Industrial Applications

1. Combining sensing conditions across a transfer station

A transfer station can connect compatible FlexChain sensing guests to the host branches and define zones associated with the material path. Parameterized logic combines the connected sensing conditions, and CANopen or the documented local I/O carries process information to external sequencing. Commissioning establishes the guest arrangement and zone definitions, accounting for the system-dependent response and the individual guest sensing characteristics.

Problem Solved

A host-level zone and logic configuration gives external transfer control an evaluated process reference, helping coordinate material movement across multiple connected sensing locations.

Zone logic Connected guests CANopen

2. Changing sensor settings for a production recipe

A production station handling different component formats can use USB and SOPAS ET to establish the corresponding sensor parameters and zone definitions in its FlexChain arrangement. The host also provides interface and measurement-function parameterization so that the evaluated conditions match the intended process setup. Commissioning checks each recipe against representative components and the capabilities of its connected sensing guests before production begins.

Problem Solved

Central configuration of the sensing arrangement helps commissioning align sensor settings and evaluated zones with the production recipe, reducing repeated adjustment at separate sensing locations.

Recipe setup SOPAS ET Sensor parameters

3. Diagnosing a distributed sensing arrangement

A maintenance workstation can connect through the host USB interface and use SOPAS ET diagnostics while presenting reference targets to the connected FlexChain guests. The host configuration and diagnostic functions help staff relate observed conditions to the relevant sensing branch or configured zone. The maintenance procedure compares those observations with external control readings and the documented wiring of the installed system.

Problem Solved

Host-accessible diagnostics help maintenance relate an unexpected process condition to the connected sensing arrangement, supporting fault investigation without relying only on the final machine input state.

System diagnostics USB access Reference targets